14 AWG 7C Bare Copper Unshielded PVC Sumflex® RVFV-K FB 0.6/1kV Eca CPR Metal Armored Cable
Where are we? 4 Continents 8 Countries
Got any Questions?
Speak with a real person who will go out of their way to help you!
Call Us: 1-516-482-6313Text Us: 1-516-703-3460
Chat
Live Chat: Bottom Right Corner!
Email Us
info@nassaunationalcable.com
Quick Support
Product Information
Specification
14 AWG 7C Bare Copper Unshielded PVC Sumflex® RVFV-K FB 0.6/1kV Eca CPR Metal Armored Cable
Allowable Ampacity for 14 AWG 7C Bare Copper Unshielded PVC Sumflex® RVFV-K FB 0.6/1kV Eca CPR Metal Armored Cable: 100 Amps
Application:
RVFV-K FB CPR cables meet the criteria for the classification of construction products according to CPR Regulation 305/2011 and the EN 50575 standard, indicated for the transport and distribution of low voltage electrical energy. Recommended for industrial connections, connections, indoor and outdoor distribution. Excellent protection against the action of rodents and excellent resistance to compression.
Suitable for the following installations:
- ITC-BT 07 Underground networks for low voltage distribution
- ITC-BT 09 Underground power networks for outdoor lighting installations
- ITC-BT 11 Electrical power distribution networks. underground connections
- ITC-BT 20 Interior or reception installations
- ITC-BT 30 Installations in premises with special characteristics
Also Known as:
Sumflex Cable, Sumflex® RVFV-K Cable, Armored Cable, SumCab Cable, Electrical Cable, Flexible Cable
Design:
• Conductor Flexible electrolytic copper (Class 5) according to UNE-EN 60228, EN 60228 and IEC 60228 Insulation
• Cross-linked polyethylene (XLPE) type DIX 3 according to UNE 21123, HD 603 S1 and IEC 60502-1 Conductor
• Identification according to HD 308 S2 or EN 50334
• Internal PVC seat/cover Metal armor with double steel strip
• Polyvinyl chloride DMV-18 type according to UNE 21123, UNE-HD 603-1 and IEC 60502
• Black color
Technical Data:
Rated voltage 0.6/1 kV Test
voltage 3,500 V AC
Maximum temperature 90 °C (250 °C for 5 seconds in the event of a short circuit)
Minimum bending radius 10 x External diameter in fixed installation Service
temperature -15 °C to +90 °C
Specification:
AWG Size: 14
Number of Conductor: 7
Conductor: Bare Copper
Conductor x Section: 7G 2.50 mm²
Resistance at 20°C: 7.98 ohm/km
Outside diameter approx: 16.8 mm
Rated Voltage: 450/750 V
Weight: 329.26 lbs/MFT
*Data provided on this page is subject to change based on different manufacturers' variances
** Images are for display purposes only refer to Product Technical Details for accurate information on the product.
In the case the material only comes in a predetermined color or doesn’t come with any color
Reviews