14 AWG 2C Bare Copper Braid Shielded PVC Sumflex® RC4V-K 0.6/1kV Eca CPR Screen Cable
Where are we? 4 Continents 8 Countries
Got any Questions?
Speak with a real person who will go out of their way to help you!
Call Us: 1-516-482-6313Text Us: 1-516-703-3460
Chat
Live Chat: Bottom Right Corner!
Email Us
info@nassaunationalcable.com
Quick Support
Product Information
Specification
14 AWG 2C Bare Copper Braid Shielded PVC Sumflex® RC4V-K 0.6/1kV Eca CPR Screen Cable
Allowable Ampacity for 14 AWG 2C Bare Copper Braid Shielded PVC Sumflex® RC4V-K 0.6/1kV Eca CPR Screen Cable: 100 Amps
Application:
The RC4V-K CPR cables comply with the criteria for the classification of construction products according to CPR Regulation 305/2011 and the EN 50575 standard, being those indicated in installations where electromagnetic protection is required to avoid parasitic currents. Its use is recommended in applications for control and command of variators, solenoid valves, starting machines and automata, regulation of current or voltage temperature in motorized valves.
Suitable for the following installations:
- ITC-BT 07 Underground networks for low voltage distribution
- ITC-BT 09 Underground power networks for outdoor lighting installations
- ITC-BT 11 Electrical power distribution networks. underground connections
- ITC-BT 20 Interior or reception installations
- ITC-BT 30 Installations in premises with special characteristics
Also Known as:
Sumflex® RC4V-K Cable, Sumcab, Screen Cable, RC4V-K Cable, Sumflex Cable, Braid Cable
Design:
• Flexible electrolytic copper conductor (Class 5) according to UNE-EN 60228, EN 60228 and IEC 60228 Insulation
• Cross-linked polyethylene (XLPE) type DIX 3 according to UNE 21123, HD 603 S1 and IEC 60502-1 Conductor
• identification according to UNE 21089 and HD 308 S2
• Copper wire braid, with 60% coverage on a polyester envelope that covers the wiring assembly according to UNE 21123 Polyvinyl chloride type DMV-18 according to UNE 21123, UNE-HD 603-1 and IEC 60502
• black color
Technical Data:
Rated voltage 0.6/1 kV Test
voltage 3,500 V AC
Maximum temperature 90 °C (250 °C for 5 seconds in the event of a short circuit)
Minimum bending radius 8 x External diameter in fixed installation Service
temperature -25 °C to +90 °C
Specification:
AWG Size: 14
Number of Conductor: 2
Conductor: Bare Copper
Conductor x Section: 2 x 2.50 mm²
Resistance at 20 °C: 7.98 ohm/km
Outer diameter approx: 10.3 mm
Rated Voltage: 0.6/1 kV
Weight: 104.15 lbs/MFT
*Data provided on this page is subject to change based on different manufacturers' variances
** Images are for display purposes only refer to Product Technical Details for accurate information on the product.
In the case the material only comes in a predetermined color or doesn’t come with any color
Reviews
Call Us: 1-516-482-6313 Text Us: 1-516-703-3460