12 AWG 3C NPC Shield TC Braid Polyolefin Freeze Protection Hazardous S
nassaunationalcable.com/en-ca/products/12-awg-3c-npc-shield-tc-braid-polyolefin-freeze-protection-hazardous-sc-f-series-heating-cable

Items in Cart ()

View cart

12 AWG 3C NPC Shield TC Braid Polyolefin Freeze Protection Hazardous SC/F Series Heating Cable

12 AWG 3C NPC Shield TC Braid Polyolefin Freeze Protection Hazardous SC/F Series Heating Cable
Roll over image to Zoom

12 AWG 3C NPC Shield TC Braid Polyolefin Freeze Protection Hazardous SC/F Series Heating Cable

SKU: P000000424
sc-f-series-npc-shield-tc-braid-polyolefin-freeze-protection-hazardous-heating-cable
Min Length: 1 FT
Max Length: 10000 FT
Price:
Regular price
$0.00 /FT
Sale price
$0.00 /FT
Shipping Cost Calculated at Checkout. Standard Lead Time is 1 to 6 Business Days.
Free Shipping: On orders above $1000
Quantity must be 1 or more

Enter the required footage in the quantity box - Cut to one length

Customer Reviews

Be the first to write a review
0%
(0)
0%
(0)
0%
(0)
0%
(0)
0%
(0)

Where are we? 4 Continents 8 Countries

map
garrie

Got any Questions?

Speak with a real person who will go out of their way to help you!

Call Us: 1-516-482-6313Text Us: 1-516-703-3460

Chat

Live Chat: Bottom Right Corner!

Email Us

info@nassaunationalcable.com

Product Information

Specification

12 AWG 3C NPC Shield TC Braid Polyolefin Freeze Protection Hazardous SC/F Series Heating Cable

Allowable Ampacity for 12 AWG 3C NPC Shield TC Braid Polyolefin Freeze Protection Hazardous SC/F Series Heating Cable: 100 Amps

About:

This heating cable, characterized by an 12 AWG gauge and three conductors (3C), incorporates a Nickel-Plated Copper (NPC) shield and a Tinned Copper (TC) braid, encapsulated in a polyolefin insulation. Its construction is aimed at providing reliable freeze protection while ensuring safety in hazardous locations, denoted by the SC/F series classification.

Also Known As:

 Triple-conductor hazardous area freeze protection cable
12 AWG 3C NPC shielded, TC braided polyolefin heating cable
 SC/F series polyolefin-insulated heating system for hazardous environments
 Three-core NPC shielded heating cable for explosive atmospheres

Application:

 Maintaining fluid flow by preventing freeze-up in pipes, valves, and tanks within oil and gas facilities, especially in areas with explosive risks.
 Ensuring the operational integrity of process lines and fire protection systems in chemical plants or facilities handling volatile substances.
 Providing necessary temperature maintenance for safety systems and instrumentation in environments classified as hazardous, such as pharmaceutical manufacturing.

Standards:

• ATEX and IECEx certifications for safe use in explosive atmospheres, ensuring global compliance.
• NEC guidelines for hazardous locations, validating its use within North American safety regulations.
• Likely certifications from safety organizations like UL or CSA, demonstrating its adherence to high safety and performance standards.
• Conformity with relevant industry-specific standards, guaranteeing reliability and safety in its designated applications.

Construction:

• Conductive Core: Three 12 AWG conductors, nickel-plated to enhance electrical conductivity and resistance to corrosion.
• Insulation: High-quality polyolefin insulation provides excellent chemical resistance and electrical isolation.
• Shielding: A TC braid surrounds the insulated conductors, offering added mechanical protection, grounding, and EMI/RFI interference resistance.
• Outer Jacket: A polyolefin outer layer further protects against environmental hazards, chemical exposure, and mechanical wear.

Features:

 Fast installation, with long circuit length capability: up to 12,000 ft/3659 m from a single power source
 Safe and efficient in operation, supports high voltages up to 600 VAC
 Reliable during long life: 10 year extended product warranty available, maintenance free

Specifications:

• Bus wire size: 12 AWG
• Conductor Quantity: 3
• Item Name: 3SC/F60-CR
• Outer Jacket Material: Polyolefin
• Area Classification: Non-Hazardous; Hazardous
• Color: Red
• Supply Voltage: 0 – 600 V
• Nominal Resistance @ 68°F: 0.001868 Ω/ft
• Nominal Width: 0.53 in
• Nominal Height: 0.25 in
• Min Bending Radius: 1 in
• Max Power Output: 6 W/ft
• Max Continuous Exposure Temperature, Power Off: 195 °F
• Max Intermittent Exposure Temperature, Power Off: 195 °F
• Min Installation Temperature: -40 °F
• Weight: 0.21 lb/ft
• Part Number: P000000424


*Data provided on this page is subject to change based on different manufacturers' variances
** Images are for display purposes only refer to Product Technical Details for accurate information on the product.
In the case the material only comes in a predetermined color or doesn’t come with any color