12 AWG 11C Shielded VNTC TC-ER Control Cable PVC Jacket 600V
Where are we? 4 Continents 8 Countries
Got any Questions?
Speak with a real person who will go out of their way to help you!
Call Us: 1-516-482-6313Text Us: 1-516-703-3460
Chat
Live Chat: Bottom Right Corner!
Email Us
info@nassaunationalcable.com
Quick Support
Product Information
Specification
12 AWG 11C Shielded VNTC TC-ER Control Cable PVC Jacket 600V
Applications:
UL listed and OSHA acceptable. Recognized for use in Class 1 or 2, Division 2 hazardous locations and for installation in trays, wireways, troughs, channels, ducts and conduit. Specifically approved for direct burial, wet or dry locations and outdoors in cable trays where a sunlight resistant rating is required. Designed for control, power, lighting, telemetering, signals and relay or traffic control where shielding against external interference is required.
Also Known As:
12 AWG 11C Shielded Tray Cable, 12 AWG 11C600V Shielded Control Cable, 12 AWG 11C VNTC 11C Tray Cable, 12 AWG 11C VNTC TC-ER, 12 AWG 11C VNTC Control Cable, 12/11C PVC Jacket 600V.
Features:
This specification covers multiconductor shielded cables having VW-1 TFFN or THHN/THWN (PVC/Nylon) conductors, an aluminum polyester tape shield with drain wire, and an overall gas/vapor-tight polyvinyl chloride (PVC) jacket; conforming to Article 318 "Cable Trays" and Article 340 "Power and Control Cable Type TC" of the 1999 National Electrical Code, and Standard 1277 of Underwriters Laboratories, Inc. They meet the requirements of the ICEA T-29-520 and T-30-520 flame tests as well as the 70,000 BTU "Cable Tray Propagation Test" per IEEE-383 and show reserve capabilities by also passing the 210,000 BTU flame test. Rated 600 volts, 90°C dry and 75°C wet. They also meet the CSA FT4 and the IEEE 1202 70,000 BTU flame test.
CONSTRUCTION:
Conductors:
Bare, soft annealed copper per ASTM B-3
Sizes 18 and 16 AWG (TFFN)
Bunch stranded, Size 18 (16/.010") and Size 16 (19/.0117") UL-62 paragraph 10.2
Sizes 14, 12 and 10 AWG (THHN/THWN)
Concentric stranded, class B (7 strands) per ASTM B-8 and UL-83 table 13.1
Insulation:
High dielectric polyvinyl chloride
UL-1581 table 50.145 (THWN 75°C)
UL-1581 table 50.155 (THHN 90°C)
UL-1581 table 50.155 Class 12B (TFFN 90°C)
Thickness: UL-83 table 15.5 for THHN/THWN and UL-62 table 6.2 for TFFN
Insulation Armor:
Nylon: UL-83 paragraph 25.1 for THHN/THWN & UL-62 paragraph 22.1 for TFFN
Thickness: UL-83 table 15.5 for THHN/THWN and UL-62 paragraph 26.4 for TFFN
Drain Wire:
Tinned copper per ASTM B-33
Sizes 20, 18 and 16 AWG
Concentric stranded, class B (7 strands), ASTM B-8
Shielding:
A .00035 aluminum foil/.001 polyester tape shield is applied helically with a 15% minimum overlap.
Overall Jacket:
Gas/vapor-tight Polyvinyl Chloride (black) - UL 1277 table 10.1
Thickness - Specified herein
Specifications:
• AWG: 12
• No. of Conductors: 11
• Overall Jacket Thickness Mils: 60
• Approx. Outside Diameter (In): .708
• Approx. Weight 1000 FT (Pounds): 377
*Data provided on this page is subject to change based on different manufacturers' variances
** Images are for display purposes only refer to Product Technical Details for accurate information on the product.
In the case the material only comes in a predetermined color or doesn’t come with any color
Download PDF Spec Sheet
Reviews
Call Us: 1-516-482-6313 Text Us: 1-516-703-3460