114-23-3060 350 MCM 1C Stranded Uncoated Copper Shield Okoguard Okocle
nassaunationalcable.com/en-ca/products/114-23-3060-350-mcm-1c-stranded-uncoated-copper-shield-okoguard-okoclear-tp-mv-105-5-8kv-power-cable
Items in Cart ()
View cart

114-23-3060 350 MCM 1C Stranded Uncoated Copper Shield Okoguard Okoclear-TP MV-105 5/8KV Power Cable

114-23-3060 350 MCM 1C Stranded Uncoated Copper Shield Okoguard Okoclear-TP MV-105 5/8KV Power Cable
Roll over image to Zoom
114-23-3060 350 MCM 1C Stranded Uncoated Copper Shield Okoguard Okoclear-TP MV-105 5/8KV Power Cable
SKU: 114-23-3060
okoguard-stranded-uncoated-copper-shield-okoclear-tp-mv-105-5-8kv-power-cable
Min Length: 1 FT
Max Length: 10000 FT
Price:
Regular price
$0.00 /FT
Sale price
$0.00 /FT
Shipping Cost Calculated at Checkout. Standard Lead Time is 1 to 6 Business Days.
Free Shipping: On orders above $1000
Quantity must be 1 or more

Enter the required footage in the quantity box - Cut to one length

Customer Reviews

Be the first to write a review
0%
(0)
0%
(0)
0%
(0)
0%
(0)
0%
(0)

Where are we? 4 Continents 9 Countries

map
garrie

Got any Questions?

Speak with a real person who will go out of their way to help you!

Call Us: 1-516-482-6313Text Us: 1-516-703-3460

Product Information
Specification

114-23-3060 350 MCM 1C Stranded Uncoated Copper Shield Okoguard Okoclear-TP MV-105 5/8KV Power Cable

Allowable Ampacity for 114-23-3060 350 MCM 1C Stranded Uncoated Copper Shield Okoguard Okoclear-TP MV-105 5/8KV Power Cable:100 Amps

About:

This specific cable model, designated as 114-23-3060, features a 350 MCM stranded uncoated copper conductor, ensuring efficient power transmission and flexibility for installation. It is insulated with Okoguard, Okonite's proprietary ethylene-propylene rubber (EPR) compound, and protected by a copper shield and an Okoclear-TP outer jacket. The MV-105 classification indicates its suitability for medium voltage applications up to 5/8 kilovolts, designed to provide reliable and safe power.

Also Known As:

• 350 MCM MV-105 Okoguard Cable
• Medium Voltage Copper Power Cable
• 5/8kV Stranded Copper Okoclear Cable

Applications:

• Okoguard Shielded Okoclear-tp Type Mv-105 Power Cables Are Recommended For Use As Feeder Circuits, In Electric Utility Generating Stations, For Distribution Circuits, And For Feeders Or Branch Circuits In Industrial And Commercial Installations, Where A Cable With Low Smoke/zero Halogen Characteristics Is Needed.
• Type Mv Cables May Be Installed In Wet Or Dry Locations, Indoors Or Outdoors (Exposed
To Sunlight), In Any Raceway Or Underground Duct, Directly Buried If Installed In A System With A Grounding Conductor In Close Proximity That Conforms With Nec Section 250.4(A)(5), And 315.36 Or Messenger Supported In Industrial Establishments And Electric Utilities.
• May Be Installed In Cable Trays Where Permitted By Nec Section 315.32(3).

Standards:

• IEEE 1202 or UL 1685 (Vertical Tray Flame Tests) for fire resistance
• ICEA S-93-639/NEMA WC 74 for medium voltage power cables
• UL 1072 for medium voltage power cables

Construction:

• Conductor: Uncoated copper compact stranded per ASTM B-496.
• Strand Screen: 
Extruded semiconducting EPR strand screen. Meets or exceeds electrical and physical requirements of ICEA S-93-639/NEMA WC74 & S-97-682, AEIC CS8, and UL 1072.
• Insulation: 
Meets or exceeds electrical and physical requirements of ICEA S-93-639/NEMA WC74 & S-97-682, AEIC CS8, and UL 1072.
• Insulation Screen:
 Extruded semiconduction EPR insulation screen. Meets or exceeds electrical and physical requirements of ICEA S-93-639/NEMA WC74 & S-97-682, AEIC CS8, and UL 1072.
• Shield: 
5 mil bare copper tape helically applied, with 25% minimum overlap.
• Jacket:
 Meets or exceeds electrical and physical requirements of ICEA S-93-639
for Type I thermoplastic polyolefin jackets. UL listed as Type MV-105, sunlight resistant and for use in cable tray in
accordance with UL 1072.

Features:

• Low smoke/zero halogen jacket.
• Low smoke/zero halogen jacket.
• Okoguard cables meet or exceed all recognized industry standards (UL, NEMA/ICEA and IEEE).
• Triple tandem extruded, all EPR system.
• 105°C continuous operating temperature.
• 140°C emergency rating.
• 250°C short circuit rating
• Excellent corona resistance.
• Exceptional resistance to “treeing”.
• Screens are clean stripping.
• Exceptional resistance to moisture.
• Resistant to most oils, acids, and alkalis.
• UL listed: MV-105, Sunlight Resistant, and Cable Tray Use.
• Passes the UL & IEEE 383-1974 Vertical Tray Flame Test.
• Sizes 500 kcmil and larger pass FT4/IEEE 1202 Vertical Tray Flame Test.

Specifications:

• Conductor Size AWG: 350 MCM
• Conduit Size Inches (5):
3 1/2

• Approx. Dia. over Insulation (in.): 0.89
• Jacket Thickness (mm): 2.03

• Approx. O.D. (Inches): 1.21
• Approx. Net Weight: 1575
• Ampacities (2) Conduit in Air: 440
• Ampacities (3) Underground Duct:
415
• Ampacities (4) Cable Tray:
610
• Part Number: 114-23-3060


*Data provided on this page is subject to change based on different manufacturers' variances
** Images are for display purposes only refer to Product Technical Details for accurate information on the product.
In the case the material only comes in a predetermined color or doesn’t come with any color
Download PDF Spec Sheet

Reviews

Customer Reviews

Be the first to write a review
0%
(0)
0%
(0)
0%
(0)
0%
(0)
0%
(0)
Get in Touch
Live Chat Get replies right away!
Email info@nassaunationalcable.com

Call Us: 1-516-482-6313    Text Us: 1-516-703-3460