112-36-3201 300 MCM 1C 37Strand Bare Copper Unshielded X-Olene FMR RHW-2 Okonite Power And Control Cable
Where are we? 4 Continents 8 Countries
Got any Questions?
Speak with a real person who will go out of their way to help you!
Call Us: 1-516-482-6313Text Us: 1-516-703-3460
Chat
Live Chat: Bottom Right Corner!
Email Us
info@nassaunationalcable.com
Quick Support
Product Information
Specification
112-36-3201 300 MCM 1C 37Strand Bare Copper Unshielded X-Olene FMR RHW-2 Okonite Power And Control Cable
Allowable Ampacity for 112-36-3201 300 MCM 1C 37Strand Bare Copper Unshielded X-Olene FMR RHW-2 Okonite Power And Control Cable:100 Amps
About:
This cable features a 300 MCM bare copper conductor, 37Strand which provides excellent electrical conductivity and mechanical durability. The insulation is made of X-Olene, a proprietary type of cross-linked polyethylene known for its high resistance to heat, flame, and chemical exposure. Being unshielded, it is more suitable for environments where electromagnetic interference is not a primary concern. The "FMR" designation indicates the cable's flame-retardant properties, and "RHW-2" signifies its suitability for both wet and dry conditions at temperatures up to 90°C.
Also Known As:
• Okonite 300 MCM 37Strand Bare Copper Power Cable
• X-Olene Insulated Unshielded Cable
• FMR RHW-2 Power and Control Cable
Application:
• X-Olene-FMR Type RHH or RHW-2 600/1000 Volt Power and Control Cables are
recommended for general low voltage power and control applications.
• Where the National Electrical Code applies, Type RHH or RHW-2 may be used up to 90°C in dry or wet locations.
• These cables may be installed in wet or dry locations, indoors or outdoors, in raceways, underground ducts, directly buried in the earth, or lashed to a messenger for aerial installation.
• Sizes 8 AWG & larger may be used for 600V underground distribution per ANSI/ICEA S 105-69
Standards:
• RHW-2 Indicates suitability for use in wet or dry locations at temperatures up to 90°C when exposed to oil or coolants.
• Meets flame test requirements as specified by relevant industry standards.
• Typically conforms to ASTM standards for bare copper conductors.
• UL listed, ensuring compliance with safety and quality standards.
Construction:
• Conductor: Uncoated soft copper per ASTM B-3. Solid per ASTM B-3. Sizes smaller than #8 are compress stranded per ASTM B-8. Sizes #8 and larger are compact stranded per ASTM B-496.
• Insulation: Meets or exceeds all requirements of ICEA S-95-658, NEMA WC-70, and UL Standards 44 and 854. Listed by Underwriters Laboratories, Inc. as Type RHH or RHW-2. Meets the requirements of ANSI/ICEA S-105-692
Features:
• Outstanding heat resistance.
• Rated 90°C wet or dry.
• Mechanically rugged.
• Stable electrical properties.
• Low moisture absorption.
• Highly resistant to weather and most chemicals.
• UL Listed.
• Meets ANSI/ICEA S-105-692.
• Oil resistant, PR I & PR II.
• Gasoline and oil resistant, GR I & GR II.
• Sunlight resistant.
• CSA RW90 listing on special request.
• VW-1.
• Sizes 1/0 or larger listed for CT-USE.
• -40°C.
• FT4.
Specifications:
• Conductor Size AWG/kcmil: 300
• Number of Strands: 37
• Insulation Thickness (mils): 95
• Insulation Thickness (mm): 2.41
• Approx. O.D (Inches): 0.78
• Approx. O.D (mm): 19.81
• 90°C Wet (1)* NEC Ampacity: 320
• 75°C Wet (1)* NEC Ampacity: 285
• ICEA Ampacity (2): 351
• Approx. Net Weight (Lbs): 1025
• Part Number: 112-36-3201
*Data provided on this page is subject to change based on different manufacturers' variances
** Images are for display purposes only refer to Product Technical Details for accurate information on the product.
In the case the material only comes in a predetermined color or doesn’t come with any color
Download PDF Spec Sheet
Reviews
Call Us: 1-516-482-6313 Text Us: 1-516-703-3460