1000 MCM HVTECK Copper 140 mil TRXLPE TS AIA 8kV 133% IL Orange PVC Jacket CSA Cable
Where are we? 4 Continents 9 Countries

Got any Questions?
Speak with a real person who will go out of their way to help you!
Call Us: 1-516-482-6313Text Us: 1-516-703-3460
Quick Support
1000 MCM HVTECK Copper 140 mil TRXLPE TS AIA 8kV 133% IL Orange PVC Jacket CSA Cable
Applications:
The 8kV HVTECK is a CSA armoured cable for industrial and commercial medium voltage applications. Rated FT4, -40°C, Hazardous Locations (HL). These cables are capable of operating continuously at the conductor temperature not in excess of 105°C for normal operation, 140°C for emergency overload, and 250°C for short circuit conditions. Rated for 1000 lbs /FT maximum sidewall pressure. These cables feature sunlight and moisture resistance, exceptional corona resistance, resistance to most chemical soils and acids and are flame retardant. Single Conductor, 140 Mils Tree Retardant Cross Linked Polyethylene, 133% Insulation Level, Tape Shield, Polyvinyl Chloride (PVC) Inner Jacket, Aluminum Interlocked Armour (AIA), Polyvinyl Chloride (PVC) Jacket.
Also Known As:
1000 MCM HVTECK Cable, 1000 MCM 8kV HVTECK Cable, 1000 MCM 8kV Medium Voltage Cable, 1000 MCM MV Armored Cable, 1000 MCM Copper Medium Voltage Cable, 1000 MCM Single Conductor MV Cable, 1000 MCM 1/C Copper Cable, 1000 MCM 8kV Shielded Power Cable, 1000 MCM133% Insulation Level Cable, 1000 MCM 140 Mil TR-XLPE Cable, 1000 MCM Tree Retardant XLPE Cable, 1000 MCM Aluminum Interlocked Armor Cable, 1000 MCM AIA Armored Cable, 1000 MCM Copper Tape Shielded Cable, 1000 MCM PVC Jacketed MV Cable, 1000 MCM Orange Jacket Power Cable, 1000 MCM CSA Armored Cable, 1000 MCM 105°C Medium Voltage Cable, 1000 MCM Industrial Power Cable, 1000 MCM Hazardous Location Cable, 1000 MCM FT4 Flame Retardant Cable, 1000 MCM Sunlight Resistant Cable, 1000 MCM Southwire HVTECK Cable.
Constructions:
Conductor: Class B compressed stranded bare copper per ASTM B3 and ASTM B8
Conductor Shield: Semi-conducting cross-linked copolymer
Insulation: 140 Mils Tree Retardant Cross Linked Polyethylene 133% insulation level
Insulation Shield: Strippable semi-conducting cross-linked copolymer
Copper Tape Shield: Helically wrapped 5 mil copper tape with 25% overlap
Inner Jacket: PVC inner jacket
Armour: Aluminum Interlocked Armour (AIA)
Overall Jacket: Orange Polyvinyl Chloride (PVC) Jacket
Standards:
ASTM B3 Soft or Annealed Copper Wire
ASTM B8 Concentric-Lay-Stranded Copper Conductors
CSA C22.2 No. 174 Cables in Hazardous Locations
CSA C22.2 No. 2556 & No. 0.3 Wire and Cable Test Methods
CSA C68.10 Shielded Power Cables for Commercial and Industrial Applications - 5 to 46 KV
CSA C68.3 Shielded & Concentric Neutral Power Cable - 5 to 46 kV
CSA LTGG [-40°C] - as per C68.10 - for Cold Bend and Impact rating
CSA HL - for Hazardous Locations rating
CSA SUN RES - for Sunlight Resistant rating
ICEA S-93-639 (NEMA WC 74) 5-46 KV Shielded Power Cable
ICEA T-29-520 Flame Test (210,000 BTU/Hr)
IEEE 383 Flame Test (70,000 btu)
IEEE 1202 FT4 Flame Test (70,000) BTU/hr Vertical Tray Test (1/0 and Larger)
FT1 Flame Test (1,706 BTU/Hr nominal - Vertical Wire Flame Test)
AEIC CS-8 Specification for extruded dielectric shielded power cables rated for 5 through 46KV (Qualification Test Requirements).
Specification:
Strand: 61
Diameter Over Conductor: 1.117 inch
Diameter Over Insulation: 1.453 inch
Insulation Thickness: 140 mil
Diameter Over Insulation Shield: 1.513 inch
Inner Jacket Thickness: 110 mil
Dia. Over Armour: 2.109 inch
Overall Jacket Thickness: 60 mil
Approx.OD: 2.229 inch
Copper Weight(lb/1000ft): 3118
Approx. Weight(lb/1000ft): 4587
Call Us: 1-516-482-6313 Text Us: 1-516-703-3460