1000' 250 MCM 4C Unshielded Tray Cable W/ Ground XLPE Insulation PVC Jacket 600V E2
Where are we? 4 Continents 9 Countries

Got any Questions?
Speak with a real person who will go out of their way to help you!
Call Us: 1-516-482-6313Text Us: 1-516-703-3460
Quick Support
1000' 250 MCM 4C Unshielded Tray Cable W/ Ground XLPE Insulation PVC Jacket 600V E2
Applications:
Primarily used for power, control, signal, communication and lighting circuits in commercial and industrial environments. Suitable for installation in cable trays, supported by messenger in open air, raceways, channels, conduits and ducts. Approved for direct burial applications and outdoors in cable tray where sunlight resistant rating is required. Also may be installed in wet or dry locations or in areas exposed to chemicals and oils.
Also Known As:
250 MCM 4C Cable Tray, 250 MCM 4C Cable Tray Types, 250 MCM 4C Electrical Cable Tray, 250 MCM 4C Pvc Cable Tray, 250 MCM 4C wire cable tray, 250 MCM 4C cable tray wire, 250 MCM 4C Tray Instrument Cable, 250 AWG 4C Tray Instrumentation Cable, 250 MCM 4C TC-ER Cable, 250 MCM 4C direct burial tray cable, 250 MCM 4C EPR Cable, 250 MCM 4C CPE Cable, 250 AWG 16C Exposed Run Tray Cable, 14 AWG 16C XHHW tray cable,250 MCM 4C XHHW tray wire, 250 MCM 4C tinned copper tray cable, 250 MCM 4C Chlorinated Polyethylene cable, 250 MCM 4C Ethylene Propylene Rubber cable, 250 MCM 4C flame-retardant tray cable, 250 MCM 4C tray power cable, 250 MCM 4C tray control cable, 250 MCM 4C FREP cable.
Standards:
• UL Listed as TC-ER (Exposed Run) per UL Standard 1277 and used in accordance with NEC for 3 or more conductors.
• Approved for Class 1 or 2, Division 2 industrial hazardous locations per NEC
• Individual conductors pass UL VW-1 flame test and rated XHHW-2/VW1, UL 1581/UL 2556 VW-1
• Rated at 90°C wet or dry
• Oil Res I & II
• “Heavy Duty” rating per ICEA Standards
• Meets cold bend test at -25°C
• NEMA WC70/ICEA S-95-658, NEMA WC57/ICEA S-73-532
• IEEE 1202 and CSA FT4 70,000 BTU Flame Test
• IEEE 383 70,000 BTU Vertical Flame Test
• ICEA T-29-520 210,000 BTU
Conductor:
• Fully annealed bare copper per ASTM B-3, Class B stranding per ASTM B-8
Insulation:
• Flame retardant Cross-linked Polyethylene (FR-XLPE) that is heat and moisture resistant. Also has a VW-1 rating and is XHHW-2 per UL 44
Jacket:
• Flame and sunlight resistant black PVC rated 90°C wet or dry per UL 1277
Specification:
• Gauge: 250 MCM
• No. Conductors: 4
• No. of Strands: 37
• Insulation Thickness: 0.065 Inches
• Jacket Thickness: 0.080 Inches
• Overall Diameter : 1.88 Inches
• New Weight lb/1000FT: 5845 Lbs
|