3/0-3/0-1/0 Hollins Triplex Aluminum Conductor Underground Direct Burial 600V URD

Where are we? 4 Continents 8 Countries


Got any Questions?
Speak with a real person who will go out of their way to help you!
Call Us: 1-516-482-6313Text Us: 1-516-703-3460
Quick Support
3/0-3/0-1/0 Hollins Triplex Aluminum Conductor Underground Direct Burial 600V URD
Allowable Ampacity for 3/0-3/0-1/0 Hollins Triplex Aluminum Conductor 600V URD direct burial: 280 Amps
Allowable Ampacity for 3/0-3/0-1/0 Hollins Triplex Aluminum Conductor 600V URD in duct: 205 Amps
Applications:
The 3/0-3/0-1/0 Hollins Triplex Aluminum URD Cable is designed for single-phase secondary power distribution in underground electrical systems. It is 600V-rated and suitable for direct burial or installation in ducts. With aluminum conductors and XLPE insulation, this cable is moisture-resistant, heat-resistant, and durable for outdoor use.
With a maximum operating temperature of 90°C, it performs reliably in both wet and dry environments. The triplex configuration, consisting of two 3/0 AWG phase conductors and a 1/0 AWG neutral, makes it ideal for single-phase service drops from transformers to buildings.
Also Known As:
3/0-3/0-1/0 hollins aluminum urd cable, 3/0-3/0-1/0 hollins urd direct burial cable, 3/0-3/0-1/0 hollins three conductor cable, 3/0-3/0-1/0 hollins tri plex wire, 3/0-3/0-1/0 hollins triplex cable, 3/0-3/0-1/0 hollins triplex aluminum underground wire, 3/0-3/0-1/0 hollins 3 conductor power cable, 3/0-3/0-1/0 hollins aluminum triplex, 3/0-3/0-1/0 hollins underground triplex, 3/0-3/0-1/0 hollins triplex underground cable, 3/0-3/0-1/0 hollins triplex wire underground, 3/0-3/0-1/0 hollins direct burial triplex, 3/0-3/0-1/0 hollins triplex conductor, 3/0-3/0-1/0 hollins direct burial electrical cable, 3/0-3/0-1/0 hollins direct burial power cable, 3/0-3/0-1/0 hollins aluminum direct burial cable.
Standards:
-
ASTM B-230
-
ASTM B-231
-
ASTM B-609
-
ASTM B-901
-
ICEA S-105-692
-
J-C- 30B Federal Specification
-
RUS accepted
Construction
Conductors:
Aluminum conductors used for this cable are designed in either concentric strand or in compressed series. The advantage with a compressed conductor is the reduced bulkiness. Compressed conductors are also stronger and tougher; the stranded conductors are highly flexible and tend to have lower electrical resistance. Stranded conductors therefore reduce power loss and are also easier to use in applications where flexibility is vital. Aluminum 600 V URD cable has three aluminum conductors.
Insulation:
Versatile insulation system made of cross linked black polyethylene material helps to secure the cable conductors. This insulation is water tight, repulsive to corrosive substances, resistant to oil, heat and flame. Cross linking a polyethylene helps to achieve an excellent strength that makes the material suitable for covering this cable used in harsh conditions like direct burial installation.
Specifications:
-
Size AWG: 3/0
-
Neutral Conductor Size AWG: 1/0
-
Phase Conductor Insulation Thickness: 0.080 inches
-
Natural Conductor Insulation Thickness: 0.080 inches
-
O.D. Inches: 1.276
-
Weight lbs./1000ft: 608 lbs
-
Ampacity: Direct burial: 280 Amps
-
Ampacity: In duct: 205 Amps