2/0-2/0-1 Converse Triplex Aluminum Conductor Underground Direct Burial 600V URD
Where are we? 4 Continents 8 Countries
Got any Questions?
Speak with a real person who will go out of their way to help you!
Call Us: 1-516-482-6313Text Us: 1-516-703-3460
Chat
Live Chat: Bottom Right Corner!
Email Us
info@nassaunationalcable.com
Quick Support
Product Information
Specification
2/0-2/0-1 Converse Triplex Aluminum Conductor Underground Direct Burial 600V URD
Allowable Ampacity for 2/0-2/0-1 Converse Triplex Aluminum Conductor 600V URD direct burial: 245 Amps
Allowable Ampacity for 2/0-2/0-1 Converse Triplex Aluminum Conductor 600V URD in duct: 180 Amps
Applications:
The Aluminum 600V URD is designed to serve in the secondary distribution circuits for power. In these secondary circuits, the electrical cable is installed in duct or direct burial applications. Due to its versatility, conductor strength, and insulation integrity, it works well for these outdoor applications. It is also used in wet and dry places since the electrical cable has a maximum operating temperature of 90°C. The triplex wire for sale is also designed to provide an option of pre-pulling into ducts.
Also Known As:
2/0-2/0-1 converse aluminum urd cable, 2/0-2/0-1 converse aluminum urd direct burial cable, 2/0-2/0-1 converse aluminum three conductor cable, 2/0-2/0-1 converse aluminum tri plex wire, 2/0-2/0-1 converse aluminum triplex cable, 2/0-2/0-1 converse aluminum triplex aluminum underground wire, 2/0-2/0-1 converse aluminum 3 conductor power cable, 2/0-2/0-1 converse aluminum aluminum triplex, 2/0-2/0-1 converse aluminum underground triplex, 2/0-2/0-1 converse aluminum triplex underground cable, 2/0-2/0-1 converse aluminum triplex wire underground, 2/0-2/0-1 converse aluminum direct burial triplex, 2/0-2/0-1 converse aluminum triplex conductor, 2/0-2/0-1 converse aluminum direct burial electrical cable, 2/0-2/0-1 converse aluminum direct burial power cable, 2/0-2/0-1 converse aluminum aluminum direct burial cable.
Standards:
-
ASTM B-230
-
ASTM B-231
-
ASTM B-609
-
ASTM B-901
-
ICEA S-105-692
-
J-C- 30B Federal Specification
-
RUS accepted
Construction
Conductors:
Aluminum conductors used for this cable are designed in either concentric strand or in compressed series. The advantage with a compressed conductor is the reduced bulkiness. Compressed conductors are also stronger and tougher; the stranded conductors are highly flexible and tend to have lower electrical resistance. Stranded conductors therefore reduce power loss and are also easier to use in applications where flexibility is vital. Aluminum 600 V URD cable has three aluminum conductors.
Insulation:
Versatile insulation system made of cross linked black polyethylene material helps to secure the cable conductors. This insulation is water tight, repulsive to corrosive substances, resistant to oil, heat and flame. Cross linking a polyethylene helps to achieve an excellent strength that makes the material suitable for covering this cable used in harsh conditions like direct burial installation.
Specifications:
-
Size AWG: 2/0
-
Stranding: 19
-
Insulation Thickness (mils): 80
-
Neutral Size AWG: 1
-
Single Phase Conductor Inches: 0.566
-
O.D. Inches: 1.174
-
Weight lbs./1000ft: 502 lbs
-
Ampacity: Direct burial: 245 Amps
-
Ampacity: In duct: 180 Amps
*Data provided on this page is subject to change based on different manufacturers' variances
** Images are for display purposes only refer to Product Technical Details for accurate information on the product.
In the case the material only comes in a predetermined color or doesn’t come with any color
Download PDF Spec Sheet
Reviews
Call Us: 1-516-482-6313 Text Us: 1-516-703-3460