HELUKABEL TOPSERVE 650 VFD XLPE MOTOR POWER SUPPLY CABLE ORANGE

Select a Gauge
Where are we? 4 Continents 9 Countries


Got any Questions?
Speak with a real person who will go out of their way to help you!
Call Us: 1-516-482-6313Text Us: 1-516-703-3460
Quick Support
HELUKABEL TOPSERVE 650 VFD XLPE MOTOR POWER SUPPLY CABLE ORANGE
Applications:
Highly flexible, extremely oil-resistant, thermoset-insulated motor supply cable for modern servomotors; the double-shielding with special aluminum foil (100% coverage) and tinned copper braid (approx. 85% coverage) provides effective protection against electrical disturbances and the resultant failures. XLPE insulation makes this compliant with the requirements outlined in the current edition of NFPA 79 Chapter 4. The special TPE jacket is extremely resistant to oil, coolants and solvents making it the perfect solution for industrial applications. Open, unprotected installation in cable trays and from cable trays to the machine, as well as in pipes and direct burial are approved. EMC = Electromagnetic compatibility To optimize the EMC features we recommend a large round contact of the copper braiding on both ends. (€= The product conforms to EC Low-Voltage Directive 2006/95/EC.
Also Known As:
HELUKABEL TOPSERV 650 VFD Orange Cable, XLPE Insulated VFD Cable, Oil-Resistant Motor Power Cable, Flexible VFD Power Supply Cable, EMC Shielded Motor Cable, UL TC-ER Rated Cable, NFPA 79 Compliant Cable, Direct Burial VFD Cable, Tinned Copper Braid Shielded Cable, Drag Chain Rated Power Cable.
Technical Data:
• XLPE-insulated motor supply cable acc. to UL Std. 1277 and 2277
Temperature range
UL/CSA TC -40°C to +90°C
flexing +5°C to +50°C
static -40°C to +105°C
Nominal voltage
UL/CSA TC 600 V
UL WTTC/Flexible Motor Supply 1000 V
Test voltage
power supply conductors 4000 V
control conductors 2000 V
Minimum bending radius
flexing 10x cable Ø
permanently flexing 7,5x cable Ø
Coupling resistance
max. 250 Ohm/km
Cable Structure:
• Finely stranded (Cl. M 18-10AWG; Cl. K 8-2 AWG), tinned copper acc. to AWG standards
• Special XLPE conductor insulation
• Black supply conductors with continuous white numbering
• 1 or 2 black control conductors with numbers 5+6 (1 pair), 7+8 (2 pair)
• GN-YE conductor in the outer layer
• Control conductors wrapped in non-woven separator and braided, tinned copper shield, approx. 85% coverage
• Control conductors stranded in pairs and laid up in layers with the power supply conductors in optimal lay lengths
• Overall non-woven separator
• Braided, tinned copper shield, approx. 85% coverage
• Separator
• Special TPE outer jacket
• Orange (RAL 2003) jacket
• With length marking in feet
Properties:
• Self-extinguishing and flame retardant acc. to CSA FT4
• The materials used during manufacturing are cadmium-free, contain no silicone and are free from substances harmful to the wetting properties of lacquers
• UV-resistant
• Direct burial rated
• Resistant to cleaning and disinfecting agents acc. to ECOLAB
Test:
• UL:
TC-ER (1277), WTTC (2277), ITC-ER &
PLTC-ER (18-12 AWG), 44 (14-2 AWG),
NFPA 79 Ch. 4, Class I Div. 2 per
NEC Art. 501, NEC Art. 336 & 392,
Oil Res I/II, 90°C Dry/Wet, -40°C Cold Bend
• CSA:
C22.2 No. 230 & 239 - c(UL) CIC-TC FT4
C22.2 No. 210 - AWM I/II A/B FT4
Note:
• VFD = Variable Frequency Drive
Available on request
• Black (RAL 9005) jacket
Call Us: 1-516-482-6313 Text Us: 1-516-703-3460