Applications:
Highly flexible, extremely oil-resistant, thermoset-insulated motor supply cable for modern servomotors; the double-shielding with special aluminum foil (100% coverage) and tinned copper braid (approx. 85% coverage) provides effective protection against electrical disturbances and the resultant failures. XLPE insulation makes this compliant with the requirements outlined in the current edition of NFPA 79 Chapter 4. The special TPE jacket is extremely resistant to oil, coolants and solvents making it the perfect solution for industrial applications. Open, unprotected installation in cable trays and from cable trays to the machine, as well as in pipes and direct burial are approved. EMC = Electromagnetic compatibility To optimize the EMC features we recommend a large round contact of the copper braiding on both ends. (€= The product conforms to EC Low-Voltage Directive 2006/95/EC.
Also Known As:
HELUKABEL TOPSERVE 600 specs, TOPSERVE VFD cable datasheet, HELUKABEL VFD cable XLPE, HELUKABEL motor cable 600V, TOPSERVE 600 VFD cable features, HELUKABEL 600V XLPE cable, VFD motor supply cable HELUKABEL, TOPSERVE XLPE cable applications, HELUKABEL VFD EMI shielding, TOPSERVE 600 cable.
Technical Data:
XLPE-insulated motor supply cable acc. to UL Std. 1277 and 2277
Temperature range
UL/CSA TC -40°C to +90°C
flexing +5°C to +50°C
static -40°C to +105°C
Nominal voltage
UL/CSA TC 600 V
UL WTTC/Flexible Motor Supply 1000 V
Test voltage
4000 V
Minimum bending radius
flexing 10x cable Ø
permanently flexing 7,5x cable Ø
Coupling resistance
max. 250 Ohm/km
Cable Structure:
• Finely standard (Cl. M 18-10AWG; Cl. K 8-2 AWG), tinned copper acc. to AWG standards
• Special XLPE conductor insulation
• Black conductors with continuous white numbering
• GN-YE conductor in the outer layer
• Conductors stranded in layers with optimal lay length
• Overall non-woven separator Braided, tinned copper shield, approx. 85% coverage
• Separator
• Special TPE outer jacket
• Orange (RAL 2003) jacket
• With length marking in feet
Properties:
• Self-extinguishing and flame retardant acc. to CSA FT4
• The materials used during manufacturing are cadmium-free, contain no silicone and are free from substances harmful to the wetting properties of lacquers
• UV-resistant
• Direct burial rated
• Resistant to cleaning and disinfecting agents acc. to
Test:
UL:
TC-ER (1277), WTTC (2277), ITC-ER &
PLTC-ER (18-12 AWG), 44 (14-2 AWG),
NFPA 79 Ch. 4, Class I Div. 2 per
NEC Art. 501, NEC Art. 336 & 392,
Oil Res I/II, 90°C Dry/Wet, -40°C Cold Bend
CSA:
C22.2 No. 230 & 239 - c(UL) CIC-TC FT4
C22.2 No. 210 - AWM I/II A/B FT4
Note:
VFD = Variable Frequency Drive
Available on request
Black (RAL 9005) jacket