{"product_id":"nema-a200-thermal-overload-relay-3-pole-starter-mounted-class-20-type-b-26-3-45a-1nc-auxiliary-contact","title":"NEMA A200 Thermal Overload Relay, 3-Pole, Starter-Mounted, Class 20, Type B, 26.3–45A, 1NC Auxiliary Contact","description":"\u003ctable width=\"100%\" style=\"width: 36.3478%; height: 293.906px;\"\u003e\n\u003ctbody\u003e\n\u003ctr style=\"height: 78.375px;\"\u003e\n\u003ctd style=\"width: 48.2796%; text-align: center; height: 78.375px;\"\u003e\u003cstrong\u003eModification\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 50.7428%; text-align: center; height: 78.375px;\"\u003e1NC Auxiliary Contact, Ambient Compensated\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 48.2796%; text-align: center; height: 19.5938px;\"\u003e\u003cstrong\u003eDesign\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 50.7428%; text-align: center; height: 19.5938px;\"\u003eNEMA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 39.1875px;\"\u003e\n\u003ctd style=\"width: 48.2796%; text-align: center; height: 39.1875px;\"\u003e\u003cstrong\u003eFull load current range\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 50.7428%; text-align: center; height: 39.1875px;\"\u003e26.3-45A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 48.2796%; text-align: center; height: 19.5938px;\"\u003e\u003cstrong\u003eMounting\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 50.7428%; text-align: center; height: 19.5938px;\"\u003eStarter\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 39.1875px;\"\u003e\n\u003ctd style=\"width: 48.2796%; text-align: center; height: 39.1875px;\"\u003e\u003cstrong\u003eNumber of poles\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 50.7428%; text-align: center; height: 39.1875px;\"\u003eThree-pole\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 39.1875px;\"\u003e\n\u003ctd style=\"width: 48.2796%; text-align: center; height: 39.1875px;\"\u003e\u003cstrong\u003eSpecial features\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 50.7428%; text-align: center; height: 39.1875px;\"\u003eHeaters required\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 39.1875px;\"\u003e\n\u003ctd style=\"width: 48.2796%; text-align: center; height: 39.1875px;\"\u003e\u003cstrong\u003eTrip Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 50.7428%; text-align: center; height: 39.1875px;\"\u003eThermal Type B, Class 20\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 48.2796%; text-align: center; height: 19.5938px;\"\u003e\u003cstrong\u003eType\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 50.7428%; text-align: center; height: 19.5938px;\"\u003eA200\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 48.2796%; text-align: center;\"\u003e\u003cstrong\u003eProduct Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 50.7428%; text-align: center;\"\u003eOverload relay\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 48.2796%; text-align: center;\"\u003e\u003cstrong\u003eProduct Length\/Depth\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 50.7428%; text-align: center;\"\u003e3.6 in\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 48.2796%; text-align: center;\"\u003e\u003cstrong\u003eProduct Height\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 50.7428%; text-align: center;\"\u003e4.8 in\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 48.2796%; text-align: center;\"\u003e\u003cstrong\u003eProduct Width\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 50.7428%; text-align: center;\"\u003e3.4 in\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003cp data-start=\"24\" data-end=\"384\" class=\"PDq2pG_selectionAnchorContainer\"\u003eThe \u003cstrong data-start=\"28\" data-end=\"71\"\u003eNEMA A200 3-Pole Thermal Overload Relay\u003c\/strong\u003e is designed to provide reliable motor overload protection for industrial motor control applications. This \u003cstrong data-start=\"178\" data-end=\"211\"\u003estarter-mounted thermal relay\u003c\/strong\u003e uses a \u003cstrong data-start=\"219\" data-end=\"256\"\u003eType B thermal overload mechanism\u003c\/strong\u003e with \u003cstrong data-start=\"262\" data-end=\"285\"\u003eClass 20 protection\u003c\/strong\u003e to help safeguard motors from excessive current conditions and prevent damage caused by overloads.\u003cspan aria-hidden=\"true\" class=\"PDq2pG_selectionAnchor\"\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp data-start=\"386\" data-end=\"713\"\u003eFeaturing an \u003cstrong data-start=\"399\" data-end=\"429\"\u003eambient-compensated design\u003c\/strong\u003e, this overload relay maintains accurate protection across varying operating temperatures. It includes a \u003cstrong data-start=\"534\" data-end=\"559\"\u003e1NC auxiliary contact\u003c\/strong\u003e for control circuit integration and supports a \u003cstrong data-start=\"607\" data-end=\"643\"\u003e26.3–45A full-load current range\u003c\/strong\u003e, making it suitable for a wide variety of motor starter applications.\u003c\/p\u003e\n\u003ch4 data-start=\"386\" data-end=\"713\"\u003eFeatures :\u003c\/h4\u003e\n\u003cp data-start=\"386\" data-end=\"713\"\u003e• NEMA A200 series thermal overload relay\u003c\/p\u003e\n\u003cp data-start=\"386\" data-end=\"713\"\u003e• 3-pole starter-mounted design\u003c\/p\u003e\n\u003cp data-start=\"386\" data-end=\"713\"\u003e• 26.3–45A adjustable overload range\u003c\/p\u003e\n\u003cp data-start=\"386\" data-end=\"713\"\u003e• Class 20 thermal protection\u003c\/p\u003e\n\u003cp data-start=\"386\" data-end=\"713\"\u003e• Type B thermal overload element\u003c\/p\u003e\n\u003cp data-start=\"386\" data-end=\"713\"\u003e• Ambient compensated for reliable performance in changing temperatures\u003c\/p\u003e\n\u003cp data-start=\"386\" data-end=\"713\"\u003e• Includes 1NC auxiliary contact\u003c\/p\u003e\n\u003cp data-start=\"386\" data-end=\"713\"\u003e• Designed for use with NEMA motor starters\u003c\/p\u003e\n\u003cp data-start=\"386\" data-end=\"713\"\u003e• Provides dependable motor protection in industrial and commercial applications\u003c\/p\u003e","brand":"Eaton","offers":[{"title":"Default Title","offer_id":64280938479985,"sku":"BA23A","price":229.99,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/5_33c14d2b-3086-4f2d-aad7-41d2b4b75d0b.png?v=1785132367","url":"https:\/\/nassaunationalcable.com\/products\/nema-a200-thermal-overload-relay-3-pole-starter-mounted-class-20-type-b-26-3-45a-1nc-auxiliary-contact","provider":"NassauNationalCable","version":"1.0","type":"link"}