{"product_id":"mv105-or-mv90-non-shielded-xlp-133-insulation-copper-cable-2-4kv","title":"MV105 OR MV90 Non-Shielded XLP 133% Insulation Copper Cable 2.4KV","description":"\u003cp\u003e[short] \u003cbr\u003e\u003c\/p\u003e\n\u003ch2\u003eMV105 OR MV90 Non-Shielded XLP 133% Insulation Copper Cable 2.4KV\u003c\/h2\u003e\n\u003ch3\u003e\u003cspan style=\"font-weight: 400;\"\u003eApplications:\u003c\/span\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cspan style=\"font-weight: 400;\"\u003eThe mv105 or mv90 copper cable is an electrical wire used for power circuits up to 5,000 Volts when fixed in open air, conduit, or duct; in applications such as chemical plants, refineries, steel mills, industrial plants, commercial buildings, utility substations, and generating stations. The National Electric Code accepts this electrical cable for uses within 90°C for continuous operation, 130°C for emergency overload conditions, and 250°C for short circuit conditions.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cspan style=\"font-weight: 400;\"\u003eAlso Known As:\u003c\/span\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cspan style=\"font-weight: 400;\"\u003eMedium voltage power cables, mv power cable, mv105 cable, mv90, mv105.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cspan style=\"font-weight: 400;\"\u003eStandards:\u003c\/span\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli style=\"font-weight: 400;\"\u003e\n\u003cp\u003e\u003cspan style=\"font-weight: 400;\"\u003eICEA S-96-659\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli style=\"font-weight: 400;\"\u003e\n\u003cp\u003e\u003cspan style=\"font-weight: 400;\"\u003eUL Standard 1072\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli style=\"font-weight: 400;\"\u003e\n\u003cp\u003e\u003cspan style=\"font-weight: 400;\"\u003eNEMA WC 71\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cspan style=\"font-weight: 400;\"\u003eConstruction\u003c\/span\u003e\u003c\/h3\u003e\n\u003ch4\u003e\u003cspan style=\"font-weight: 400;\"\u003eConductors:\u003c\/span\u003e\u003c\/h4\u003e\n\u003cp\u003e\u003cspan style=\"font-weight: 400;\"\u003eThe conductor is soft bare annealed copper per ASTM B-3, Class B stranding per ASTM B-8 (compressed), or ASTM B-496 (compact), with a semi-conducting conductor shield.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch4\u003e\u003cspan style=\"font-weight: 400;\"\u003eInsulation:\u003c\/span\u003e\u003c\/h4\u003e\n\u003cp\u003e\u003cspan style=\"font-weight: 400;\"\u003eIt has cross-linked polyethylene (XLP) insulation. The conductors are normally cabled together with XLP insulated aluminum ground or bare copper ground and covered with reinforced binder tape. XLP insulation is tough and resistant to impact, abrasion, chemicals, acids, oils, industrial solvents, and changes in weather.\u003c\/span\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cp\u003e[\/short]\u003c\/p\u003e\n\u003cp\u003e\u003cb\u003eMV105 OR MV90 Non Shielded XLP 133% Insulation Copper Power Cable 5Kv\u003c\/b\u003e\u003c\/p\u003e\n\u003cp\u003eBeyond any reasonable doubt, the cable is proven to be sturdy and reliable. It has greater convenience and high performance, due to its ease of installation. A cable which is qualified for use in very strenuous and demanding conditions and still guarantees you an everlasting service in your system. This is a cable worth considering.\u003c\/p\u003e\n\u003cp\u003eLet us talk about the spectacular features of this cable.\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cb\u003eConductor\u003c\/b\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eBoth MV105 and MV90 cables are made from copper conductors. The \u003ca href=\"https:\/\/www.nassaunationalcable.com\/wire-and-cable\/copper\/bare.html\"\u003ecopper conductor\u003c\/a\u003e used is soft and annealed. Besides it is bare, that is why the cable is called unshielded. Class B of the conductor used is stranded and compressed according to the provisions of ASTM B-8 or compacted as per the ASTM B-496. This conductor has also a semi-conductor shield which helps to reinforce its efficiency and strength.\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cb\u003eInsulation\u003c\/b\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eTo make the right choice of a cable during your purchase then you should as well check keenly the insulation features of that particular cable. A cable without good and sturdy insulation is destined to ruin your electrical connection. This brand of Nassau National Cable products has a cross-linked polyethylene insulation system. This insulation is designed according to the ICEA regulations.\u003c\/p\u003e\n\u003cp\u003e\u003cb\u003eApplications\u003c\/b\u003e\u003c\/p\u003e\n\u003cp\u003eKnowing where and how to use this cable is extremely vital. Now as I mentioned earlier, load size resonates directly to the type and size of cable to use. This cable is used in power circuits where the voltage rates up to 5 Kilo volts. It is appropriate for installation in open air, conduit and duct installations.\u003c\/p\u003e\n\u003cp\u003eThis power cable has been applied in various systems in chemical plants, various industrial plants, steel mills, refineries, commercial buildings, utility substations and in generator stations. This cable has been tested and proved to work efficiently.\u003c\/p\u003e\n\u003cp\u003e\u003cb\u003e Operation\u003c\/b\u003e\u003c\/p\u003e\n\u003cp\u003eThe National Electric Code, which is a very renowned and accepted standardization body, has approved this cable to be used within 90 degrees Celsius. It can however be used in 130 degrees Celsius emergency overloaded conditions. During a short circuit conditions, the cable can tolerate a temperature of 250 degrees Celsius.\u003c\/p\u003e\n\u003cp style=\"text-align: left;\"\u003e\u003cstrong\u003eQuestion and Answer:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp style=\"text-align: center;\"\u003e\u003cstrong\u003eFrequently Asked Questions - MV105 OR MV90 NON SHIELDED EPR HYPALON HEAVY WALL 133% COPPER CABLE 2.4kV-5kV and MV105 OR MV90 NON SHIELDED XLP 133% INSULATION COPPER CABLE 5KV\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cspan style=\"text-decoration: underline;\"\u003eWhat are the specific applications of MV105 or MV90 Non Shielded EPR Hypalon Heavy Wall 133% Copper 2.4kV-5kV Cables and MV105 or MV90 Non Shielded XLP 133% Insulation Copper cables 5kV?\u003c\/span\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eMV105 or MV90 Non Shielded EPR Hypalon Heavy Wall 133% Copper cable 2.4kV-5kV Cables are suitable for corrosive environments in power circuits up to 2000V which are installed in open air, conduit \u0026amp; duct; cable tray when CT rated, in wet and dry conditions. These power cables are appropriate for chemical plants, refineries, steel mills, industrial plants, commercial buildings, utility substations and general stations.\u003c\/p\u003e\n\u003cp\u003eMV105 or MV90 Non Shielded XLP 133% Insulation Copper cables 5kV also are used in similar situations, just that it can be used in power circuits up to 5000V.\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cspan style=\"text-decoration: underline;\"\u003eWhat type of conductor is used for MV105 or MV90 Non Shielded EPR Hypalon Heavy Wall 133% Copper 2.4kV-5kV Cables and MV105 or MV90 Non Shielded XLP 133% Insulation Copper cables 5kV?\u003c\/span\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe power cables have a semi-conducting conductor shield of soft bare annealed copper which qualify the ASTM B-3. It also has Class B stranding as per ASTM B-8 (compressed) or ASTM B-496 (compact).\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cspan style=\"text-decoration: underline;\"\u003eWhat is the insulation used for MV105 or MV90 Non Shielded EPR Hypalon Heavy Wall 133% Copper 2.4kV-5kV Cables and MV105 or MV90 Non Shielded XLP 133% Insulation Copper cables 5kV?\u003c\/span\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eFor insulation, MV105 or MV90 Non Shielded EPR Hypalon Heavy Wall 133% Copper cable 2.4kV-5kV Cablesuse Ethylene propylene rubber (EPR) per ICEA standards. \u003c\/p\u003e\n\u003cp\u003eMV105 or MV90 Non Shielded XLP 133% Insulation Copper cables 5kV uses Cross-linked polyethylene (XLP) per ICEA regulations.\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cspan style=\"text-decoration: underline;\"\u003eWhat are the regulations and uses of MV105 or MV90 Non Shielded EPR Hypalon Heavy Wall 133% Copper 2.4kV-5kV Cables and MV105 or MV90 Non Shielded XLP 133% Insulation Copper cables 5kVunder specific temperature conditions?\u003c\/span\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe National Electric Code has allowed the use of both thepowercables at 90°C for continuous operation, 130°C for emergency overload conditions and 250°C for short circuit conditions.\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cspan style=\"text-decoration: underline;\"\u003eWhat is the difference between MV105 or MV90 Non Shielded EPR Hypalon Heavy Wall 133% Copper 2.4kV-5kV Cables and MV105 or MV90 Non Shielded XLP 133% Insulation Copper cables 5kV?\u003c\/span\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe main difference between bothcables lies in the fact that MV105 or MV90 Non Shielded EPR Hypalon Heavy Wall 133% Copper cable 2.4kV-5kV Cables have Jacket made of Chloro-sulfonated polyethylene (CSPE\/Hypalon®) as per ICEA standards. It also complies with flame tests - UL and IEEE 383 70,000 BTU\/hr flame test – for CT-listed sizes 1\/0 AWG and larger.\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cspan style=\"text-decoration: underline;\"\u003eWhat are the national and international standards to which MV105 or MV90 Non Shielded EPR Hypalon Heavy Wall 133% Copper 2.4kV-5kV Cables and MV105 or MV90 Non Shielded XLP 133% Insulation Copper cables 5kVconform?\u003c\/span\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eBoth Power Cables conform to all major national and international technical standards of the industry such as:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eICEA S-96-659\u003c\/li\u003e\n\u003cli\u003eUL Standard 1072\u003c\/li\u003e\n\u003cli\u003eNEMA WC71\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Nassau National Cable","offers":[{"title":"Default Title","offer_id":27521970307172,"sku":"NNC5103X","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/products\/Product25.png?v=1762459742","url":"https:\/\/nassaunationalcable.com\/products\/mv105-or-mv90-non-shielded-xlp-133-insulation-copper-cable-2-4kv","provider":"NassauNationalCable","version":"1.0","type":"link"}