{"product_id":"ls-e8fle-023f01ca00-2-awg-strand-al-unfilled-shield-pvc-115mils-series-e8fle-5kv-133-8kv-100-mv-105-power-cable","title":"LS E8FLE-023F01CA00 2 AWG Strand Al Unfilled Shield PVC 115mils Series E8FLE 5kV 133% 8kV 100% MV-105 Power Cable","description":"\u003cstyle type=\"text\/css\"\u003e\u003c!--\ntd {border: 1px solid #cccccc;}br {mso-data-placement:same-cell;}\n--\u003e\u003c\/style\u003e\n\u003cp\u003e\u003cstrong\u003eLS E8FLE-023F01CA00 2 AWG Strand Al Unfilled Shield PVC 115mils Series E8FLE 5kV 133% 8kV 100% MV-105 Power Cable\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eAllowable Ampacity\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e\u003cspan\u003efor LS E8FLE-023F01CA00 2 AWG Strand Al Unfilled Shield PVC 115mils Series E8FLE 5kV 133% 8kV 100% MV-105 Power Cable\u003c\/span\u003e\u003cspan\u003e:\u003c\/span\u003e\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e100 Amps\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eApplicable Standards:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e• In conduit, duct, free air, and raceways, primary installations include cable trays, and outdoor locations\u003cbr\u003e• In direct burial if installed in a system with a ground conductor that is in close proximity, and conforms with NEC 250.4 (A)(5)\u003cbr\u003e• In wet or dry locations\u003cbr\u003e• Approved for Class I, Div. 2 industrial hazardous locations per NEC\u003cbr\u003e• Designed to operate continuously at a conductor temperature not exceeding\u003cbr\u003e» 105°C for normal operations\u003cbr\u003e» 140°C for emergency overload\u003cbr\u003e» 250°C for short circuit\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eAlso Known as:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan data-sheets-userformat='{\"2\":771,\"3\":{\"1\":0},\"4\":{\"1\":2,\"2\":65535},\"11\":3,\"12\":0}' data-sheets-value='{\"1\":2,\"2\":\"Wavenet Stranded Bare Copper Unshielded PVC 300V Audio Cable\"}' data-mce-fragment=\"1\"\u003eMV-105 Cable, LS Cable, E8FLE Cable, Power Cable, LS E8FLE Cable, E8FLE Power Cable\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan data-sheets-value='{\"1\":2,\"2\":\"Wavenet Stranded Bare Copper Unshielded PVC 300V Audio Cable\"}' data-sheets-userformat='{\"2\":771,\"3\":{\"1\":0},\"4\":{\"1\":2,\"2\":65535},\"11\":3,\"12\":0}' data-mce-fragment=\"1\"\u003e\u003cstrong\u003eDescription:\u003cbr\u003e\u003c\/strong\u003e\u003cbr\u003eThe Medium Voltage, EPR\/Cu Tape Shield\/PVC, Type MV-105 Cable consist of fully annealed bare copper Class B stranded conductors, covered with ethylene propylene rubber (EPR), copper tape shield, and black PVC jacket. These cables are used in industrial power circuits.\u003cbr\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan data-sheets-value='{\"1\":2,\"2\":\"Wavenet Stranded Bare Copper Unshielded PVC 300V Audio Cable\"}' data-sheets-userformat='{\"2\":771,\"3\":{\"1\":0},\"4\":{\"1\":2,\"2\":65535},\"11\":3,\"12\":0}' data-mce-fragment=\"1\"\u003e\u003cstrong\u003eFeatures:\u003c\/strong\u003e\u003cbr\u003e\u003cbr\u003e• Rated at 105°C wet or dry\u003cbr data-mce-fragment=\"1\"\u003e• Excellent corona resistance\u003cbr data-mce-fragment=\"1\"\u003e• High dielectric strength\u003cbr data-mce-fragment=\"1\"\u003e• Low moisture absorption\u003cbr data-mce-fragment=\"1\"\u003e• Low dielectric loss\u003cbr\u003e• Excellent sunlight resistance\u003cbr data-mce-fragment=\"1\"\u003e• For CT USE for 1\/0 AWG and larger, per UL® 1072\u003cbr data-mce-fragment=\"1\"\u003e• Meets cold bend test at -35°C\u003cbr\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eSpecification:\u003c\/strong\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eAWG Size:\u003c\/strong\u003e 2\u003cbr\u003e\u003cstrong\u003eInsulation:\u003c\/strong\u003e Ethylene Propylene Rubber (EPR)\u003cbr\u003e\u003cstrong\u003eJacket:\u003c\/strong\u003e Polyvinyl Chloride (PVC)\u003cbr\u003e\u003cstrong data-mce-fragment=\"1\"\u003eNominal Conductor Diameter¹ in (mm):\u003c\/strong\u003e 0.280 (7.1)\u003cbr\u003e\u003cstrong\u003eNominal Insulation Diameter¹ in (mm):\u003c\/strong\u003e 0.563 (14.31)\u003cbr\u003e\u003cstrong\u003eNominal Jacket Thickness¹ in (mm):\u003c\/strong\u003e 0.060 (1.52)\u003cbr\u003e\u003cstrong\u003eNominal Overall Diameter¹ in (mm):\u003c\/strong\u003e 0.806 (20.5)\u003cbr\u003e\u003cstrong data-mce-fragment=\"1\"\u003eAmpacity Conduit in Air²:\u003c\/strong\u003e 130\u003cbr\u003e\u003cstrong\u003eAmpacity Underground Duct³:\u003c\/strong\u003e 130\u003cbr\u003e\u003cstrong\u003eNominal Net Weight:\u003c\/strong\u003e 356 lbs\/kft \u003cbr\u003e\u003cstrong\u003ePart Number:\u003c\/strong\u003e E8FLE-023F01CA00\u003c\/span\u003e\u003c\/p\u003e","brand":"LSCSUSA Cable","offers":[{"title":"Default Title","offer_id":43411120062618,"sku":"","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/products\/cable32_15874ccd-cf4c-4c72-9a38-96563d5a5880.png?v=1762960090","url":"https:\/\/nassaunationalcable.com\/products\/ls-e8fle-023f01ca00-2-awg-strand-al-unfilled-shield-pvc-115mils-series-e8fle-5kv-133-8kv-100-mv-105-power-cable","provider":"NassauNationalCable","version":"1.0","type":"link"}