{"product_id":"indoor-outdoor-distribution-series-ultra-fox-6-fiber-fluoropolymer-singlemode-900µm-tight-buffer-yellow-plenum-cable-dx006kslx9yp","title":"Indoor\/Outdoor Distribution Series Ultra Fox 6 Fiber Fluoropolymer Singlemode 900µm Tight Buffer Yellow Plenum Cable DX006KSLX9YP","description":"\u003cp\u003e[pdf] \u003cembed src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/1_OCC-Catalog_Reduced-Size_Final-34_removed_10_1.pdf?v=1717497825\"\u003e[\/pdf]\u003c\/embed\u003e\u003c\/p\u003e\n\u003ctable style=\"width: 638px;\" width=\"450px\" border=\"1\" cellspacing=\"0\" cellpadding=\"5\" class=\"table\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 303.953px;\" colspan=\"5\"\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 151.953px;\" align=\"center\" colspan=\"2\"\u003e\u003cstrong\u003eTensile Load\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 106.969px;\" align=\"center\" colspan=\"2\"\u003e\u003cstrong\u003eMenimum Bend Radius\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 171.797px;\" colspan=\"3\"\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 60.7812px;\"\u003e\u003cstrong\u003eDiameter\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 71.375px;\" align=\"center\"\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 75px;\"\u003e\u003cstrong\u003eInstallation\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 76.9531px;\"\u003e\u003cstrong\u003eOperational\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 74px;\"\u003e\u003cstrong\u003eInstallation\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 32.9688px;\"\u003e\u003cstrong\u003eLong Term\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr align=\"center\"\u003e\n\u003ctd style=\"width: 39.6875px;\"\u003e\u003cstrong\u003eFiber Count\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 35.2344px;\"\u003e\u003cstrong\u003eFiber Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 96.875px;\"\u003e\u003cstrong\u003ePart Number\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 60.7812px;\"\u003e\u003cstrong\u003emm\/(in)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 71.375px;\"\u003e\u003cstrong\u003ekg\/km (lbs\/1,000)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 75px;\"\u003e\u003cstrong\u003eN (lbs)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 76.9531px;\"\u003e\u003cstrong\u003eN (lbs)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 74px;\"\u003e\u003cstrong\u003ecm (in)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 32.9688px;\"\u003e\u003cstrong\u003ecm (in)\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr align=\"center\"\u003e\n\u003ctd style=\"width: 39.6875px;\"\u003e6\u003c\/td\u003e\n\u003ctd style=\"width: 35.2344px;\"\u003eSLX - SM ITU-T G.652.D\u003c\/td\u003e\n\u003ctd style=\"width: 96.875px;\"\u003eDX006KSLX9YP\u003c\/td\u003e\n\u003ctd style=\"width: 60.7812px;\"\u003e4.8\u003cbr\u003e(0.19)\u003c\/td\u003e\n\u003ctd style=\"width: 71.375px; text-align: center;\"\u003e24.0\u003cbr\u003e(16.80)\u003c\/td\u003e\n\u003ctd style=\"width: 75px;\"\u003e\n\u003cspan\u003e\u003c\/span\u003e1,400\u003cbr\u003e(310)\u003cbr\u003e\n\u003c\/td\u003e\n\u003ctd style=\"width: 76.9531px;\"\u003e450\u003cbr\u003e(100)\u003c\/td\u003e\n\u003ctd style=\"width: 74px;\"\u003e7.2\u003cbr\u003e(2.8)\u003c\/td\u003e\n\u003ctd style=\"width: 32.9688px;\"\u003e7.2\u003cbr\u003e(2.8)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch4\u003e\n\u003cstrong\u003e\u003cbr\u003eAPPLICATIONS:\u003c\/strong\u003e\u003cstrong\u003e\u003c\/strong\u003e\n\u003c\/h4\u003e\n\u003cp\u003e\u003cstrong\u003e•\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003eUsed in trunking, LAN and distribution applications where small size, lightweight, and versatile installation capability are required for ducts, plenums, and air handling spaces\u003cbr\u003e\u003cstrong\u003e•\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003eIdeal configuration for a single termination point requiring multiple fibers\u003cbr\u003e\u003cstrong\u003e•\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003eIndoor\/Outdoor plenum cables eliminate the need for costly cable transitions in different installation environments\u003cstrong\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003ch4\u003e\u003cstrong\u003eSTANDARDS:\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cp\u003eOptical Cable Corporation Indoor\/Outdoor tight buffered fiber optic cables meet the functional requirements of the following standards:\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003e•\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003eUL 1651\u003cbr\u003e\u003cstrong\u003e•\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003eUL 1666\u003cbr\u003e\u003cstrong\u003e•\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003eGR-409-CORE\u003cbr\u003e\u003cstrong\u003e•\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003eICEA-S-104-696\u003cbr\u003e\u003cstrong\u003e•\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003eICEA-S-83-596\u003cbr\u003e\u003cstrong\u003e•\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003eTIA-568\u003cbr\u003e\u003cstrong\u003e•\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003eTIA-598\u003cbr\u003e\u003cstrong\u003e•\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003eUL-listed type OFNR in accordance with NEC sections 770-179 (B) and 770-154 (B) for use in vertical runs in building riser shafts or from floor to floor. Meets or exceeds requirements for intra-building fiber optic cables as outlined in GR-409-CORE.\u003c\/p\u003e\n\u003ch4\u003e\u003cstrong\u003eCHARACTERISTICS:\u003c\/strong\u003e\u003c\/h4\u003e\n\u003ctable width=\"100%\" style=\"width: 78.8321%; height: 196.5px;\"\u003e\n\u003ctbody\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 33.5793%; text-align: center; height: 19.5938px;\"\u003e\u003cstrong\u003eCharacteristic\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 66.0517%; text-align: center; height: 19.5938px;\"\u003e\u003cstrong\u003ePlenum Indoor\/Outdoor (K)\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 33.5793%; text-align: center; height: 19.5938px;\"\u003eOperating Temp\u003c\/td\u003e\n\u003ctd style=\"width: 66.0517%; text-align: center; height: 19.5938px;\"\u003e\u003cspan\u003e-40°C to +85°C\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 33.5793%; text-align: center; height: 19.5938px;\"\u003e\u003cspan\u003eStorage Temp\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 66.0517%; text-align: center; height: 19.5938px;\"\u003e\u003cspan\u003e-40°C to +85°C\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 33.5793%; text-align: center; height: 19.5938px;\"\u003e\u003cspan\u003eInstall Temp\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 66.0517%; text-align: center; height: 19.5938px;\"\u003e\u003cspan\u003e0°C to +60°C\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 39.75px;\"\u003e\n\u003ctd style=\"width: 33.5793%; text-align: center; height: 39.75px;\"\u003e\u003cspan\u003eFlame Retardancy\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 66.0517%; text-align: center; height: 39.75px;\"\u003e\u003cspan\u003eUL Listed Type OFNP (ANSI\/NFPA 262) and FT6 (CSA C22.2 No. 232)\u003cbr\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 33.5793%; text-align: center; height: 19.5938px;\"\u003e\u003cspan\u003eCrush Resist\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 66.0517%; text-align: center; height: 19.5938px;\"\u003e\u003cspan\u003e1500 N\/cm (TIA\/EIA-455-41A)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 33.5793%; text-align: center; height: 19.5938px;\"\u003e\u003cspan\u003eImpact Resist\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 66.0517%; text-align: center; height: 19.5938px;\"\u003e\u003cspan\u003e1000 impacts (EIA\/TIA-455-25A)\u003cbr\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 33.5793%; text-align: center; height: 19.5938px;\"\u003e\u003cspan\u003eFlex Resist\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 66.0517%; text-align: center; height: 19.5938px;\"\u003e\u003cspan\u003e1000 cycles (TIA\/EIA-455-104A)\u003cbr\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 33.5793%; text-align: center; height: 19.5938px;\"\u003e\u003cspan\u003eJacket Type\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 66.0517%; text-align: center; height: 19.5938px;\"\u003e\u003cspan\u003eK\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch4\u003e\u003cstrong\u003e\u003cbr\u003eFEATURES:\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cp\u003e\u003cstrong\u003e•\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003eUL Listed in accordance with NEC section 770.179(a) for use in ducts, plenums and air-handling spaces\u003cbr\u003e\u003cstrong\u003e•\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003eFluorpolymer jacket\u003cbr\u003e\u003cstrong\u003e•\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003e2 to 72 fibers\u003cbr\u003e\u003cstrong\u003e•\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003eCable materials are Indoor\/Outdoor UL-Listed OFNP and also UV, chemical, water and fungus resistant\u003cbr\u003e\u003cstrong\u003e•\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003eJacket is highly chemical resistant for installation in harsh industrial environments\u003cbr\u003e\u003cstrong\u003e•\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003eHigh performance tight-buffered coating on each fiber for environmental and mechanical protection\u003cbr\u003e\u003cstrong\u003e•\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003e900 µm buffer eliminates the need for costly and time-consuming installation of fanout kits or pigtail splices because connectors terminate directly to the fiber.\u003cbr\u003e\u003cstrong\u003e•\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003eHelically stranded core for flexibility, survival in difficult installations, and mechanical protection for the fibers\u003cbr\u003e\u003cstrong\u003e•\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003eHigh specific strength-to-weight ratio and compact cable design for limited conduit space and tight bends in long cable pulls\u003cbr\u003e\u003cstrong\u003e•\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003eHigh crush resistance may eliminate the need for innerduct\u003cbr\u003e\u003cstrong\u003e•\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003eCan be installed outside and in plenum or riser pathways inside, eliminating the need to transition cable types between environments\u003cbr\u003e\u003cstrong\u003e•\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003eInterlocking armor can be applied to cables as an alternative to conduit installation\u003c\/p\u003e","brand":"OPTICAL CA","offers":[{"title":"Default Title","offer_id":44986868072602,"sku":"DX006KSLX9YP","price":1.05,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/105.png?v=1762999478","url":"https:\/\/nassaunationalcable.com\/products\/indoor-outdoor-distribution-series-ultra-fox-6-fiber-fluoropolymer-singlemode-900%c2%b5m-tight-buffer-yellow-plenum-cable-dx006kslx9yp","provider":"NassauNationalCable","version":"1.0","type":"link"}