{"product_id":"indoor-outdoor-breakout-b-series-2-0mm-2-strand-tight-buffered-singlemode-black-jacket-riser-cable-be002dslx9kr","title":"Indoor\/Outdoor Breakout B-Series 2.0mm 2 Strand Tight Buffered Singlemode Black Jacket Riser Cable BE002DSLX9KR","description":"\u003cp\u003e[pdf] \u003cembed src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/OCC-B-SERIES-BREAKOUT-FOTC-Specifications-21.pdf?v=1715332979\"\u003e[\/pdf]\u003c\/embed\u003e\u003c\/p\u003e\n\u003ctable class=\"table\" cellpadding=\"5\" cellspacing=\"0\" border=\"1\" width=\"450px\" style=\"width: 638px;\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"5\" style=\"width: 303.953px;\"\u003e\u003c\/td\u003e\n\u003ctd colspan=\"2\" align=\"center\" style=\"width: 151.953px;\"\u003e\u003cstrong\u003eTensile Load\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd colspan=\"2\" align=\"center\" style=\"width: 106.969px;\"\u003e\u003cstrong\u003eMenimum Bend Radius\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"3\" style=\"width: 171.797px;\"\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 60.7812px;\"\u003e\u003cstrong\u003eDiameter\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd align=\"center\" style=\"width: 71.375px;\"\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 75px;\"\u003e\u003cstrong\u003eInstallation\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 76.9531px;\"\u003e\u003cstrong\u003eOperational\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 74px;\"\u003e\u003cstrong\u003eInstallation\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 32.9688px;\"\u003e\u003cstrong\u003eLong Term\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr align=\"center\"\u003e\n\u003ctd style=\"width: 39.6875px;\"\u003e\u003cstrong\u003eFiber Count\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 35.2344px;\"\u003e\u003cstrong\u003eFiber Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 96.875px;\"\u003e\u003cstrong\u003ePart Number\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 60.7812px;\"\u003e\u003cstrong\u003emm\/(in)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 71.375px;\"\u003e\u003cstrong\u003ekg\/km (lbs\/1,000)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 75px;\"\u003e\u003cstrong\u003eN (lbs)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 76.9531px;\"\u003e\u003cstrong\u003eN (lbs)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 74px;\"\u003e\u003cstrong\u003ecm (in)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 32.9688px;\"\u003e\u003cstrong\u003ecm (in)\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr align=\"center\"\u003e\n\u003ctd style=\"width: 39.6875px;\"\u003e2\u003c\/td\u003e\n\u003ctd style=\"width: 35.2344px;\"\u003eSLX - 62.5µm OM1\u003c\/td\u003e\n\u003ctd style=\"width: 96.875px;\"\u003eBE002DSLX9KR\u003c\/td\u003e\n\u003ctd style=\"width: 60.7812px;\"\u003e6.0\u003cbr\u003e(0.24)\u003c\/td\u003e\n\u003ctd style=\"width: 71.375px;\"\u003e40.0\u003cbr\u003e(28.35)\u003c\/td\u003e\n\u003ctd style=\"width: 75px;\"\u003e\n\u003cspan\u003e\u003c\/span\u003e800\u003cbr\u003e(180)\u003cbr\u003e\n\u003c\/td\u003e\n\u003ctd style=\"width: 76.9531px;\"\u003e200\u003cbr\u003e(40)\u003c\/td\u003e\n\u003ctd style=\"width: 74px;\"\u003e9.0\u003cbr\u003e(3.5)\u003c\/td\u003e\n\u003ctd style=\"width: 32.9688px;\"\u003e6.0\u003cbr\u003e(2.4)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch4 style=\"text-align: left;\" data-mce-style=\"text-align: left;\"\u003e\n\u003cstrong\u003e\u003cbr\u003eAPPLICATIONS:\u003c\/strong\u003e\u003cstrong\u003e\u003c\/strong\u003e\n\u003c\/h4\u003e\n\u003cp\u003e\u003cstrong\u003e• \u003c\/strong\u003eIdeal for installations requiring an extremely rugged and reliable cable design where maximum mechanical and environmental protection are necessary\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003e• \u003c\/strong\u003eTypical industrial uses are factory automation, power generation and other utilities, oil and gas refining, and surface mining\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003e• \u003c\/strong\u003eEasiest cable to install where direct termination of the subcable to a connector and a direct run to panels and equipment are desired\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003e• \u003c\/strong\u003eIdeal for locations requiring low-temperature performance along with a flame rating\u003c\/p\u003e\n\u003ch4\u003e\u003cstrong\u003eSTANDARDS:\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cp\u003eOCC Indoor\/Outdoor tight-buffered fiber optic cables meet the functional requirements of the following standards:\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003e• \u003c\/strong\u003eUL 1666\u003cbr\u003e\u003cstrong\u003e• \u003c\/strong\u003eCSA C22.2 No. 232\u003cbr\u003e\u003cstrong\u003e• \u003c\/strong\u003eCSA C22.2 No. 230\u003cbr\u003e\u003cstrong\u003e• \u003c\/strong\u003eGR-409-CORE\u003cbr\u003e\u003cstrong\u003e• \u003c\/strong\u003eICEA-S-104-696\u003cbr\u003e\u003cstrong\u003e• \u003c\/strong\u003eICEA-S-83-596\u003cbr\u003e\u003cstrong\u003e• \u003c\/strong\u003eTIA-568\u003cbr\u003e\u003cstrong\u003e• \u003c\/strong\u003eTIA-598\u003c\/p\u003e\n\u003ch4\u003e\u003cstrong\u003eCHARACTERISTICS:\u003c\/strong\u003e\u003c\/h4\u003e\n\u003ctable style=\"width: 93.2482%;\" data-mce-style=\"width: 93.2482%;\"\u003e\n\u003ctbody\u003e\n\u003ctr style=\"height: 19.5938px;\" data-mce-style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 22.5743%; text-align: center;\" data-mce-style=\"width: 22.5743%; text-align: center;\"\u003e\u003cstrong\u003eCharacteristics\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 77.0297%; text-align: center;\" data-mce-style=\"width: 77.0297%; text-align: center;\"\u003e\u003cstrong\u003e\u003cspan\u003ePVC Outer Jacket\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\" data-mce-style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 22.5743%; text-align: center;\" data-mce-style=\"width: 22.5743%; text-align: center;\"\u003eOperating Temp\u003c\/td\u003e\n\u003ctd style=\"width: 77.0297%; text-align: center;\" data-mce-style=\"width: 77.0297%; text-align: center;\"\u003e-40°C to +85°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\" data-mce-style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 22.5743%; text-align: center;\" data-mce-style=\"width: 22.5743%; text-align: center;\"\u003eStorage Temp\u003c\/td\u003e\n\u003ctd style=\"width: 77.0297%; text-align: center;\" data-mce-style=\"width: 77.0297%; text-align: center;\"\u003e-55°C to +85°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 44.0529%; text-align: center;\"\u003e\u003cspan\u003eInstall Temp\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 55.0661%; text-align: center;\"\u003e-10°C to +60°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 44.0529%; text-align: center;\"\u003e\u003cspan\u003eFlame Retardancy\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 55.0661%; text-align: center;\"\u003e\u003cspan\u003eUL listed type OFNR (UL 1666) and FT4 (CSA C22.2 No. 232)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\" data-mce-style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 22.5743%; text-align: center;\" data-mce-style=\"width: 22.5743%; text-align: center;\"\u003eCrush Resist\u003c\/td\u003e\n\u003ctd style=\"width: 77.0297%; text-align: center;\" data-mce-style=\"width: 77.0297%; text-align: center;\"\u003e\u003cspan\u003e2200 N\/cm\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\" data-mce-style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 22.5743%; text-align: center;\" data-mce-style=\"width: 22.5743%; text-align: center;\"\u003eImpact Resist\u003c\/td\u003e\n\u003ctd style=\"width: 77.0297%; text-align: center;\" data-mce-style=\"width: 77.0297%; text-align: center;\"\u003e\u003cspan\u003e1500 impacts\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\" data-mce-style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 22.5743%; text-align: center;\" data-mce-style=\"width: 22.5743%; text-align: center;\"\u003eFlex Resist\u003c\/td\u003e\n\u003ctd style=\"width: 77.0297%; text-align: center;\" data-mce-style=\"width: 77.0297%; text-align: center;\"\u003e\u003cspan\u003e2000 cycles\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\" data-mce-style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 22.5743%; text-align: center;\" data-mce-style=\"width: 22.5743%; text-align: center;\"\u003eJacket Type\u003c\/td\u003e\n\u003ctd style=\"width: 77.0297%; text-align: center;\" data-mce-style=\"width: 77.0297%; text-align: center;\"\u003e\u003cspan\u003eD\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch4\u003e\u003cstrong\u003e\u003cbr\u003eFEATURES:\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cp\u003e\u003cstrong\u003e• \u003c\/strong\u003eFiber Optic tray Cable: Suitable for use in cable trays\u003cbr\u003e\u003cstrong\u003e• \u003c\/strong\u003eIndividual fibers and strength members protected in a subcable configuration\u003cbr\u003e\u003cstrong\u003e• \u003c\/strong\u003eMost rugged cable design with individual subcables for routing to diverse intelligent devices with direct connector termination at each device\u003cbr\u003e\u003cstrong\u003e• \u003c\/strong\u003eMeets all applicable standards for Impact \u0026amp; Crush Resistance (CSA C22.2 No. 230)\u003cbr\u003e\u003cstrong\u003e• \u003c\/strong\u003eFibers may be directly terminated at factory devices or central locations using connectors with no further protection required\u003cbr\u003e\u003cstrong\u003e• \u003c\/strong\u003eJ-Jacket is UV, fungus and moisture resistant\u003cbr\u003e\u003cstrong\u003e• \u003c\/strong\u003eDesigned for indoor\/outdoor installations, including cable trays\u003cbr\u003e\u003cstrong\u003e• \u003c\/strong\u003e2 to 72 fiber counts are available with 2.0mm or 2.5mm subcables\u003cbr\u003e\u003cstrong\u003e• \u003c\/strong\u003eLow-temperature PVC outer jacket (J-Jacket) provides excellent performance and flexibility at low temperatures\u003cbr\u003e\u003cstrong\u003e• \u003c\/strong\u003eWide operating temperature range of -50°C to +75°C\u003cbr\u003e\u003cstrong\u003e• \u003c\/strong\u003eCore-locked™ jacket prevents cable from flattening and the jacket from wrinkling in tight bends:\u003cspan\u003e \u003cbr\u003e\u003c\/span\u003e\u003cstrong\u003e• \u003c\/strong\u003ePermits pulling with direct attachment of wire mesh grip; not need to access inner aramid strength members\u003cbr\u003e\u003cstrong\u003e• \u003c\/strong\u003eImproved crush and tear resistance\u003cbr\u003e\u003cstrong\u003e• \u003c\/strong\u003eContains 25% more material than conventional jackets\u003cbr\u003e\u003cstrong\u003e• \u003c\/strong\u003eHigh crush and tensile load ratings compared to similar tray service fiber optic cables\u003cbr\u003e\u003cstrong\u003e• \u003c\/strong\u003eOil resistant for use in industrial applications (J-Jacket)\u003cbr\u003e\u003cstrong\u003e• \u003c\/strong\u003eUL listed in accordance with NEC section 770.179(b) for use in vertical runs in building riser shafts or from floor to floor\u003cbr\u003e\u003cstrong\u003e• \u003c\/strong\u003eDesigned to exceed the flammability requirements of Chapter 8 of IEEE 383\u003cbr\u003e\u003c\/p\u003e","brand":"OPTICAL CA","offers":[{"title":"Default Title","offer_id":44855771857050,"sku":"BE002DSLX9KR","price":0.53,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/55_12999d55-a526-4ea1-93c9-70c4a77ffdcd.png?v=1762997546","url":"https:\/\/nassaunationalcable.com\/products\/indoor-outdoor-breakout-b-series-2-0mm-2-strand-tight-buffered-singlemode-black-jacket-riser-cable-be002dslx9kr","provider":"NassauNationalCable","version":"1.0","type":"link"}