{"product_id":"indoor-outdoor-2-strand-2-0mm-breakout-plenum-multimode-10-gig-om3-aqua-fiber-optic-cable-bx002kalt9qp","title":"Indoor\/Outdoor 2 Strand 2.0mm Breakout Plenum Multimode 10 Gig OM3 Aqua Fiber Optic Cable BX002KALT9QP","description":"\u003cp\u003e[pdf] \u003cembed src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/1_OCC-Catalog_Reduced-Size_Final-34_removed_6_1.pdf?v=1715677477\"\u003e [\/pdf]\u003c\/embed\u003e\u003c\/p\u003e\n\u003ctable width=\"450px\" border=\"1\" cellspacing=\"0\" cellpadding=\"5\" class=\"table\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"4\"\u003e\u003c\/td\u003e\n\u003ctd align=\"center\" colspan=\"2\"\u003e\u003cstrong\u003eTensile Load\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd align=\"center\" colspan=\"2\"\u003e\u003cstrong\u003eMenimum Bend Radius\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\"\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eDiameter\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd align=\"center\"\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eInstallation\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eOperational\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eInstallation\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eLong Term\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr align=\"center\"\u003e\n\u003ctd\u003e\u003cstrong\u003eFiber Count\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003ePart Number\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003emm\/(in)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003ekg\/km (lbs\/1,000)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eN (lbs)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eN (lbs)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003ecm (in)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003ecm (in)\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr align=\"center\"\u003e\n\u003ctd\u003e2\u003c\/td\u003e\n\u003ctd\u003eBX002KALT9QP\u003c\/td\u003e\n\u003ctd\u003e6.3\u003cbr\u003e(0.25)\u003c\/td\u003e\n\u003ctd\u003e46.0\u003cbr\u003e(31.0)\u003c\/td\u003e\n\u003ctd\u003e1,600\u003cbr\u003e(360)\u003c\/td\u003e\n\u003ctd\u003e400\u003cbr\u003e(90)\u003c\/td\u003e\n\u003ctd\u003e9.5\u003cbr\u003e(3.7)\u003c\/td\u003e\n\u003ctd\u003e9.5\u003cbr\u003e(3.7)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch4 style=\"text-align: left;\"\u003e\u003cstrong\u003e\u003cbr\u003eAPPLICATIONS:\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cp\u003e\u003cstrong\u003e•\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003eIdeal for installations requiring an extremely rugged and reliable cable design where maximum mechanical and environmental protection are required \u003cbr\u003e\u003cstrong\u003e•\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003eInstalled in ducts, plenums, and air handling spaces \u003cbr\u003e\u003cstrong\u003e•\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003eEasiest cable to install where direct termination of the subcable to a connector and a direct run to panels and equipment are desired\u003c\/p\u003e\n\u003ch4\u003e\u003cstrong\u003eCost Savings:\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cp\u003e\u003cstrong\u003e•\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003eDirect termination to subcable may eliminate the need for patch panels and patch cords and reduces connector loss \u003cbr\u003e\u003cstrong\u003e•\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003e900 µm buffer eliminates the need for costly and time-consuming installation of fanout kits or pigtail splices because connectors terminate directly to the subcable \u003cbr\u003e\u003cstrong\u003e•\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003eHigh crush resistance may eliminate the need for innerduct\u003c\/p\u003e\n\u003ch4\u003e\u003cstrong\u003eSTANDARDS:\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cp\u003eOptical Cable Corporation Indoor\/Outdoor tight-buffered fiber optic cables meet the functional requirement of the following standards:\u003cbr\u003e\u003cstrong\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003e•\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003eUL 1651 \u003cbr\u003e\u003cstrong\u003e•\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003eANSI\/NFPA 262 \u003cbr\u003e\u003cstrong\u003e•\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003eGR-409-CORE \u003cbr\u003e\u003cstrong\u003e•\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003eICEA-S-104-696 \u003cbr\u003e\u003cstrong\u003e•\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003eICEA-S-83-596 \u003cbr\u003e\u003cstrong\u003e•\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003eTIA-568 \u003cbr\u003e\u003cstrong\u003e•\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003eTIA-598\u003c\/p\u003e\n\u003ch4\u003e\u003cstrong\u003eCHARACTERISTICS:\u003c\/strong\u003e\u003c\/h4\u003e\n\u003ctable style=\"width: 55.4745%; height: 97.969px;\" width=\"100%\"\u003e\n\u003ctbody\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 47.9667%; text-align: center; height: 19.5938px;\"\u003e\u003cstrong\u003eCharacteristic\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 51.3622%; text-align: center; height: 19.5938px;\"\u003e\u003cstrong\u003ePlenum\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 47.9667%; text-align: center; height: 19.5938px;\"\u003eOperating Temp\u003c\/td\u003e\n\u003ctd style=\"width: 51.3622%; text-align: center; height: 19.5938px;\"\u003e-40°C to +85°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 47.9667%; text-align: center; height: 19.5938px;\"\u003e\u003cspan\u003eStorage Temp\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 51.3622%; text-align: center; height: 19.5938px;\"\u003e\u003cspan\u003e-40°C to +85°C\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 47.9667%; text-align: center; height: 19.5938px;\"\u003e\u003cspan\u003eInstall Temp\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 51.3622%; text-align: center; height: 19.5938px;\"\u003e\u003cspan\u003e0°C to +60°C\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 47.9667%; text-align: center; height: 19.5938px;\"\u003e\u003cspan\u003eFlame Retardancy\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 51.3622%; text-align: center; height: 19.5938px;\"\u003e\u003cspan\u003eUL Listed Type OFNP (ANSI\/NFPA 262) and FT6 (CSA C22.2 No. 232)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 47.9667%; text-align: center;\"\u003e\u003cspan\u003eCrush Resist\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 51.3622%; text-align: center;\"\u003e\u003cspan\u003e2100 N\/cm\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 47.9667%; text-align: center;\"\u003e\u003cspan\u003eImpact Resist\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 51.3622%; text-align: center;\"\u003e\u003cspan\u003e1000 impacts\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 47.9667%; text-align: center;\"\u003e\u003cspan\u003eFlex Resist\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 51.3622%; text-align: center;\"\u003e\u003cspan\u003e2000 cycles\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 47.9667%; text-align: center;\"\u003e\u003cspan\u003eJacket Type\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 51.3622%; text-align: center;\"\u003e\u003cspan\u003eK\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch4\u003e\u003cstrong\u003e\u003cbr\u003eFEATURES:\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cp\u003e\u003cstrong\u003e•\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003eHigh performance components and construction\u003cbr\u003e\u003cstrong\u003e•\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003eUL Listed in accordance with NEC sections 770.179(a) for use in ducts, plenums and air-handling spaces\u003cbr\u003e\u003cstrong\u003e•\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003eMost rugged and easy to install cable design for enterprise cabling applications\u003cbr\u003e\u003cstrong\u003e•\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003eStandard 2.0mm subcables can be directly terminated with standard connectors. 2.5mm and 2.9mm subcable sizes are also available\u003cbr\u003e\u003cstrong\u003e•\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003eSubcabled fiber is environmentally and mechanically protected\u003cbr\u003e\u003cstrong\u003e•\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003eIdeal for use in point-to-point runs in adverse environments\u003cbr\u003e\u003cstrong\u003e•\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003eDirect termination to subcable provides additional strain relief for better connector retention during moves, adds, and changes\u003cbr\u003e\u003cstrong\u003e•\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003eDesign is ideal for direct pulling with mesh grips\u003cbr\u003e\u003cstrong\u003e•\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003eCable materials are Indoor\/Outdoor - UV, water and fungus resistant\u003cbr\u003e\u003cstrong\u003e•\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003eWide operating temperature range of -40°C to +85°C\u003cbr\u003e\u003cstrong\u003e•\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003eHigh performance 900 µm tight-buffered coating on each optical fiber for environmental and mechanical protection\u003cbr\u003e\u003cstrong\u003e•\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003eJacket highly chemical resistant for installation in harsh industrial environments\u003cbr\u003e\u003cstrong\u003e•\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003eInterlocking armor can be applied to cables as an alternative to conduit installation\u003cbr\u003e\u003cstrong\u003e•\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003e2 to 48 fibers\u003c\/p\u003e","brand":"OPTICAL CA","offers":[{"title":"Default Title","offer_id":44869056463002,"sku":"BX002KALT9QP","price":1.47,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/62_8693138d-a383-4a6f-bb3d-4903e9e5f7bb.png?v=1762997814","url":"https:\/\/nassaunationalcable.com\/products\/indoor-outdoor-2-strand-2-0mm-breakout-plenum-multimode-10-gig-om3-aqua-fiber-optic-cable-bx002kalt9qp","provider":"NassauNationalCable","version":"1.0","type":"link"}