{"product_id":"hvteck-aluminum-3-c-115-mil-nlepr-ts-aia-5kv-133-il-orange-pvc-jacket-csa-1","title":"HVTECK Aluminum 3\/C 115 mil NLEPR TS AIA 5kV 133% IL Orange PVC Jacket CSA","description":"\u003cp\u003e[pdf] \u003cembed src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/SOUTHWIRE_SPEC26162_1.pdf?v=1790060425\"\u003e [\/pdf]\u003c\/embed\u003e\u003c\/p\u003e\n\u003ch2\u003e\u003cspan\u003eHVTECK Aluminum 3\/C 115 mil NLEPR TS AIA 5kV 133% IL Orange PVC Jacket CSA\u003c\/span\u003e\u003c\/h2\u003e\n\u003ch3\u003e\u003cspan\u003eApplication:\u003c\/span\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cspan\u003eThe 5kV HVTECK is a CSA armoured cable for industrial and commercial medium voltage applications. Rated FT4, -40°C, Hazardous Locations (HL). These cables are capable of operating continuously at the conductor temperature not in excess of 105°C for normal operation, 140°C for emergency overload, and 250°C for short circuit conditions. Rated for 1000 lbs \/FT maximum sidewall pressure. These cables feature sunlight and moisture resistance, exceptional corona resistance, resistance to most chemical soils and acids and are flame retardant. 3 Conductor, 115 Mils No Lead Ethylene Propylene Rubber (NL-EPR), 133% Insulation Level, Tape Shield, Polyvinyl Chloride (PVC) Inner Jacket, Aluminum Interlocked Armour (AIA), Polyvinyl Chloride (PVC) Jacket.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cspan\u003eAlso Known as:\u003c\/span\u003e\u003c\/h3\u003e\n\u003cp\u003e5kV HVTECK Cable, \u003cspan class=\"PDq2pG_selectionAnchor\"\u003e\u003c\/span\u003e5kV HVTECK Armoured Cable, 5kV CSA Armoured Cable, 5kV Medium Voltage Cable, 5kV MV Power Cable, 5kV Shielded Power Cable, 5kV 3\/C Aluminum Cable, 3\/C Aluminum Medium Voltage Cable, Aluminum Armoured MV Cable, Aluminum Interlocked Armour Cable, AIA Armoured Cable, 5kV AIA Cable, NL-EPR Insulated Cable, 115 mil EPR Cable,133% Insulation Level Cable, Copper Tape Shielded Cable, PVC Jacketed Armoured Cable, Orange PVC Jacket Cable, CSA HVTECK Cable\u003c\/p\u003e\n\u003ch3\u003eConstruction:\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eConductor:\u003c\/strong\u003e Class B compact stranded 8000 Series aluminum per ASTM B800 and ASTM\u003cbr\u003eB836\u003cbr\u003e\u003cstrong\u003eConductor Shield:\u003c\/strong\u003e Semi-conducting cross-linked copolymer; A conductor separator is used for cable size larger than or equal to 500 Kcmil\u003cbr\u003e\u003cstrong\u003eInsulation:\u003c\/strong\u003e 115 Mils No Lead Ethylene Propylene Rubber (NL-EPR) 133% insulation level\u003cbr\u003e\u003cstrong\u003eInsulation Shield:\u003c\/strong\u003e Strippable semi-conducting cross-linked copolymer\u003cbr\u003e\u003cstrong\u003eCopper Tape Shield:\u003c\/strong\u003e Helically wrapped 5 mil copper tape with 25% overlap\u003cbr\u003e\u003cstrong\u003eFiller:\u003c\/strong\u003e Interstices filled with non-hydroscoping\/non-wicking fillers\u003cbr\u003e\u003cstrong\u003eGrounding Conductor:\u003c\/strong\u003e Class B compressed stranded bare copper ground per ASTM B3 and ASTM B8\u003cbr\u003e\u003cstrong\u003eBinder:\u003c\/strong\u003e Polypropylene tape \u003cbr\u003e\u003cstrong\u003eInner Jacket:\u003c\/strong\u003e PVC inner jacket\u003cbr\u003e\u003cstrong\u003eArmour:\u003c\/strong\u003e Aluminum Interlocked Armour (AIA)\u003cbr\u003e\u003cstrong\u003eOverall Jacket:\u003c\/strong\u003e Orange Polyvinyl Chloride (PVC) Jacket.\u003c\/p\u003e\n\u003ch3\u003eStandards:\u003c\/h3\u003e\n\u003cp\u003e ASTM B801 Concentric-Lay-Stranded Conductors of 8000 Series Aluminum Alloy\u003cbr\u003e ASTM B836 Compact Rounded Stranded Aluminum Conductors\u003cbr\u003e CSA C22.2 No. 174 Cables in Hazardous Locations\u003cbr\u003e CSA C22.2 No. 2556 \u0026amp; No. 0.3 Wire and Cable Test Methods\u003cbr\u003e CSA C68.10 Shielded Power Cables for Commercial and Industrial Applications - 5 to 46 KV\u003cbr\u003e CSA C68.3 Shielded \u0026amp; Concentric Neutral Power Cable - 5 to 46 kV\u003cbr\u003e CSA LTGG [-40°C] - as per C68.10 - for Cold Bend and Impact rating\u003cbr\u003e CSA HL - for Hazardous Locations rating\u003cbr\u003e CSA SUN RES - for Sunlight Resistant rating\u003cbr\u003e ICEA S-93-639 (NEMA WC 74) 5-46 KV Shielded Power Cable\u003cbr\u003e ICEA T-29-520 Flame Test (210,000 BTU\/Hr)\u003cbr\u003e IEEE 383 Flame Test (70,000 btu)\u003cbr\u003e IEEE 1202 FT4 Flame Test (70,000) BTU\/hr Vertical Tray Test\u003cbr\u003e FT1 Flame Test (1,706 BTU\/Hr nominal - Vertical Wire Flame Test)\u003cbr\u003e AEIC CS-8 Specification for extruded dielectric shielded power cables rated for 5 through   46KV (Qualification Test Requirements).\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e\u003cbr\u003e\u003c\/span\u003e\u003c\/p\u003e","brand":"Nassau National Cable","offers":[{"title":"Default Title","offer_id":64644267180401,"sku":null,"price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/Untitled_design_16_800x800_d51935d7-f4dd-4212-8ff7-7ca1fd9d79e4.png?v=1790057710","url":"https:\/\/nassaunationalcable.com\/products\/hvteck-aluminum-3-c-115-mil-nlepr-ts-aia-5kv-133-il-orange-pvc-jacket-csa-1","provider":"NassauNationalCable","version":"1.0","type":"link"}