{"product_id":"fluke-287-true-rms-electronics-logging-multimeter","title":"Fluke 287 True-RMS Electronics Logging Multimeter","description":"\u003ctable style=\"width: 99.246%;\" data-mce-fragment=\"1\"\u003e\n\u003ctbody data-mce-fragment=\"1\"\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd style=\"width: 32.0583%; text-align: center;\" data-mce-fragment=\"1\"\u003eMaximum voltage between any terminal and earth ground\u003c\/td\u003e\n\u003ctd style=\"width: 64.4555%; text-align: center;\" data-mce-fragment=\"1\"\u003e1000 V\u003cbr\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd style=\"width: 32.0583%; text-align: center;\" data-mce-fragment=\"1\"\u003eBattery type\u003c\/td\u003e\n\u003ctd style=\"width: 64.4555%; text-align: center;\" data-mce-fragment=\"1\"\u003e6 AA alkaline batteries, IECLR6\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd style=\"width: 32.0583%; text-align: center;\" data-mce-fragment=\"1\"\u003eTemperature\u003c\/td\u003e\n\u003ctd style=\"width: 64.4555%; text-align: center;\" data-mce-fragment=\"1\"\u003e-20°C to 55°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd style=\"width: 32.0583%; text-align: center;\" data-mce-fragment=\"1\"\u003eRelative humidity\u003c\/td\u003e\n\u003ctd style=\"width: 64.4555%; text-align: center;\" data-mce-fragment=\"1\"\u003e0 to 90% (0 t 37°C), 0 to 65% (37°C to 45°C), 0 to 45% (45°C to 55°C)\u003cbr\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd style=\"width: 32.0583%; text-align: center;\" data-mce-fragment=\"1\"\u003eElectromagnetic compatibility\u003c\/td\u003e\n\u003ctd style=\"width: 64.4555%; text-align: center;\" data-mce-fragment=\"1\"\u003eEMC EN61326–1\u003cbr\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd style=\"width: 32.0583%; text-align: center;\" data-mce-fragment=\"1\"\u003eVibration\u003c\/td\u003e\n\u003ctd style=\"width: 64.4555%; text-align: center;\" data-mce-fragment=\"1\"\u003eRandom vibration per MIL-PRF-28800F Class 2\u003cbr\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd style=\"width: 32.0583%; text-align: center;\" data-mce-fragment=\"1\"\u003eShock\u003c\/td\u003e\n\u003ctd style=\"width: 64.4555%; text-align: center;\" data-mce-fragment=\"1\"\u003e1 meter drop per IEC\/EN 61010–1 3rd Edition\u003cbr\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd style=\"width: 32.0583%; text-align: center;\" data-mce-fragment=\"1\"\u003eTrue-RMS AC bandwidth\u003c\/td\u003e\n\u003ctd style=\"width: 64.4555%; text-align: center;\" data-mce-fragment=\"1\"\u003e100 kHz\u003cbr\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd style=\"width: 32.0583%; text-align: center;\" data-mce-fragment=\"1\"\u003eDC mV resolution\u003c\/td\u003e\n\u003ctd style=\"width: 64.4555%; text-align: center;\" data-mce-fragment=\"1\"\u003e1 μV\u003cbr\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd style=\"width: 32.0583%; text-align: center;\" data-mce-fragment=\"1\"\u003eMegohm range\u003c\/td\u003e\n\u003ctd style=\"width: 64.4555%; text-align: center;\" data-mce-fragment=\"1\"\u003eUp to 500 MΩ\u003cbr\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd style=\"width: 32.0583%; text-align: center;\" data-mce-fragment=\"1\"\u003ePulse width\u003c\/td\u003e\n\u003ctd style=\"width: 64.4555%; text-align: center;\" data-mce-fragment=\"1\"\u003e0.025 ms, 0.25 ms, 2.5 ms, 1250.0 ms\u003cbr\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd style=\"width: 32.0583%; text-align: center;\" data-mce-fragment=\"1\"\u003eDC volts\u003c\/td\u003e\n\u003ctd style=\"width: 64.4555%; text-align: center;\" data-mce-fragment=\"1\"\u003eRange \/ resolution : 50.000 mV, 500.00 mV, 5.0000 V, 50.000 V, 500.00 V, 1000.0 V\u003cbr\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd style=\"width: 32.0583%; text-align: center;\" data-mce-fragment=\"1\"\u003eAC volts\u003c\/td\u003e\n\u003ctd style=\"width: 64.4555%; text-align: center;\" data-mce-fragment=\"1\"\u003eRange \/ resolution : 50.000 mV, 500.00 mV, 5.0000 V, 50.000 V, 500.00 V, 1000.0 V\u003cbr data-mce-fragment=\"1\"\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd style=\"width: 32.0583%; text-align: center;\" data-mce-fragment=\"1\"\u003eDC current\u003c\/td\u003e\n\u003ctd style=\"width: 64.4555%; text-align: center;\" data-mce-fragment=\"1\"\u003eRange \/ resolution : 500.00 μA, 5000.0 μA, 50.000 mA, 400.00 mA, 5.0000 A, 10.000 A\u003cbr data-mce-fragment=\"1\"\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd style=\"width: 32.0583%; text-align: center;\" data-mce-fragment=\"1\"\u003eAC current\u003c\/td\u003e\n\u003ctd style=\"width: 64.4555%; text-align: center;\" data-mce-fragment=\"1\"\u003eRange \/ resolution : 500.00 μA, 5000.0 μA, 50.000 mA, 400.00 mA, 5.0000 A, 10.000 A\u003cbr data-mce-fragment=\"1\"\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd style=\"width: 32.0583%; text-align: center;\" data-mce-fragment=\"1\"\u003eResistance\u003c\/td\u003e\n\u003ctd style=\"width: 64.4555%; text-align: center;\" data-mce-fragment=\"1\"\u003e500.00 Ω, 5.0000 kΩ, 50.000 kΩ, 500.00 kΩ, 5.0000 MΩ, 50.00 MΩ, 500.0 MΩ\u003cbr\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd style=\"width: 32.0583%; text-align: center;\" data-mce-fragment=\"1\"\u003eCapacitance\u003c\/td\u003e\n\u003ctd style=\"width: 64.4555%; text-align: center;\" data-mce-fragment=\"1\"\u003e1.000 n, 10.00 nF, 100.0 nF, 1.000 μF, 10.00 μF, 100.0 μF, 1000 μF, 10.00 mF, 100 mF\u003cbr\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd style=\"width: 32.0583%; text-align: center;\" data-mce-fragment=\"1\"\u003eFrequency\u003c\/td\u003e\n\u003ctd style=\"width: 64.4555%; text-align: center;\" data-mce-fragment=\"1\"\u003e99.999 Hz, 999.99 Hz, 9.9999 kHz, 99.999 kHz, 999.99 kHz\u003cbr\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd style=\"width: 32.0583%; text-align: center;\" data-mce-fragment=\"1\"\u003eConnectivity\u003c\/td\u003e\n\u003ctd style=\"width: 64.4555%; text-align: center;\" data-mce-fragment=\"1\"\u003eOptional infrared connector via Fluke ir3000 FC\u003cbr\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd style=\"width: 32.0583%; text-align: center;\" data-mce-fragment=\"1\"\u003ePart Number \u003c\/td\u003e\n\u003ctd style=\"width: 64.4555%; text-align: center;\" data-mce-fragment=\"1\"\u003e FLUKE 287\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp style=\"text-align: center;\"\u003e\u003cstrong\u003eFLUKE 287 TRUE-RMS ELECTRONICS LOGGING MULTIMETER \u003c\/strong\u003e\u003c\/p\u003e\n\u003ch4\u003eDescription :-\u003c\/h4\u003e\n\u003cp\u003eThe Fluke 287 True-rms Electronics Logging Multimeter with TrendCapture quickly documents design performance and graphically displays what happened. Its unique logging and graphing capabilities mean you no longer need to download logged readings to a PC to detect a trend. The Fluke 287 packs more accuracy and convenience into a handheld multimeter than ever before.\u003cbr\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003ch4\u003eKey Features :-\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003e( * ) \u003c\/strong\u003eZoom on trend provides unprecedented ability to view and analyze TrendCapture data; zoom in up to 14 times.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong data-mce-fragment=\"1\"\u003e( * ) \u003c\/strong\u003eSelectable AC filter (smoothing mode) helps display a steadier reading when the input signal is changing rapidly or noisy.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong data-mce-fragment=\"1\"\u003e( * ) \u003c\/strong\u003eAdjustable recording and auto hold thresholds, specify a percentage change in the readings that begins a new event.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong data-mce-fragment=\"1\"\u003e( * ) \u003c\/strong\u003eLarge 50,000 count, 1\/4 VGA display with white backlight. Multiple sets of measurement information can be simultaneously displayed at the same time.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong data-mce-fragment=\"1\"\u003e( * ) \u003c\/strong\u003eLogging function with expanded memory for unattended monitoring of signals over time. Using on-board TrendCapture users can graphically review logged readings without needing a PC. Store up to 15,000 recorded events.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong data-mce-fragment=\"1\"\u003e( * ) \u003c\/strong\u003eOn board help screens for measurement functions.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong data-mce-fragment=\"1\"\u003e( * ) \u003c\/strong\u003eSaved measurements allow you to name and recall measurements made in the field.\u003cstrong data-mce-fragment=\"1\"\u003e( * ) \u003c\/strong\u003eMulti-lingual interface.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong data-mce-fragment=\"1\"\u003e( * ) \u003c\/strong\u003eMultiple logging sessions possible without download.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong data-mce-fragment=\"1\"\u003e( * ) \u003c\/strong\u003e0.025% basic DC accuracy.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong data-mce-fragment=\"1\"\u003e( * ) \u003c\/strong\u003e100 kHz AC bandwidth.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong data-mce-fragment=\"1\"\u003e( * ) \u003c\/strong\u003eReal time clock for automatic time stamping of saved readings.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong data-mce-fragment=\"1\"\u003e( * ) \u003c\/strong\u003eTrue-RMS AC voltage and current for accurate measurements on complex signals or \u003cstrong data-mce-fragment=\"1\"\u003e( * ) \u003c\/strong\u003enon-linear loads. AC bandwidth specified to 100 kHz.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong data-mce-fragment=\"1\"\u003e( * ) \u003c\/strong\u003eMeasure up to 10 A (20 A for 30 seconds).\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong data-mce-fragment=\"1\"\u003e( * ) \u003c\/strong\u003e100 mF capacitance range.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong data-mce-fragment=\"1\"\u003e( * ) \u003c\/strong\u003eTemperature function.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong data-mce-fragment=\"1\"\u003e( * ) \u003c\/strong\u003eRelative mode to remove test lead resistance from low ohms or capacitance        measurements. • Peak capture to record transients as fast as 250 μs.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong data-mce-fragment=\"1\"\u003e( * ) \u003c\/strong\u003ePremium test leads and alligator clips included.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong data-mce-fragment=\"1\"\u003e( * ) \u003c\/strong\u003eAmp jack plugs included.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong data-mce-fragment=\"1\"\u003e( * ) \u003c\/strong\u003eOptional FlukeView forms enable you to document, store and analyze individual readings or a series of measurements, then convert them into professional-looking documents.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong data-mce-fragment=\"1\"\u003e( * ) \u003c\/strong\u003eOptional magnetic hanger allows you to hang the meter for easy viewing while freeing your hands to focus on the job.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e \u003c\/p\u003e","brand":"Wire Xpress","offers":[{"title":"Default Title","offer_id":44340799537306,"sku":"FLUKE 287","price":1066.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/Fluke2875.png?v=1762989374","url":"https:\/\/nassaunationalcable.com\/products\/fluke-287-true-rms-electronics-logging-multimeter","provider":"NassauNationalCable","version":"1.0","type":"link"}