{"product_id":"data-center-electrical-utility-kit-tk-dc02","title":"Data Center Electrical Utility Kit TK-DC02","description":"\u003ctable width=\"100%\" style=\"width: 80.1922%; height: 764.381px;\"\u003e\n\u003ctbody\u003e\n\u003ctr style=\"height: 19.5995px;\"\u003e\n\u003ctd style=\"width: 48.7971%; text-align: center; height: 19.5995px;\"\u003e\u003cstrong\u003eType\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 50.8075%; text-align: center; height: 19.5995px;\"\u003eElectrical Utility Kit\u003cbr\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5995px;\"\u003e\n\u003ctd style=\"width: 48.7971%; text-align: center; height: 19.5995px;\"\u003e\u003cstrong\u003eUPC\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 50.8075%; text-align: center; height: 19.5995px;\"\u003e\u003cspan\u003e810215350551\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 58.7985px;\"\u003e\n\u003ctd style=\"width: 48.7971%; text-align: center; height: 58.7985px;\"\u003e\u003cstrong\u003eData Center Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 50.8075%; text-align: center; height: 58.7985px;\"\u003e\u003cspan style=\"font-size: 0.875rem;\"\u003eTraditional (Edge, Enterprise, Colocation), Hyperscale (Cloud, Large-Scale), AI Network (Campus\/GPU Clusters)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 58.7985px;\"\u003e\n\u003ctd style=\"width: 48.7971%; text-align: center; height: 58.7985px;\"\u003e\u003cstrong\u003eEnvironment Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 50.8075%; text-align: center; height: 58.7985px;\"\u003e\u003cspan style=\"font-size: 0.875rem;\"\u003eAll Environments (Inside Plant (ISP), Outside Plant to Inside Plant (OSP-to-ISP) \u0026amp; Outside Plant (OSP)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5995px;\"\u003e\n\u003ctd style=\"width: 48.7971%; text-align: center; height: 19.5995px;\"\u003e\u003cstrong\u003eSolutions Focus\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 50.8075%; text-align: center; height: 19.5995px;\"\u003e\u003cspan style=\"font-size: 0.875rem;\"\u003eOperations \u0026amp; Power\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 39.199px;\"\u003e\n\u003ctd style=\"width: 48.7971%; text-align: center; height: 39.199px;\"\u003e\u003cstrong\u003eLifecycle Phase\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 50.8075%; text-align: center; height: 39.199px;\"\u003e\u003cspan style=\"font-size: 0.875rem;\"\u003eAll Phases (Prep \u0026amp; Install, Testing \u0026amp; Commission, Repair \u0026amp; Maintenance)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 58.7985px;\"\u003e\n\u003ctd style=\"width: 48.7971%; text-align: center; height: 58.7985px;\"\u003e\u003cstrong\u003eCapabilities\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 50.8075%; text-align: center; height: 58.7985px;\"\u003e\u003cspan style=\"font-size: 0.875rem;\"\u003eBend, crimp, cut, drive, electrical testing, grip, illuminate, pull, strip, store \u0026amp; carry, terminate\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 58.7985px;\"\u003e\n\u003ctd style=\"width: 48.7971%; text-align: center; height: 58.7985px;\"\u003e\u003cstrong\u003eCrimping Capabilities\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 50.8075%; text-align: center; height: 58.7985px;\"\u003e\u003cspan style=\"font-size: 0.875rem;\"\u003eInsulated butt connectors, telephone spade lugs, open barrel connectors, and non-insulated lugs\/terminals\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 97.9976px;\"\u003e\n\u003ctd style=\"width: 48.7971%; text-align: center; height: 97.9976px;\"\u003e\u003cstrong\u003eCutting Capabilities\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 50.8075%; text-align: center; height: 97.9976px;\"\u003e\u003cspan style=\"font-size: 0.875rem;\"\u003eSide-Cut: Live Wire (up to 1000V) \u0026amp; high-strength wire, bolts, nails; Flush Cut: Live Wire (up to 1000V) \u0026amp; high-strength wire, bolts, nails; Diagonal Cut: Live Wire (up to 1000V)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 58.7985px;\"\u003e\n\u003ctd style=\"width: 48.7971%; text-align: center; height: 58.7985px;\"\u003e\u003cstrong\u003eDriver Specs\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 50.8075%; text-align: center; height: 58.7985px;\"\u003e\u003cspan style=\"font-size: 0.875rem;\"\u003eLive Circuits (up to 1000V): Phillips: #1 x 3\"\", #2 x 4\"\", #3 x 6\"\" Cabinet Slotted: 5\/32\"\" x 4\"\", 1\/4\"\" x 6\"\", 5\/16\"\" x 7\"\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 58.7985px;\"\u003e\n\u003ctd style=\"width: 48.7971%; text-align: center; height: 58.7985px;\"\u003e\u003cstrong\u003eElectrical Testing Capabilities\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 50.8075%; text-align: center; height: 58.7985px;\"\u003e\u003cspan style=\"font-size: 0.875rem;\"\u003eDC\/AC Current, DC\/AC Voltage, Resistance, Capacitance, Temperature, Continuity\/Diode, up to 2500V \u0026amp; 999.9A\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5995px;\"\u003e\n\u003ctd style=\"width: 48.7971%; text-align: center; height: 19.5995px;\"\u003e\u003cstrong\u003eIlluminating Capabilities\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 50.8075%; text-align: center; height: 19.5995px;\"\u003e\u003cspan style=\"font-size: 0.875rem;\"\u003e250-1500 lm, 4-8 hrs\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 39.199px;\"\u003e\n\u003ctd style=\"width: 48.7971%; text-align: center; height: 39.199px;\"\u003e\u003cstrong\u003ePulling \u0026amp;amp; Gripping Capabilities\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 50.8075%; text-align: center; height: 39.199px;\"\u003e\u003cspan style=\"font-size: 0.875rem;\"\u003eSteel Fishtape: 1\/8-1\/4\" (3.18-6.35 mm) Live wire (up to 1000V) \u0026amp; general materials\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 78.3981px;\"\u003e\n\u003ctd style=\"width: 48.7971%; text-align: center; height: 78.3981px;\"\u003e\u003cstrong\u003eStripping Capabilities\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 50.8075%; text-align: center; height: 78.3981px;\"\u003e\u003cspan style=\"font-size: 0.875rem;\"\u003eRound cable: 3\/16-1-1\/8\" (4.76-28.58 mm) diameter Wire: 10-30 AWG (2.6-0.5 mm) solid or stranded Live Wire (up to 1000V): 8-30 AWG (3.26-0.25 mm) solid or stranded\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 39.199px;\"\u003e\n\u003ctd style=\"width: 48.7971%; text-align: center; height: 39.199px;\"\u003e\u003cstrong\u003eTerminating Capabilities\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 50.8075%; text-align: center; height: 39.199px;\"\u003e\u003cspan style=\"font-size: 0.875rem;\"\u003eRing, Fork, Spade \u0026amp; Butt-Splice, 10-22 AWG (2.6- 0.64 mm)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5995px;\"\u003e\n\u003ctd style=\"width: 48.7971%; text-align: center; height: 19.5995px;\"\u003e\u003cstrong\u003eRemoval Capabilities\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 50.8075%; text-align: center; height: 19.5995px;\"\u003e\u003cspan style=\"font-size: 0.875rem;\"\u003eSlit : PVC, Rubber, PE Spiral: PVC, Rubber, PE Ring: PVC, Rubber, PE Strip: PVC, Rubber, PE\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5995px;\"\u003e\n\u003ctd style=\"width: 48.7971%; text-align: center; height: 19.5995px;\"\u003e\u003cstrong\u003ePart Number\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 50.8075%; text-align: center; height: 19.5995px;\"\u003e\u003cspan style=\"font-size: 0.875rem;\"\u003eTK-DC02\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e\u003cstrong style=\"font-size: 0.875rem;\"\u003e\u003cbr\u003eData Center Electrical Utility Kit\u003cbr\u003e\u003cbr\u003e\u003c\/strong\u003e\u003cstrong\u003eDescription:\u003cbr\u003e\u003cbr\u003e\u003c\/strong\u003eThe Jonard Tools TK-DC02 is a purpose-built electrical termination and power distribution kit designed for technicians installing, connecting, and maintaining power infrastructure in and around modern data center facilities. It is suited for a wide range of environments, including edge and enterprise data centers, hyperscale facilities, colocation sites, and AI infrastructure.\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003eFeatures:\u003cbr\u003e\u003cbr\u003e\u003c\/strong\u003e⦿\u003cstrong\u003e \u003c\/strong\u003eStrip and prepare wires across a wide range of gauges: The CST-1900 handles round cables from 3\/16\" to 1-1\/8\", while the JIC-2030 supports 20–30 AWG signal wires, the WSS-1020 covers 10–20 AWG, and the INP-4065 enables live-wire stripping across 8–30 AWG.\u003cbr\u003e\u003cbr\u003e⦿\u003cstrong\u003e \u003c\/strong\u003eWork safely in live and mixed-voltage environments: A comprehensive insulated tool set includes the INP-1072 combination plier, INP-2065 long-nose plier, INP-3062 diagonal plier, and a complete range of insulated Phillips and slotted screwdrivers, including INS-180, INS-2100, INS-3150, INS-4100, INS-475, INS-6150, and INS-8175.\u003cbr\u003e\u003cbr\u003e⦿\u003cstrong\u003e \u003c\/strong\u003ePull, route, and manage wires through tight pathways: The JIC-685 lineman’s pliers feature an integrated fish-tape puller and crimper, helping technicians manage wiring from conduit entry through final termination.\u003cbr\u003e\u003cbr\u003e⦿\u003cstrong\u003e \u003c\/strong\u003eCrimp and terminate connections with confidence: The TCC-1416 electric lug and terminal crimper, combined with the TCK-178 solderless ring and lug terminal kit, provides reliable solutions for power distribution connections at panels, PDUs, and service entrance points.\u003cbr\u003e\u003cbr\u003e⦿\u003cstrong\u003e \u003c\/strong\u003eMeasure AC and DC circuits accurately: The ACM-1500DC Solar+ CAT III 1500V clamp meter is designed for electrical verification across generator feeds, solar arrays, and data center power infrastructure.\u003cbr\u003e\u003cbr\u003e⦿\u003cstrong\u003e \u003c\/strong\u003eStay organized and productive on large sites: The SOL-F1 rechargeable tactical flashlight provides dependable illumination for low-light work areas, while the BP-100 heavy-duty technician backpack keeps the complete tool kit organized and easily accessible across multi-building deployments.\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003e\u003c\/strong\u003e\u003cstrong\u003e\u003c\/strong\u003e\u003cstrong\u003e\u003c\/strong\u003e\u003cstrong\u003e\u003c\/strong\u003e\u003cstrong\u003e\u003c\/strong\u003e\u003cstrong\u003e\u003c\/strong\u003e\u003cstrong\u003e\u003c\/strong\u003e\u003cstrong\u003e\u003c\/strong\u003e\u003cstrong\u003e\u003c\/strong\u003e\u003cstrong\u003e\u003c\/strong\u003e\u003c\/p\u003e","brand":"Jonard Tools","offers":[{"title":"Default Title","offer_id":67614006706545,"sku":"TK-DC02","price":1189.95,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/1_35e20843-3ca1-4dc7-9140-ab0c565b2b52.jpg?v=1790848200","url":"https:\/\/nassaunationalcable.com\/products\/data-center-electrical-utility-kit-tk-dc02","provider":"NassauNationalCable","version":"1.0","type":"link"}