{"product_id":"750-mcm-3c-hvteck-copper-115-mil-trxlpe-ts-aia-5kv-133-or-8kv-100-il-orange-pvc-jacket-csa","title":"750 MCM 3C HVTECK Copper 115 mil TRXLPE TS AIA 5kV 133% or 8kV 100% IL Orange PVC Jacket CSA","description":"\u003cp\u003e[short] [pdf] \u003cembed src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/88_1.pdf?v=1756801685\"\u003e [\/pdf]\u003c\/embed\u003e\u003c\/p\u003e\n\u003ch2\u003e\u003cspan data-sheets-root=\"1\"\u003e750 MCM 3C HVTECK Copper 115 mil TRXLPE TS AIA 5kV 133% or 8kV 100% IL Orange PVC Jacket CSA\u003c\/span\u003e\u003c\/h2\u003e\n\u003ch3\u003eApplication\u003cstrong\u003e:\u003c\/strong\u003e\n\u003c\/h3\u003e\n\u003cp\u003eThe  5kV \/ 8kV HVTECK is a CSA armoured cable for industrial and commercial medium voltage applications. Rated FT4, -40°C, Hazardous Locations (HL). These cables are capable of operating continuously at the conductor temperature not in excess of 105°C for normal operation, 140°C for emergency overload, and 250°C for short circuit conditions. For installation in cable trays, duct banks, direct burial, troughs, continuous rigid cable supports and concrete encase able. Rated for 1000 lbs \/ FT maximum sidewall pressure. These cables feature sunlight and moisture resistance, exceptional corona resistance, resistance to most chemical soils and acids and are flame retardant 3 Conductor, 115 Mils Tree Retardant Cross Linked Polyethylene, 5kV 133% or 8kV 100% Insulation Level, Tape Shield, Polyvinyl Chloride (PVC) Inner Jacket, Aluminum Interlocked Armour (AIA), Polyvinyl Chloride (PVC) Jacket\u003c\/p\u003e\n\u003ch3\u003eAlso known as:\u003cbr\u003e\n\u003c\/h3\u003e\n\u003cdiv class=\"flex max-w-full flex-col grow\"\u003e\n\u003cdiv data-message-author-role=\"assistant\" data-message-id=\"8af04988-ab09-44ed-9c7d-0f0aa8dff7d4\" dir=\"auto\" class=\"min-h-8 text-message relative flex w-full flex-col items-end gap-2 text-start break-words whitespace-normal [.text-message+\u0026amp;]:mt-5\" data-message-model-slug=\"gpt-4o-mini\"\u003e\n\u003cdiv class=\"flex w-full flex-col gap-1 empty:hidden first:pt-[3px]\"\u003e\n\u003cdiv class=\"markdown prose dark:prose-invert w-full break-words light markdown-new-styling\"\u003e\n\u003cp data-end=\"171\" data-start=\"135\"\u003e750 MCM 3C HVTECK 3\/C 5kV\/8kV Armored Cable 750 MCM 3C HVTECK 3 Conductor Cable 5kV\/8kV Armored Power Cable Medium Voltage Armored Cable 750 MCM 3C CSA Approved Armored Cable TRXLPE Insulated Armored Cable AIA Armored Power Cable PVC Jacketed Armored Cable 3 Conductor 5kV\/8kV Armored Cable 750 MCM 3C HVTECK 5kV\/8kV Armored Cable\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003ch3\u003eConstruction:\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eConductor:\u003cbr\u003e\u003c\/strong\u003eClass B compressed stranded bare copper per ASTM B3 and ASTM B8\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003eConductor Shield:\u003cbr\u003e\u003c\/strong\u003eSemi-conducting cross-linked copolymer\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eInsulation\u003c\/strong\u003e:\u003cbr\u003e115 Mils Tree Retardant Cross Linked Polyethylene 133% insulation level\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003eInsulation Shield: \u003cbr\u003e\u003c\/strong\u003eStrippable semi-conducting cross-linked copolymer\u003cbr\u003e\u003cstrong\u003e\u003cbr\u003eCopper Tape Shield: \u003cbr\u003e\u003c\/strong\u003eHelically wrapped 5 mil copper tape with 25% overlap\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003eFiller:\u003cbr\u003e\u003c\/strong\u003eInterstices filled with non-hydroscoping\/non-wicking fillers\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003eGrounding Conductor:\u003cbr\u003e\u003c\/strong\u003eClass B compressed stranded bare copper ground per ASTM B3 and ASTM B8\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003eBinder:\u003cbr\u003e\u003c\/strong\u003ePolypropylene tape\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eInner Jacket:\u003cbr\u003e\u003c\/strong\u003ePVC inner jacket\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eArmour:\u003c\/strong\u003e\u003cbr\u003eAluminum Interlocked Armour (AIA)\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eOverall Jacket:\u003c\/strong\u003e\u003cbr\u003eOrange Polyvinyl Chloride (PVC) Jacket\u003cbr\u003e\u003c\/p\u003e\n\u003ch3\u003eStandards:\u003c\/h3\u003e\n\u003cp\u003e• ASTM B3 Soft or Annealed Copper Wire\u003cbr\u003e• ASTM B8 Concentric-Lay-Stranded Copper Conductors\u003cbr\u003e• CSA C22.2 No. 174 Cables in Hazardous Locations\u003cbr\u003e• CSA C22.2 No. 2556 \u0026amp; No. 0.3 Wire and Cable Test Methods\u003cbr\u003e• CSA C68.10 Shielded Power Cables for Commercial and Industrial Applications - 5 to 46 KV\u003cbr\u003e• CSA C68.3 Shielded \u0026amp; Concentric Neutral Power Cable - 5 to 46 kV\u003cbr\u003e• CSA LTGG [-40°C] - as per C68.10 - for Cold Bend and Impact rating\u003cbr\u003e• CSA HL - for Hazardous Locations rating\u003cbr\u003e• CSA SUN RES - for Sunlight Resistant rating\u003c\/p\u003e\n\u003ch3\u003eSpecification:\u003c\/h3\u003e\n\u003cp\u003e• \u003cstrong\u003eSize:\u003c\/strong\u003e 750 MCM\u003cbr\u003e\u003cstrong\u003e• Number of conductor: \u003c\/strong\u003e3\u003cbr\u003e• \u003cstrong\u003eNumber of Strands: \u003c\/strong\u003e61\u003cbr\u003e• \u003cstrong\u003eDiameter Over Conductor (inch):\u003c\/strong\u003e   0.968\u003cbr\u003e• \u003cstrong\u003eDiameter Over Insulation (inch):\u003c\/strong\u003e   1.254\u003cbr\u003e• \u003cstrong\u003eInsul. Thickness mil:\u003c\/strong\u003e 115\u003cbr\u003e• \u003cstrong\u003eDiameter Over Insulation Shield (inch): \u003c\/strong\u003e1.314\u003cbr\u003e\u003cstrong\u003e• Ground Size AWG: \u003c\/strong\u003e2\u003cbr\u003e• \u003cstrong\u003eInner Jacket Thickness (mil):\u003c\/strong\u003e  125  \u003cbr\u003e• \u003cstrong\u003eDiameter Over Armor (inch): \u003c\/strong\u003e 3.502\u003cbr\u003e• \u003cstrong\u003eOverall Jacket Thickness mil :  \u003c\/strong\u003e85\u003cbr\u003e• \u003cstrong\u003eApprox. OD inch :\u003c\/strong\u003e   3.672\u003cbr\u003e• \u003cstrong\u003eCopper Weight lb\/1000ft:\u003c\/strong\u003e  7539\u003cbr\u003e• \u003cstrong\u003eApprox. Weight (Lbs\/1000'Ft): \u003c\/strong\u003e 10935\u003cbr\u003e• \u003cstrong\u003eDC Resistance @ 25°C Ω \/1000ft:\u003c\/strong\u003e 0.014\u003cbr\u003e• \u003cstrong\u003eAC Resistance @ 90°Ω \/1000ft:\u003c\/strong\u003e 0.023\u003cbr\u003e• \u003cstrong\u003eAllowable Ampacity In Air 90°C Amp: \u003c\/strong\u003e 678\u003cbr\u003e• \u003cstrong\u003eAllowable Ampacity Directly Buried 90°C Amp:\u003c\/strong\u003e 668\u003c\/p\u003e\n\u003ctable style=\"width: 340px; height: 79.1904px;\"\u003e\n\u003ctbody\u003e\n\u003ctr style=\"height: 35.5966px;\"\u003e\n\u003ctd style=\"width: 325.114px; height: 35.5966px;\" colspan=\"2\"\u003e\n\u003cp style=\"text-align: center;\"\u003e\u003cstrong\u003eCompatible with Manufacturer\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.6023px;\"\u003e\n\u003ctd style=\"width: 160.597px;\"\u003e\u003cstrong\u003eSouthwire\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 164.517px;\"\u003e\u003cspan data-sheets-root=\"1\"\u003e671381\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e","brand":"Nassau National Cable","offers":[{"title":"Default Title","offer_id":55772486631793,"sku":"NNC671381","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/Untitled_design_3_1024x1024_2x_63189316-13fe-415a-ba03-caa8c3eb15ac.webp?v=1756971500","url":"https:\/\/nassaunationalcable.com\/products\/750-mcm-3c-hvteck-copper-115-mil-trxlpe-ts-aia-5kv-133-or-8kv-100-il-orange-pvc-jacket-csa","provider":"NassauNationalCable","version":"1.0","type":"link"}