{"product_id":"500-mcm-copper-sw-standard-wall-laminate-sheath-69-kv-xlpe-power-cable","title":"500 MCM Copper SW Standard Wall Laminate Sheath 69 kV XLPE Power Cable","description":"\u003cp\u003e[pdf] \u003cembed src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/High-Voltage-69kV-Power-Cable_3_1.pdf?v=1779865344\"\u003e [\/pdf]\u003c\/embed\u003e\u003c\/p\u003e\n\u003ch2\u003e\u003cspan data-sheets-root=\"1\"\u003e500 MCM Copper SW Standard Wall Laminate Sheath 69 kV XLPE Power Cable\u003c\/span\u003e\u003c\/h2\u003e\n\u003ch3\u003eApplications:\u003c\/h3\u003e\n\u003cdiv class=\"container-lg\"\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"col-md-12\"\u003e\n\u003cdiv id=\"product-tabs\"\u003e\n\u003cdiv class=\"tab-content p-3\"\u003e\n\u003cdiv id=\"pdp-application\" class=\"tab-pane fade show active\" role=\"tabpanel\"\u003e\n\u003cdiv class=\"tab-panel__content tab-panel__content--skinny\"\u003e\n\u003cp\u003ePredominantly used for underground transmission in conduit systems, suitable for use in wet or dry locations, direct burial, underground duct, and where exposed to sunlight. To be used at 69,000 volts or less and at conductor temperatures not to exceed 90°C for normal operation Compact Cu smooth condutor shield, super clean XLPE insulation, true triple extrusion and dry cured, firmly bonded insualtion shield, Cu moisture impervious sheath, PE jacket with extruded semi-conductive outer layer.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003ch3\u003eAlso Known As:\u003c\/h3\u003e\n\u003cp\u003e500 MCM 69kV Copper Conductor XLPE Insulated Power Cable High Voltage 69kV XLPE Copper Power Cable Corrugated Sheath 69kV Power Cable Copper Wire Shielded 69kV XLPE 500 MCM Cable Standard Wall XLPE High Voltage Cable 69kV Corrugated Metallic Sheath Power Cable Copper Shield Wire XLPE Transmission Cable High Voltage Underground 69kV 500 MCM Power Cable 69kV XLPE Insulated Copper Conductor Cable Corrugated Sheath Copper HV Power Cable Utility Grade 69kV XLPE Power Cable\u003c\/p\u003e\n\u003ch3\u003eCable Construction:\u003c\/h3\u003e\n\u003cp\u003e•  Concentric Stranded, Compact, or Segmental Copper Conductor\u003cbr\u003e•  Smooth Conductor Shield\u003cbr\u003e•  Super Clean XLPE Insulation\u003cbr\u003e•  True Triple Extrusion and Dry Cured\u003cbr\u003e•  Firmly Bonded Insulation Shield\u003cbr\u003e•  Copper Moisture Impervious Sheath\u003cbr\u003e•  Polyethylene Jacket with Extruded Semi-Conductive Outer Layer\u003cbr\u003e\u003c\/p\u003e\n\u003ch3\u003eCABLE DATA:\u003c\/h3\u003e\n\u003ch3\u003eVoltage Characteristics (kV)\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eMax Voltage Rating: \u003cspan style=\"font-size: 10.0pt; mso-bidi-font-size: 11.0pt; font-family: Consolas; mso-fareast-font-family: 'Trebuchet MS'; mso-hansi-font-family: 'Trebuchet MS'; mso-bidi-font-family: 'Trebuchet MS'; color: #1f1f1f; letter-spacing: -.2pt; mso-font-width: 95%; mso-ansi-language: EN-US; mso-fareast-language: EN-US; mso-bidi-language: AR-SA;\"\u003e72.5\u003c\/span\u003e\u003c\/strong\u003e\u003cbr\u003e\u003cstrong\u003eBIL Rating: \u003cspan style=\"font-size: 10.0pt; mso-bidi-font-size: 11.0pt; font-family: 'Trebuchet MS',sans-serif; mso-fareast-font-family: 'Trebuchet MS'; mso-bidi-font-family: 'Trebuchet MS'; color: #1f1f1f; letter-spacing: -.25pt; mso-ansi-language: EN-US; mso-fareast-language: EN-US; mso-bidi-language: AR-SA;\"\u003e350\u003c\/span\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003ch3\u003eTemperatures (°C)\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eNominal Conductor: \u003c\/strong\u003e90\u003cbr\u003e\u003cstrong\u003eMax. Emergency Conducto\u003c\/strong\u003er: 105\u003cbr\u003e\u003cstrong\u003eShort Circuit Conductor: \u003c\/strong\u003e250\u003cbr\u003e\u003cstrong\u003eMinimum Installation: \u003c\/strong\u003e-10\u003c\/p\u003e\n\u003ch3\u003eDesign Characteristics\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eDesign Standards: \u003c\/strong\u003eAEIC, IEC\u003cbr\u003e\u003cstrong\u003eFactory Test Voltages (@400 kV):\u003c\/strong\u003e \u003cspan style=\"font-size: 9.5pt; mso-bidi-font-size: 11.0pt; font-family: 'Trebuchet MS',sans-serif; mso-fareast-font-family: 'Trebuchet MS'; mso-bidi-font-family: 'Trebuchet MS'; color: #1f1f1f; mso-ansi-language: EN-US; mso-fareast-language: EN-US; mso-bidi-language: AR-SA;\"\u003e80\u003cspan style=\"letter-spacing: -.05pt;\"\u003e \u003c\/span\u003ekV\u003cspan style=\"letter-spacing: -.5pt;\"\u003e \u003c\/span\u003e\/\u003cspan style=\"letter-spacing: .9pt;\"\u003e \u003c\/span\u003e60\u003cspan style=\"letter-spacing: -.25pt;\"\u003e \u003c\/span\u003e\u003cspan style=\"letter-spacing: -.2pt;\"\u003emin\u003c\/span\u003e\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003eXLPE Loss Factor: \u003c\/strong\u003e0.0005\u003cbr\u003e\u003cstrong\u003eRelative Permittivity: \u003c\/strong\u003e2.3\u003cbr\u003e\u003c\/p\u003e\n\u003ch3\u003eSpecifications:\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eConductor Size:\u003c\/strong\u003e 500 MCM\u003cbr\u003e\u003cstrong\u003eConductor Dia. (inches):\u003c\/strong\u003e 0.Z4\u003cbr\u003e\u003cstrong\u003eInsulation Thickness (mils):\u003c\/strong\u003e  354\u003cbr\u003e\u003cstrong\u003eDiameter Over Insulation (inches):\u003c\/strong\u003e 1.54\u003cbr\u003e\u003cstrong\u003eOverall Jacket Diameter  (inches): \u003c\/strong\u003e2.10\u003cbr\u003e\u003cstrong\u003eMin. Bending Radius (install \/ perm.) (inches):\u003c\/strong\u003e 38\/26\u003cbr\u003e\u003cstrong\u003eCapacitance (pF\/ft):\u003c\/strong\u003e 65.87\u003cbr\u003e\u003cstrong\u003eCharging Current (A\/kft): \u003c\/strong\u003e0.99\u003cbr\u003e\u003cstrong\u003eCable Weight (lbs\/ft):\u003c\/strong\u003e 3.64\u003cbr\u003e\u003cstrong\u003eAmpacity @ 90°C; Single Circuit (Fig 1):\u003c\/strong\u003e 620  Amps\u003cbr\u003e\u003cstrong\u003ePower Rating:\u003c\/strong\u003e 74 MVA\u003cbr\u003e\u003cstrong\u003eAmpacity @ 90°C; Double Circuit (Fig 2):  \u003c\/strong\u003e520 Amps\u003cbr\u003e\u003cstrong\u003ePower Rating:\u003c\/strong\u003e 62 MVA\u003c\/p\u003e","brand":"Nassau National Cable","offers":[{"title":"Default Title","offer_id":63671879008625,"sku":"NNCSWG500","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/Untitled_design_-_2025-10-10T121832.852_a820d6a9-2565-4267-a5e4-904a2172d64c.png?v=1779877513","url":"https:\/\/nassaunationalcable.com\/products\/500-mcm-copper-sw-standard-wall-laminate-sheath-69-kv-xlpe-power-cable","provider":"NassauNationalCable","version":"1.0","type":"link"}