{"product_id":"500-mcm-3c-type-mv-105-copper-15kv-nlepr-insulation-133-il-aia-red-cpe-tp-jacket","title":"500 MCM 3C Type MV-105 Copper 15kV NLEPR Insulation 133% IL AIA Red CPE-TP Jacket","description":"\u003cp\u003e[pdf] \u003cembed type=\"application\/pdf\" height=\"\" width=\"\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/SOUTHWIRE_SPEC46461_1__removed.pdf?v=1755682829\"\u003e [\/pdf]\u003c\/embed\u003e\u003c\/p\u003e\n\u003ch2\u003e\u003cstrong\u003e\u003cspan data-sheets-root=\"1\"\u003e500 MCM 3C Type MV-105 Copper 15kV NLEPR Insulation 133% IL AIA Red CPE-TP Jacket\u003c\/span\u003e\u003c\/strong\u003e\u003c\/h2\u003e\n\u003ch3\u003e\u003cstrong\u003eApplication:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eThe 15KV cables are suited for use in wet and dry areas, conduits, ducts, troughs, trays, direct burial, and where superior electrical properties are desired. These cables are capable of operating continuously at the conductor temperature not in excess of 105°C for normal operation, 140°C for emergency overload, and 250°C for short circuit conditions. Rated at\u003cbr\u003e-35°C for cold bend when UL listed. Rated at -40°C for cold bend and cold impact and marked with \"LTGG\" when CSA listed or dual UL\/CSA listed. For uses in Class I and II, Division 2 hazardous locations per NEC Article 501 and 502.Rated for 1000 lbs.\/FT maximum sidewall pressure.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eAlso Known As:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e500 MCM 3C MV-105 Copper 15kV Cable, Three Conductor 15kV Cable, NLEPR Insulation 15kV Cable, 133% IL MV Cable, AIA Red CPE-TP Jacket, 500 MCM  3C Copper 15kV NLEPR Cable, CPE-TP Jacketed MV Cable, MV-105 15kV CPE-TP Cable, NLEPR Insulation Copper Cable, 500 MCM  3C 15kV Three Conductor MV-105 Cable.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eStandards:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e• ASTM B3 Soft or Annealed Copper Wire\u003cbr\u003e• ASTM B8 Concentric-Lay-Stranded Copper Conductors\u003cbr\u003e• ASTM B33 Standard Specification for Tin-Coated Soft or Annealed Copper Wire\u003cbr\u003e• UL 1072 Medium-Voltage Power Cables\u003cbr\u003e• UL 1685 Vertical-Tray Fire Propagation and Smoke Release Test\u003cbr\u003e• ICEA S-93-639 (NEMA WC 74) 5-46 KV Shielded Power Cable\u003cbr\u003e• AEIC CS-8 Specification for extruded dielectric shielded power cables rated for 5 through 46KV (Qualification Test Requirements)\u003cbr\u003e• Made in America: Compliant with both Buy American and Buy America Act (BAA) requirements per 49 U.S.C. § 5323(j) and the Federal Transit Administration Buy America requirements per 49 C.F.R. part 661.\u003cbr\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eConstruction:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003e• Conductor: \u003c\/strong\u003eClass B compressed stranded bare copper per ASTM B3 and ASTM B8 (Tinned Copper per ASTM B33 optional)\u003cstrong\u003e\u003cbr\u003e• Conductor Shield:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003eSemi-conducting cross-linked copolymer\u003cstrong\u003e\u003cbr\u003e• Insulation:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003e220 Mils No Lead Ethylene Propylene Rubber (NL-EPR) 133% Insulation Level,\u003cstrong\u003e\u003cbr\u003e• Insulation Shield:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003eStrippable semi-conducting cross-linked copolymer\u003cstrong\u003e\u003cbr\u003e• Copper Tape Shield:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003eHelically wrapped 5 mil copper tape with 25% overlap\u003cstrong\u003e\u003cbr\u003e• Grounding Conductor:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003eClass B compressed stranded bare copper ground per ASTM B3 and ASTM B8 (Tinned Copper per ASTM B33 optional)\u003cstrong\u003e\u003cbr\u003e• Filler:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003eWax paper filler\u003cstrong\u003e\u003cbr\u003e• Binder:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003ePolypropylene tape\u003cstrong\u003e\u003cbr\u003e• Armor:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003eAluminum Interlocked Armor (AIA)\u003cstrong\u003e\u003cbr\u003e• Overall Jacket:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003eBlack thermoplastic Chlorinated Polyethylene (CPE-TP) jacket\u003c\/p\u003e\n\u003ch4\u003e\u003cstrong\u003eSpecifications:\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cp\u003e\u003cstrong\u003e• Size:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003e500 MCM \u003cspan\u003e\u003cbr\u003e\u003cstrong\u003e• Number of Conductor:\u003c\/strong\u003e 3 + 1G\u003cbr\u003e\u003cstrong\u003e• Number of Strands:\u003c\/strong\u003e 37\u003cbr\u003e\u003cstrong\u003e• Diameter Over Conductor (inch): \u003c\/strong\u003e0.789\u003cbr\u003e\u003cstrong\u003e• Diameter Over Insulation (inch):\u003c\/strong\u003e 1.275\u003cbr\u003e\u003cstrong\u003e• Diameter Over Insulation Shield (inch): \u003c\/strong\u003e1.335\u003cbr\u003e\u003c\/span\u003e\u003cspan\u003e\u003cstrong\u003e• Ground No. x AWG:\u003c\/strong\u003e  1x1\u003cbr\u003e\u003cstrong\u003e• Diameter Over Armor\u003c\/strong\u003e \u003cstrong\u003e(inch):\u003c\/strong\u003e  3.255\u003cbr\u003e\u003cstrong\u003e• Jacket Thickness (mil):\u003c\/strong\u003e 90\u003cbr\u003e\u003cstrong\u003e• Approx. OD (In):\u003c\/strong\u003e 3.443\u003cbr\u003e\u003cstrong\u003e• Copper Weight lb\/1000ft:\u003c\/strong\u003e 5259\u003cbr\u003e\u003cstrong\u003e• Approx. Weight (Lbs\/1000'Ft):\u003c\/strong\u003e 8085\u003cbr\u003e\u003cstrong\u003e• Min Bending Radius (In):\u003c\/strong\u003e  24.1\u003cbr\u003e\u003cstrong\u003e• DC Resistance @ 25°C Ω \/1000ft:  \u003c\/strong\u003e0.022\u003cbr\u003e\u003cstrong\u003e• AC Resistance @ 90°Ω \/1000ft:\u003c\/strong\u003e   0.030\u003cbr\u003e\u003cstrong\u003e• Inductive Reactance @ 60HzΩ\/1000ft:\u003c\/strong\u003e  0.034\u003cbr\u003e\u003cstrong\u003e• Allowable Ampacity In Duct 90\/105°C Amp :\u003c\/strong\u003e  450\/485\u003cbr\u003e\u003cstrong\u003e• Allowable Ampacity In Air 90\/105°C Amp:\u003c\/strong\u003e 535\/600\u003cbr\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003ctable style=\"width: 340px; height: 79.1904px;\"\u003e\n\u003ctbody\u003e\n\u003ctr style=\"height: 35.5966px;\"\u003e\n\u003ctd colspan=\"2\" style=\"width: 325.114px; height: 35.5966px;\"\u003e\n\u003cp style=\"text-align: center;\"\u003e\u003cstrong\u003eCompatible with Manufacturer\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.6023px;\"\u003e\n\u003ctd style=\"width: 160.597px;\"\u003e\u003cstrong\u003eSouthwire\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 164.517px;\"\u003e\u003cspan data-sheets-root=\"1\"\u003e646907\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e","brand":"Nassau National Cable","offers":[{"title":"Default Title","offer_id":55744668434801,"sku":"NNC646907","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/1_2a44457c-0759-4aa2-b9ca-e6bb8a2497f8.png?v=1755769827","url":"https:\/\/nassaunationalcable.com\/products\/500-mcm-3c-type-mv-105-copper-15kv-nlepr-insulation-133-il-aia-red-cpe-tp-jacket","provider":"NassauNationalCable","version":"1.0","type":"link"}