{"product_id":"500-mcm-37-str-aluminum-primary-ud-cable-10-awg-full-neutral-epr-pvc-mv-90-100-345-mil-35-kv","title":"500 MCM 37 Str Aluminum Primary UD Cable 10 AWG Full Neutral EPR \/ PVC MV-90 100% 345 mil 35 kV","description":"\u003cp\u003e[pdf] \u003cembed src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/pud-05-epr-pvc_2__removed_1.pdf?v=1746525695\"\u003e [\/pdf]\u003c\/embed\u003e\u003c\/p\u003e\n\u003ch2\u003e\u003cstrong\u003e\u003cspan data-sheets-root=\"1\"\u003e500 MCM 37 Str Aluminum Primary UD Cable 10 AWG Full Neutral EPR \/ PVC MV-90 100% 345 mil 35 kV\u003c\/span\u003e\u003c\/strong\u003e\u003c\/h2\u003e\n\u003ch3\u003e\u003cstrong\u003eApplication:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e• Underground primary residential and commercial distribution circuits.\u003cbr\u003e• May be used in wet or dry locations, installed in underground ducts or direct burial.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eAlso Known As:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e500 MCM Aluminum MV-90 UD cable 15kV, EPR PVC concentric neutral cable 25kV, Primary UD cable 5kV to 46kV, 500 MCM Aluminum underground power cable MV-90, 15kV EPR PVC concentric UD cable, 500 MCM Medium voltage UD cable aluminum.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eStandards:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003e• ICEA S-94-649: \u003c\/strong\u003eStandard for Concentric Neutral Rated Cables 5 kV – 46 kV\u003cbr\u003e\u003cstrong\u003e• AEIC CS8:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eSpecifications for Extruded Dielectric, Shielded Power Cable, rated 5 kV – 46 kV\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eMaximum operating voltage:\u003c\/strong\u003e\u003cbr\u003e• 5 kV – 46 kV, 100 and 133% IL\u003cbr\u003e\u003cstrong\u003eMaximum conductor operation\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003e\u003cstrong\u003etemperatures:\u003c\/strong\u003e\u003cbr\u003eWet and dry locations\u003cbr\u003e• Normal: 105 °C\u003cbr\u003e• Emergency: 140 °C\u003cbr\u003e• Short Circuit: 250 °C\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eConstruction:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003e• Conductor:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003eHard drawn aluminum Class B compressed or unilay compressed stranding per ASTM B231. On request: strand filled. Sizes: 8 AWG – 1000 kcmil. On request, larger sizes.\u003cbr\u003e\u003cstrong\u003e• Conductor Shield:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003eSemi conducting cross-linked polyethylene (XLPE). On request: super clean and super smooth materials.\u003cbr\u003e\u003cstrong\u003e• Insulation:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003eThermoset ethylene propylene rubber (EPR). On request: amorphous EPR.\u003cbr\u003e\u003cstrong\u003e• Insulation Shield:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eSemi conducting cross-linked polyethylene (XLPE).\u003cbr\u003e\u003cstrong\u003e• Concentric Neutral:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003eSoft annealed solid copper wires per ASTM B3, helically applied and uniformly spaced. Full or 1\/3 Neutral. On request options: alternate neutral constructions, Water Swellable Powder (WSP), and ripcords.\u003cbr\u003e\u003cstrong\u003e• Binder Tape:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eA suitable polyester tape, as required.\u003cbr\u003e\u003cstrong\u003e• Jacket:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003eExtruded Overlying (Sleeve) Black polyvinyl chloride (PVC) sunlight resistant.\u003cbr\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eFeatures:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e• Low tension stripping compounds.\u003cbr\u003e• Sealed conductor passes the production water penetration tests per ICEA-T-31-610 at 15 psi for 60 minutes.\u003cbr\u003e• Strand Filled compound meets compatibility test requirements in accordance with ICEA-T-32-610.\u003cbr\u003e• True Triple extrusion system and closed handling raw materials system, to eliminate any contact with ambient, until extrusion of insulation and shields.\u003cbr\u003e• On request, can be UL Listed as MV105 for use in accordance with Article 328 of the NEC.\u003cbr\u003e• On request, two abration resistant ripcords placed longitudinally 180° appart for easy jacket removal.\u003c\/p\u003e\n\u003ch4\u003e\u003cstrong\u003eSpecifications:\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cp\u003e\u003cstrong\u003e• Size:\u003c\/strong\u003e\u003cspan\u003e 500 MCM\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Number of Strands:\u003c\/strong\u003e\u003cspan\u003e 37\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Nominal OD Over Insulation (In):\u003c\/strong\u003e\u003cspan\u003e 1.53\u003cbr\u003e\u003cstrong\u003e• Number of Wires:\u003c\/strong\u003e  29\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Full Neutral Size:\u003c\/strong\u003e\u003cspan\u003e 10 \u003c\/span\u003eAWG\u003cbr\u003e\u003cstrong\u003e• Jacket Thickness (mil): \u003c\/strong\u003e110\u003cbr\u003e\u003cstrong\u003e• Approximate Outside Diameter (In):\u003c\/strong\u003e\u003cspan\u003e  2.10\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Approximate Net Weight lb\/kft:\u003c\/strong\u003e\u003cspan\u003e  2786\u003c\/span\u003e\u003c\/p\u003e","brand":"Nassau National Cable","offers":[{"title":"Default Title","offer_id":55219154125169,"sku":"NNC5008EPR\/PVC","price":36.14,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/1_d30ec62c-eef3-432f-802f-b2956a486780.png?v=1763024795","url":"https:\/\/nassaunationalcable.com\/products\/500-mcm-37-str-aluminum-primary-ud-cable-10-awg-full-neutral-epr-pvc-mv-90-100-345-mil-35-kv","provider":"NassauNationalCable","version":"1.0","type":"link"}