{"product_id":"500-1-0-1-0-1-0-bergen-triplex-aluminum-conductor-underground-direct-burial-600v-urd-cable","title":"500' 1\/0-1\/0-1\/0 Bergen Triplex Aluminum Conductor Underground Direct Burial 600V URD Cable","description":"\u003cp\u003e[pdf] \u003cembed src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/AL_URD_db962859-f302-441c-91c4-10d874e463ce.pdf?v=1782134036\" width=\"\" height=\"\" type=\"application\/pdf\"\u003e [\/pdf]\u003c\/embed\u003e\u003c\/p\u003e\n\u003cp\u003e[short]\u003c\/p\u003e\n\u003ch2\u003e1\/0-1\/0-1\/0 Bergen Triplex Aluminum Conductor Underground Direct Burial 600V URD Cable\u003c\/h2\u003e\n\u003cp\u003e\u003cb\u003eAllowable Ampacity\u003c\/b\u003e\u003cspan style=\"font-weight: 400;\"\u003e for\u003c\/span\u003e\u003cspan style=\"font-weight: 400;\"\u003e 1\/0-1\/0-1\/0 Bergen Triplex Aluminum Conductor 600V URD Cable direct burial: 215 Amps\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cb\u003eAllowable Ampacity\u003c\/b\u003e\u003cspan style=\"font-weight: 400;\"\u003e for \u003c\/span\u003e\u003cspan style=\"font-weight: 400;\"\u003e1\/0-1\/0-1\/0 Bergen Triplex Aluminum Conductor 600V URD Cable in duct: 160 Amps\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cspan style=\"font-weight: 400;\"\u003eApplications:\u003c\/span\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cmeta charset=\"UTF-8\"\u003e\u003cspan\u003eThe Aluminum 600V URD is designed to serve in the secondary distribution circuits for power. In these secondary circuits, the electrical cable is installed in duct or direct burial applications. Due to its versatility, conductor strength, and insulation integrity, it works well for these outdoor applications. It is also used in wet and dry places since the electrical cable has a maximum operating temperature of 90\u003c\/span\u003e\u003cspan\u003e°\u003c\/span\u003e\u003cspan\u003eC. The triplex wire for sale is also designed to provide an option of pre-pulling into ducts.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cspan\u003eAlso Known As:\u003c\/span\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cspan\u003e1\/0-1\/0-1\/0 bergen aluminum urd cable, 1\/0-1\/0-1\/0 bergen urd direct burial cable, 1\/0-1\/0-1\/0 bergen three conductor cable, 1\/0-1\/0-1\/0 bergen tri plex wire, 1\/0-1\/0-1\/0 bergen triplex cable, 1\/0-1\/0-1\/0 bergen triplex aluminum underground wire, 1\/0-1\/0-1\/0 bergen 3 conductor power cable, 1\/0-1\/0-1\/0 bergen aluminum triplex, 1\/0-1\/0-1\/0 bergen underground triplex, 1\/0-1\/0-1\/0 bergen triplex underground cable, 1\/0-1\/0-1\/0 bergen triplex wire underground, 1\/0-1\/0-1\/0 bergen direct burial triplex, 1\/0-1\/0-1\/0 bergen triplex conductor, 1\/0-1\/0-1\/0 bergen direct burial electrical cable, 1\/0-1\/0-1\/0 bergen direct burial power cable, 1\/0-1\/0-1\/0 bergen aluminum direct burial cable.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cspan style=\"font-weight: 400;\"\u003eStandards:\u003c\/span\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli style=\"font-weight: 400;\"\u003e\n\u003cp\u003e\u003cspan style=\"font-weight: 400;\"\u003eASTM B-230\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli style=\"font-weight: 400;\"\u003e\n\u003cp\u003e\u003cspan style=\"font-weight: 400;\"\u003eASTM B-231\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli style=\"font-weight: 400;\"\u003e\n\u003cp\u003e\u003cspan style=\"font-weight: 400;\"\u003eASTM B-609\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli style=\"font-weight: 400;\"\u003e\n\u003cp\u003e\u003cspan style=\"font-weight: 400;\"\u003eASTM B-901\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli style=\"font-weight: 400;\"\u003e\n\u003cp\u003e\u003cspan style=\"font-weight: 400;\"\u003eICEA S-105-692\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli style=\"font-weight: 400;\"\u003e\n\u003cp\u003e\u003cspan style=\"font-weight: 400;\"\u003eJ-C- 30B Federal Specification\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli style=\"font-weight: 400;\"\u003e\n\u003cp\u003e\u003cspan style=\"font-weight: 400;\"\u003eRUS accepted\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cspan style=\"font-weight: 400;\"\u003eConstruction\u003c\/span\u003e\u003c\/h3\u003e\n\u003ch4\u003e\u003cspan style=\"font-weight: 400;\"\u003eConductors:\u003c\/span\u003e\u003c\/h4\u003e\n\u003cp\u003e\u003cspan style=\"font-weight: 400;\"\u003eAluminum conductors used for this cable are designed in either concentric strand or in compressed series. The advantage with a compressed conductor is the reduced bulkiness. Compressed conductors are also stronger and tougher; the stranded conductors are highly flexible and tend to have lower electrical resistance. Stranded conductors therefore reduce power loss and are also easier to use in applications where flexibility is vital. Aluminum 600 V URD cable \u003c\/span\u003e\u003cspan style=\"font-weight: 400;\"\u003ehas three aluminum conductors.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch4\u003e\u003cspan style=\"font-weight: 400;\"\u003eInsulation:\u003c\/span\u003e\u003c\/h4\u003e\n\u003cp\u003e\u003cspan style=\"font-weight: 400;\"\u003eVersatile insulation system made of cross linked black polyethylene material helps to secure the cable conductors. This insulation is water tight, repulsive to corrosive substances, resistant to oil, heat and flame. Cross linking a polyethylene helps to achieve an excellent strength that makes the material suitable for covering this cable used in harsh conditions like direct burial installation.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cspan style=\"font-weight: 400;\"\u003eSpecifications:\u003c\/span\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cul\u003e\n\u003cli style=\"font-weight: 400;\"\u003e\n\u003cp\u003e\u003cb\u003eSize AWG\u003c\/b\u003e\u003cspan style=\"font-weight: 400;\"\u003e: \u003c\/span\u003e\u003cspan style=\"font-weight: 400;\"\u003e1\/0\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli style=\"font-weight: 400;\"\u003e\n\u003cp\u003e\u003cb\u003eStranding\u003c\/b\u003e\u003cspan style=\"font-weight: 400;\"\u003e: 19\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli style=\"font-weight: 400;\"\u003e\n\u003cp\u003e\u003cb\u003eInsulation Thickness (mils)\u003c\/b\u003e\u003cspan style=\"font-weight: 400;\"\u003e: 80\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli style=\"font-weight: 400;\"\u003e\n\u003cp\u003e\u003cb\u003eNeutral Size AWG\u003c\/b\u003e\u003cspan style=\"font-weight: 400;\"\u003e: 1\/0\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli style=\"font-weight: 400;\"\u003e\n\u003cp\u003e\u003cb\u003eSingle Phase Conductor Inches\u003c\/b\u003e\u003cspan style=\"font-weight: 400;\"\u003e: 0.522\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli style=\"font-weight: 400;\"\u003e\n\u003cp\u003e\u003cb\u003eO.D. Inches\u003c\/b\u003e\u003cspan style=\"font-weight: 400;\"\u003e:  1.133\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli style=\"font-weight: 400;\"\u003e\n\u003cp\u003e\u003cspan style=\"font-weight: 400;\"\u003e\u003c\/span\u003e\u003cstrong\u003eWeight lbs.\/1000ft\u003c\/strong\u003e\u003cspan style=\"font-weight: 400;\"\u003e: 465 lbs\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli style=\"font-weight: 400;\"\u003e\n\u003cp\u003e\u003cb\u003e\u003c\/b\u003e\u003cb\u003eAmpacity: \u003c\/b\u003e\u003cb\u003e\u003ci\u003eDirect burial\u003c\/i\u003e\u003c\/b\u003e\u003cb\u003e: \u003c\/b\u003e\u003cspan style=\"font-weight: 400;\"\u003e215 Amps\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli style=\"font-weight: 400;\"\u003e\n\u003cp\u003e\u003cb\u003eAmpacity: \u003c\/b\u003e\u003cb\u003e\u003ci\u003eIn duct\u003c\/i\u003e\u003c\/b\u003e\u003cb\u003e: \u003c\/b\u003e\u003cspan style=\"font-weight: 400;\"\u003e160 Amps\u003c\/span\u003e \u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/ul\u003e\n\u003cp\u003e[\/short]\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eApplication:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eAluminum 600V URD cable is designed for use in secondary distribution circuits, where installed in duct or direct burial applications. Maximum operating temperature is not to exceed 90°C in wet and dry locations. Voltage rating is 600 volts. As an option, this cable can provided pre-pulled into duct. \u003cbr\u003e\u003cbr\u003e\u003cstrong\u003eConductors:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eAluminum 600V URD cable has a concentric strand or compressed 1350-H19 series aluminum conductor. Conductors are cabled together, with surface printing for identification. The neutral conductor has a yellow stripe. \u003cbr\u003e\u003cbr\u003e\u003cstrong\u003eInsulation:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eAluminum 600V URD cable has a black cross linked polyethylene (XLP) insulation.\u003cstrong\u003e \u003c\/strong\u003e\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003eStandards:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eASTM B-230 \u003c\/li\u003e\n\u003cli\u003eASTM B-231 \u003c\/li\u003e\n\u003cli\u003eASTM B-609 \u003c\/li\u003e\n\u003cli\u003eASTM B-901 \u003c\/li\u003e\n\u003cli\u003eICEA S-105-692 \u003c\/li\u003e\n\u003cli\u003eFederal Specification J-C – 30B\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Nassau Stock","offers":[{"title":"Default Title","offer_id":40328501788826,"sku":"NNC1915X10","price":1110.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/Bergen_Hun_Roc_Mon_1.png?v=1762458448","url":"https:\/\/nassaunationalcable.com\/products\/500-1-0-1-0-1-0-bergen-triplex-aluminum-conductor-underground-direct-burial-600v-urd-cable","provider":"NassauNationalCable","version":"1.0","type":"link"}