{"product_id":"4-awg-aluminum-xlp-use-2-rhh-rhw-2-direct-burial-building-wire","title":"4 AWG Aluminum XLP USE-2 RHH\/RHW-2 Direct Burial Building Wire","description":"\u003cp\u003e[pdf] \u003cembed type=\"application\/pdf\" height=\"\" width=\"\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/AL_XLP.pdf?v=1724417087\"\u003e [\/pdf]\u003c\/embed\u003e\u003c\/p\u003e\n\u003ch2\u003e4 AWG Aluminum XLP USE-2 RHH\/RHW-2 Direct Burial Building Wire\u003c\/h2\u003e\n\u003cp data-end=\"368\" data-start=\"282\"\u003e\u003cstrong data-end=\"366\" data-start=\"282\"\u003eAllowable Ampacity for 4 AWG Aluminum XLP USE-2 RHH\/RHW-2 Direct Burial Building Wire: 65 Amps\u003c\/strong\u003e\u003c\/p\u003e\n\u003ch3 data-end=\"392\" data-start=\"370\"\u003e\u003cstrong data-end=\"390\" data-start=\"375\"\u003eDescription\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp data-end=\"967\" data-start=\"393\"\u003eThis cable is a versatile power distribution cable with multiple ratings—RHH, RHW-2, XLP, and USE-2—designed for underground and raceway installations. The RHH rating indicates heat resistance for dry locations, while RHW-2 ensures water resistance and a 90°C maximum operating temperature in both wet and dry conditions. The XLP (cross-linked polyethylene) insulation enhances durability, abrasion resistance, and electrical performance. The USE-2 rating makes it suitable for service entrance installations below ground and direct burial.\u003c\/p\u003e\n\u003cp data-end=\"1338\" data-start=\"969\"\u003eUSE-2 cables are commonly used for power distribution, service entrance below ground, and direct burial, as well as in raceways. This electrical cable is approved under the National Electrical Code (NEC), except for use in cable trays. It supports a voltage rating of 600V and operates at a maximum temperature of 90°C in wet and dry environments.\u003c\/p\u003e\n\u003ch3 data-end=\"1384\" data-start=\"1340\"\u003e\u003cstrong data-end=\"1382\" data-start=\"1344\"\u003eAmpacity Ratings (Per NEC 310.16):\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul data-end=\"1482\" data-start=\"1385\"\u003e\n\u003cli data-end=\"1425\" data-start=\"1385\"\u003e\n\u003cstrong data-end=\"1409\" data-start=\"1387\"\u003eIn Free Air (90°C)\u003c\/strong\u003e → \u003cstrong data-end=\"1423\" data-start=\"1412\"\u003e85 Amps\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli data-end=\"1482\" data-start=\"1426\"\u003e\n\u003cstrong data-end=\"1466\" data-start=\"1428\"\u003eIn Direct Burial or Raceway (90°C)\u003c\/strong\u003e → \u003cstrong data-end=\"1480\" data-start=\"1469\"\u003e65 Amps\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 data-end=\"1530\" data-start=\"1484\"\u003e\u003cstrong data-end=\"1528\" data-start=\"1488\"\u003eCommon Applications for 4 AWG Cable:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul data-end=\"1959\" data-start=\"1531\"\u003e\n\u003cli data-end=\"1646\" data-start=\"1531\"\u003e\n\u003cstrong data-end=\"1589\" data-start=\"1533\"\u003ePrimary and secondary underground power distribution\u003c\/strong\u003e for larger residential and light commercial buildings.\u003c\/li\u003e\n\u003cli data-end=\"1726\" data-start=\"1647\"\u003e\n\u003cstrong data-end=\"1676\" data-start=\"1649\"\u003eService entrance wiring\u003c\/strong\u003e for single-phase and three-phase power systems.\u003c\/li\u003e\n\u003cli data-end=\"1794\" data-start=\"1727\"\u003e\n\u003cstrong data-end=\"1748\" data-start=\"1729\"\u003eFeeder circuits\u003c\/strong\u003e for panelboards and distribution equipment.\u003c\/li\u003e\n\u003cli data-end=\"1864\" data-start=\"1795\"\u003e\n\u003cstrong data-end=\"1828\" data-start=\"1797\"\u003eDirect burial installations\u003c\/strong\u003e for medium-duty electrical loads.\u003c\/li\u003e\n\u003cli data-end=\"1959\" data-start=\"1865\"\u003e\n\u003cstrong data-end=\"1912\" data-start=\"1867\"\u003eIndustrial and agricultural installations\u003c\/strong\u003e requiring cost-effective underground wiring.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eAlso Known As:\u003c\/h3\u003e\n\u003cp\u003e\u003cspan style=\"font-weight: 400;\"\u003e4 aluminum rhh wire, 4 aluminum rhw cable, 4 aluminum bury cable, direct burial electrical cable, direct burial power cable, direct burial service entrance cable.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003eStandards:\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cspan style=\"font-weight: 400;\"\u003eUL 44\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan style=\"font-weight: 400;\"\u003eUL 854\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan style=\"font-weight: 400;\"\u003eNEMA WC 70\/ICEA S-95-658\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan style=\"font-weight: 400;\"\u003eRequirements of the National Electrical Code\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan style=\"font-weight: 400;\"\u003eASTM B800, B801, B836\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan style=\"font-weight: 400;\"\u003eSunlight resistant\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan style=\"font-weight: 400;\"\u003eOil Resistant PRI\/PRII\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan style=\"font-weight: 400;\"\u003eGas and Oil Res GRI\/GRII\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan style=\"font-weight: 400;\"\u003eRUS ACCEPTED\u003c\/span\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eConstruction\u003c\/h3\u003e\n\u003ch4\u003e\u003cspan style=\"font-weight: 400;\"\u003eConductors:\u003c\/span\u003e\u003c\/h4\u003e\n\u003cp\u003e\u003cspan style=\"font-weight: 400;\"\u003eCompact bare 8000 series aluminum, with Class B stranding per ASTM. \u003c\/span\u003e\u003c\/p\u003e\n\u003ch4\u003e\u003cspan style=\"font-weight: 400;\"\u003eInsulation:\u003c\/span\u003e\u003c\/h4\u003e\n\u003cp\u003eAbrasion, heat and moisture resistant cross-linked polyethylene insulation (XLP)\u003c\/p\u003e\n\u003ch3\u003eSpecifications:\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli style=\"font-weight: 400;\"\u003e\n\u003cp\u003e\u003cb\u003eGauge\u003c\/b\u003e\u003cspan style=\"font-weight: 400;\"\u003e: \u003c\/span\u003e\u003cspan style=\"font-weight: 400;\"\u003e4\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli style=\"font-weight: 400;\"\u003e\n\u003cp\u003e\u003cb\u003eStranding\u003c\/b\u003e\u003cspan style=\"font-weight: 400;\"\u003e: 7\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli style=\"font-weight: 400;\"\u003e\n\u003cp\u003e\u003cb\u003eConductor Diameter Inches\u003c\/b\u003e\u003cspan style=\"font-weight: 400;\"\u003e: 0.213\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli style=\"font-weight: 400;\"\u003e\n\u003cp\u003e\u003cb\u003eInsulation Thickness Inches\u003c\/b\u003e\u003cspan style=\"font-weight: 400;\"\u003e: 0.080\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli style=\"font-weight: 400;\"\u003e\n\u003cp\u003e\u003cb\u003eO.D. Inches\u003c\/b\u003e\u003cspan style=\"font-weight: 400;\"\u003e: 0.370\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli style=\"font-weight: 400;\"\u003e\n\u003cp\u003e\u003cb\u003eNew Weight lb\/1000FT\u003c\/b\u003e\u003cspan style=\"font-weight: 400;\"\u003e: 236 lbs\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli style=\"font-weight: 400;\"\u003e\n\u003cp\u003e\u003cb\u003eAmpacity \u003c\/b\u003e\u003cb\u003eat 30°C\u003c\/b\u003e\u003cspan style=\"font-weight: 400;\"\u003e: 65 Amps\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ctable style=\"width: 382px; height: 151px;\"\u003e\n\u003ctbody\u003e\n\u003ctr style=\"height: 21px;\"\u003e\n\u003ctd colspan=\"2\" style=\"width: 372px; height: 21px;\"\u003e\n\u003cp style=\"text-align: center;\"\u003e\u003cstrong\u003eCompatible with Manufacturer\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 119px;\"\u003e\n\u003ctd style=\"width: 216.469px; height: 119px;\"\u003e\u003cstrong\u003eHouston item :\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 244.531px; height: 119px;\"\u003e\n\u003cspan\u003e\u003cstrong\u003eBlack : \u003c\/strong\u003eHW003A00401\u003cbr\u003e\u003c\/span\u003e\u003cspan\u003e\u003cstrong\u003eBlack : \u003c\/strong\u003e4-01XLPUSEBLACKAL\u003c\/span\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 35px;\"\u003e\n\u003ctd style=\"width: 184.188px; height: 35px;\"\u003e\u003cstrong\u003ePriority Wire \u0026amp; Cable :\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 181.812px; height: 35px;\"\u003e\n\u003cstrong\u003eBlack :\u003c\/strong\u003e 4-01XL-USE-2-ALUM\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 63px;\"\u003e\n\u003ctd style=\"width: 216.469px; height: 63px;\"\u003e\u003cstrong\u003eSouthwire :\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 244.531px; height: 63px;\"\u003e\n\u003cstrong\u003eBlack :\u003c\/strong\u003e 27280701\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e[\/short]\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eApplication\u003c\/strong\u003e:\u003c\/p\u003e\n\u003cp\u003eUSE-2 cables are primarily used for power distribution, in raceways in accordance with National Electrical Code, except that the cable is not rated for use in cable tray. USE-2 is approved for direct burial and for service entrance below ground. USE-2 cables may be used in wet or dry locations, with ambient temperatures not exceeding 90°C. Voltage rating for USE-2 cable is 600V. \u003cbr\u003e\u003cbr\u003e\u003cstrong\u003eConductors\u003c\/strong\u003e:\u003c\/p\u003e\n\u003cp\u003eUSE-2 conductor is a soft drawn bare 8000 series aluminum, with Class B stranding per ASTM \u003cbr\u003e\u003cbr\u003e\u003cstrong\u003eInsulation\u003c\/strong\u003e:\u003c\/p\u003e\n\u003cp\u003eUSE-2 has abrasion, heat and moisture resistant cross-linked polyethylene insulation XLPE \u003cbr\u003e\u003cbr\u003e\u003cstrong\u003eStandards\u003c\/strong\u003e:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eUSE-2 meets or exceeds the following standards \u003c\/li\u003e\n\u003cli\u003eUL 44 \u003c\/li\u003e\n\u003cli\u003eRequirements of the National Electrical Code \u003c\/li\u003e\n\u003cli\u003eASTM standards B 800, B 801 \u003c\/li\u003e\n\u003cli\u003eSunlight resistant \u003c\/li\u003e\n\u003cli\u003eRUS ACCEPTED\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Nassau National Cable","offers":[{"title":"Black","offer_id":42418608898202,"sku":"NNC1273X","price":0.71,"currency_code":"USD","in_stock":true},{"title":"Green","offer_id":42418608930970,"sku":"NNC1273X-2","price":0.71,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/IMA_XLP_BLK_d2dfaa04-2c10-4fed-a5d8-790d136d6d93.png?v=1780986161","url":"https:\/\/nassaunationalcable.com\/products\/4-awg-aluminum-xlp-use-2-rhh-rhw-2-direct-burial-building-wire","provider":"NassauNationalCable","version":"1.0","type":"link"}