{"product_id":"4-4-4-vassar-triplex-aluminum-conductor-underground-direct-burial-600v-urd-cable","title":"4-4-4 Vassar Triplex Aluminum Conductor Underground Direct Burial 600V URD Cable","description":"\u003cp\u003e[pdf] \u003cembed type=\"application\/pdf\" height=\"\" width=\"\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/AL_URD.pdf?v=1698446562\"\u003e [\/pdf]\u003c\/embed\u003e\u003c\/p\u003e\n\u003cp\u003e[short]\u003c\/p\u003e\n\u003ch2\u003e4-4-4 Vassar Triplex Aluminum Conductor Underground Direct Burial 600V URD Cable\u003c\/h2\u003e\n\u003cp\u003e\u003cb\u003eAllowable Ampacity\u003c\/b\u003e\u003cspan style=\"font-weight: 400;\"\u003e for\u003c\/span\u003e\u003cspan style=\"font-weight: 400;\"\u003e 4-4-4 Vassar Triplex Aluminum Conductor 600V URD Cable direct burial: 125 Amps\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cb\u003eAllowable Ampacity\u003c\/b\u003e\u003cspan style=\"font-weight: 400;\"\u003e for \u003c\/span\u003e\u003cspan style=\"font-weight: 400;\"\u003e4-4-4 Vassar Triplex Aluminum Conductor 600V URD Cable in duct: 90 Amps\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cspan style=\"font-weight: 400;\"\u003eApplications:\u003c\/span\u003e\u003c\/h3\u003e\n\u003cp\u003eThe 4-4-4 Vassar Triplex Aluminum URD Cable is designed for single-phase secondary power distribution in underground electrical systems. It is 600V-rated and suitable for direct burial or installation in ducts. With aluminum conductors and XLPE insulation, this cable is moisture-resistant, heat-resistant, and durable for outdoor use.\u003c\/p\u003e\n\u003cp\u003eWith a maximum operating temperature of 90°C, it performs reliably in both wet and dry environments. The triplex configuration, consisting of two 4 AWG phase conductors and a 4 AWG neutral, makes it ideal for single-phase service drops from transformers to buildings.\u003c\/p\u003e\n\u003ch3\u003e\u003cspan\u003eAlso Known As:\u003c\/span\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cspan\u003e4-4-4 vassar aluminum urd cable, 4-4-4 vassar urd direct burial cable, 4-4-4 vassar three conductor cable, 4-4-4 vassar tri plex wire, 4-4-4 vassar triplex cable, 4-4-4 vassar triplex aluminum underground wire, 4-4-4 vassar 3 conductor power cable, 4-4-4 vassar aluminum triplex, 4-4-4 vassar underground triplex, 4-4-4 vassar triplex underground cable, 4-4-4 vassar triplex wire underground, 4-4-4 vassar direct burial triplex, 4-4-4 vassar triplex conductor, 4-4-4 vassar direct burial electrical cable, 4-4-4 vassar direct burial power cable, 4-4-4 vassar aluminum direct burial cable, \u003cmeta charset=\"utf-8\"\u003e4-4-4 aluminum wire\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eSpecific Use Cases of 4-4-4 URD\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eDistributes single-phase power to service meters in residential and rural areas.\u003c\/li\u003e\n\u003cli\u003eSupplies underground power to small commercial buildings and municipal facilities.\u003c\/li\u003e\n\u003cli\u003eProvides electricity to single-family homes and small multi-unit residences.\u003c\/li\u003e\n\u003cli\u003eUsed in street lighting and municipal distribution.\u003c\/li\u003e\n\u003cli\u003eConnects residential solar and battery storage systems.\u003c\/li\u003e\n\u003cli\u003eSupports temporary power for construction, events, and backups.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cspan style=\"font-weight: 400;\"\u003eStandards:\u003c\/span\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli style=\"font-weight: 400;\"\u003e\n\u003cp\u003e\u003cspan style=\"font-weight: 400;\"\u003eASTM B-230\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli style=\"font-weight: 400;\"\u003e\n\u003cp\u003e\u003cspan style=\"font-weight: 400;\"\u003eASTM B-231\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli style=\"font-weight: 400;\"\u003e\n\u003cp\u003e\u003cspan style=\"font-weight: 400;\"\u003eASTM B-609\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli style=\"font-weight: 400;\"\u003e\n\u003cp\u003e\u003cspan style=\"font-weight: 400;\"\u003eASTM B-901\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli style=\"font-weight: 400;\"\u003e\n\u003cp\u003e\u003cspan style=\"font-weight: 400;\"\u003eICEA S-105-692\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli style=\"font-weight: 400;\"\u003e\n\u003cp\u003e\u003cspan style=\"font-weight: 400;\"\u003eJ-C- 30B Federal Specification\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli style=\"font-weight: 400;\"\u003e\n\u003cp\u003e\u003cspan style=\"font-weight: 400;\"\u003eRUS accepted\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cspan style=\"font-weight: 400;\"\u003eConstruction\u003c\/span\u003e\u003c\/h3\u003e\n\u003ch4\u003e\u003cspan style=\"font-weight: 400;\"\u003eConductors:\u003c\/span\u003e\u003c\/h4\u003e\n\u003cp\u003e\u003cspan style=\"font-weight: 400;\"\u003eAluminum conductors used for this cable are designed in either concentric strand or in compressed series. The advantage with a compressed conductor is the reduced bulkiness. Compressed conductors are also stronger and tougher; the stranded conductors are highly flexible and tend to have lower electrical resistance. Stranded conductors therefore reduce power loss and are also easier to use in applications where flexibility is vital. Aluminum 600 V URD cable \u003c\/span\u003e\u003cspan style=\"font-weight: 400;\"\u003ehas three aluminum conductors.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch4\u003e\u003cspan style=\"font-weight: 400;\"\u003eInsulation:\u003c\/span\u003e\u003c\/h4\u003e\n\u003cp\u003e\u003cspan style=\"font-weight: 400;\"\u003eVersatile insulation system made of cross linked black polyethylene material helps to secure the cable conductors. This insulation is water tight, repulsive to corrosive substances, resistant to oil, heat and flame. Cross linking a polyethylene helps to achieve an excellent strength that makes the material suitable for covering this cable used in harsh conditions like direct burial installation.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cspan style=\"font-weight: 400;\"\u003eSpecifications:\u003c\/span\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cul\u003e\n\u003cli style=\"font-weight: 400;\"\u003e\n\u003cp\u003e\u003cb\u003eSize AWG\u003c\/b\u003e\u003cspan style=\"font-weight: 400;\"\u003e: \u003c\/span\u003e\u003cspan style=\"font-weight: 400;\"\u003e4\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli style=\"font-weight: 400;\"\u003e\n\u003cp\u003e\u003cb\u003eStranding\u003c\/b\u003e\u003cspan style=\"font-weight: 400;\"\u003e: 7\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli style=\"font-weight: 400;\"\u003e\n\u003cp\u003e\u003cb\u003eInsulation Thickness (mils)\u003c\/b\u003e\u003cspan style=\"font-weight: 400;\"\u003e: 60\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli style=\"font-weight: 400;\"\u003e\n\u003cp\u003e\u003cb\u003eNeutral Size AWG\u003c\/b\u003e\u003cspan style=\"font-weight: 400;\"\u003e: 4\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli style=\"font-weight: 400;\"\u003e\n\u003cp\u003e\u003cb\u003eSingle Phase Conductor Inches\u003c\/b\u003e\u003cspan style=\"font-weight: 400;\"\u003e: 0.345\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli style=\"font-weight: 400;\"\u003e\n\u003cp\u003e\u003cb\u003eO.D. Inches\u003c\/b\u003e\u003cspan style=\"font-weight: 400;\"\u003e:  0.754\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli style=\"font-weight: 400;\"\u003e\n\u003cp\u003e\u003cspan style=\"font-weight: 400;\"\u003e\u003c\/span\u003e\u003cstrong\u003eWeight lbs.\/1000ft\u003c\/strong\u003e\u003cspan style=\"font-weight: 400;\"\u003e: 200 lbs\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli style=\"font-weight: 400;\"\u003e\n\u003cp\u003e\u003cb\u003e\u003c\/b\u003e\u003cb\u003eAmpacity: \u003c\/b\u003e\u003cb\u003e\u003ci\u003eDirect burial\u003c\/i\u003e\u003c\/b\u003e\u003cb\u003e: \u003c\/b\u003e\u003cspan style=\"font-weight: 400;\"\u003e125 Amps\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli style=\"font-weight: 400;\"\u003e\n\u003cp\u003e\u003cb\u003eAmpacity: \u003c\/b\u003e\u003cb\u003e\u003ci\u003eIn duct\u003c\/i\u003e\u003c\/b\u003e\u003cb\u003e: \u003c\/b\u003e\u003cspan style=\"font-weight: 400;\"\u003e90 Amps\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/ul\u003e\n\u003cp\u003e[\/short]\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eApplication:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eAluminum 600V URD cable is designed for use in secondary distribution circuits, where installed in duct or direct burial applications. Maximum operating temperature is not to exceed 90°C in wet and dry locations. Voltage rating is 600 volts. As an option, this cable can provided pre-pulled into duct. \u003cbr\u003e\u003cbr\u003e\u003cstrong\u003eConductors:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eAluminum 600V URD cable has a concentric strand or compressed 1350-H19 series aluminum conductor. Conductors are cabled together, with surface printing for identification. The neutral conductor has a yellow stripe. \u003cbr\u003e\u003cbr\u003e\u003cstrong\u003eInsulation:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eAluminum 600V URD cable has a black cross linked polyethylene (XLP) insulation.\u003cstrong\u003e \u003c\/strong\u003e\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003eStandards:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eASTM B-230 \u003c\/li\u003e\n\u003cli\u003eASTM B-231 \u003c\/li\u003e\n\u003cli\u003eASTM B-609 \u003c\/li\u003e\n\u003cli\u003eASTM B-901 \u003c\/li\u003e\n\u003cli\u003eICEA S-105-692 \u003c\/li\u003e\n\u003cli\u003eFederal Specification J-C – 30B\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Nassau Stock","offers":[{"title":"Default Title","offer_id":27475861209188,"sku":"NNC1911X","price":1.13,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/Ersk_Vas_Ram_1.png?v=1762458445","url":"https:\/\/nassaunationalcable.com\/products\/4-4-4-vassar-triplex-aluminum-conductor-underground-direct-burial-600v-urd-cable","provider":"NassauNationalCable","version":"1.0","type":"link"}