{"product_id":"350-mcm-37-str-copper-primary-ud-cable-12-awg-1-3-neutral-epr-133-220-mil-15-kv","title":"350 MCM 37 Str Copper Primary UD Cable 12 AWG 1\/3 Neutral EPR 133% 220 mil 15 kV","description":"\u003cp\u003e[pdf] \u003cembed src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/pud-08-epr-ins_OCR_1.pdf?v=1748852301\"\u003e [\/pdf]\u003c\/embed\u003e\u003c\/p\u003e\n\u003ch2\u003e\u003cstrong\u003e\u003cspan data-sheets-root=\"1\"\u003e350 MCM 37 Str Copper Primary UD Cable 12 AWG 1\/3 Neutral EPR 133% 220 mil 15 kV\u003c\/span\u003e\u003c\/strong\u003e\u003c\/h2\u003e\n\u003ch3\u003e\u003cstrong\u003eApplication:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cspan data-sheets-root=\"1\"\u003e• Underground primary residential and commercial distribution circuits.\u003cbr\u003e• May be used in wet or dry locations, installed in underground ducts or direct burial. \u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eAlso Known As:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e350 MCM Copper EPR cable, Concentric neutral EPR cable, 350 MCM Primary UD cable copper 15kV, EPR insulated concentric neutral cable, 15kV primary underground cable, 10kV copper EPR concentric cable, 350 MCM Medium voltage EPR concentric cable.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eStandards:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e•\u003cstrong\u003e\u003cspan\u003e \u003c\/span\u003eICEA S-94-649: \u003c\/strong\u003eStandard for Concentric Neutral Rated Cables 546 kV.\u003cbr\u003e•\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eAEICCS8:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eSpecifications for Extruded Dielectric, Shielded Power Cable, rated 5 —46 kV. \u003cbr\u003e\u003cbr\u003e\u003cstrong\u003eMaximum operating voltage:\u003c\/strong\u003e\u003cbr\u003e• 5KV —46kV, 100 and 133% IL\u003cbr\u003e\u003cstrong\u003eMaximum conductor operation temperatures:\u003c\/strong\u003e\u003cbr\u003eWet and dry locations\u003cbr\u003e•  Normal: 105°C\u003cbr\u003e•  Emergency: 140°C\u003cbr\u003e• Short Circuit: 250 °C \u003cbr\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eConstruction:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003e• Conductor: \u003c\/strong\u003eSoft annealed uncoated copper Class B compressed or unilay compressed per ASTM B8. On request, strand filled. Sizes: 8 AWG — 1000 kemil. On request, larger sizes.\u003cbr\u003e\u003cstrong\u003e• Conductor Shield:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eSemi conducting cross-linked polyethylene (XLPE). On request, super-clean and super-smooth materials. \u003cbr\u003e\u003cstrong\u003e• Insulation:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003eThermoset ethylene propylene rubber (EPR). On request, amorphous EPR.\u003cbr\u003e•\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eInsulation Shield:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003eSemi conducting cross-linked polyethylene (XLPE).\u003cbr\u003e•\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eConcentric Neutral:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eTinned coated soft annealed solid copper wires per ASTM B3 and B33, helically applied and uniformly spaced. Full or 1\/3 Neutral. \u003cbr\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eFeatures:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e• Low tension stripping compounds.\u003cbr\u003e• Sealed conductor passes the production water penetration tests per ICEA-T-31-610 at 15 psi for 60 minutes.\u003cbr\u003e• True Triple extrusion system and closed handling raw materials system, to eliminate any contact with ambient, until extrusion of insulation and shields. \u003c\/p\u003e\n\u003ch4\u003e\u003cstrong\u003eSpecifications:\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cp\u003e\u003cstrong\u003e• Size:\u003c\/strong\u003e\u003cspan\u003e 350 MCM\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Number of Strands:\u003c\/strong\u003e\u003cspan\u003e 37\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Nominal OD Over Insulation (In):\u003c\/strong\u003e\u003cspan\u003e 1.16\u003cbr\u003e\u003cstrong\u003e• Number of Wires:\u003c\/strong\u003e 18\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• 1\/3 Neutral Size:\u003c\/strong\u003e\u003cspan\u003e 12 \u003c\/span\u003eAWG\u003cbr\u003e\u003cstrong\u003e• Approximate Outside Diameter (In):\u003c\/strong\u003e\u003cspan\u003e 1.41\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Approximate Net Weight lb\/kft:\u003c\/strong\u003e\u003cspan\u003e 1932\u003c\/span\u003e\u003c\/p\u003e","brand":"Nassau National Cable","offers":[{"title":"Default Title","offer_id":55259722154353,"sku":"NNC35037UDEPR","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/116_fe6e766c-22e2-45cb-9b17-d359cf910e9c.png?v=1763025461","url":"https:\/\/nassaunationalcable.com\/products\/350-mcm-37-str-copper-primary-ud-cable-12-awg-1-3-neutral-epr-133-220-mil-15-kv","provider":"NassauNationalCable","version":"1.0","type":"link"}