{"product_id":"30a-208v-mi-basic-power-distribution-unit-black-p36d08m","title":"30A 208V MI Basic Power Distribution Unit Black P36D08M","description":"\u003ch2\u003e\u003cstrong style=\"font-size: 0.875rem;\"\u003eAbout:\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cp\u003e• (30) C13 Outlets These outlets are suitable for devices that require up to 10 amps of power, including computers, monitors, and networking devices.\u003cbr\u003e• (6) C19 Outlets These larger outlets are designed for higher-power devices, such as servers, switches, or other equipment that can draw up to 16 amps.\u003cbr\u003e• The PDU can handle a total of 30 amps of current, providing reliable power for various IT and industrial equipment without overloading.\u003cbr\u003e• The 208V three-phase configuration ensures balanced and efficient power distribution, commonly used in commercial and industrial environments to support multiple high-power devices.\u003cbr\u003e• The NEMA L15-30P plug is typically used in three-phase systems and provides reliable power input for the PDU.\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eAlso Known As:\u003cbr\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp data-pm-slice=\"1 1 []\"\u003ePower Distribution Strip, Non-Intelligent PDU, Standard PDU, Rack-Mount Power Strip, Entry-Level PDU, Basic PDU, Power Distribution Unit, PDU, MI Basic Power Distribution Unit.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eSpecification:\u003c\/strong\u003e\u003cbr\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003ctable style=\"height: 433.923px; width: 69.1606%;\" width=\"100%\"\u003e\n\u003ctbody\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 54.8325%; height: 19.5938px; text-align: center;\"\u003e\u003cstrong\u003eProduct Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 44.6493%; text-align: center; height: 19.5938px;\" class=\"pl-2 border-all border-block\"\u003e\u003cspan\u003e\u003cspan\u003ePDU\u003c\/span\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 54.8325%; text-align: center; height: 19.5938px;\"\u003e\u003cstrong\u003e\u003cspan\u003eMount Orientation\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd class=\"pl-2 border-all border-block\" style=\"width: 44.6493%; text-align: center; height: 19.5938px;\"\u003e\u003cspan\u003eVertical\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 54.8325%; text-align: center; height: 19.5938px;\"\u003e\u003cstrong\u003e\u003cspan\u003eRack PDU Type\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 44.6493%; text-align: center; height: 19.5938px;\"\u003e\u003cspan\u003e\u003cspan\u003eMonitored Input\u003c\/span\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 54.8325%; text-align: center; height: 19.5938px;\" class=\"pl-2 border-all table-column-width border-block pdt-td-border-top\"\u003e\u003cstrong\u003eIncludes\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 44.6493%; text-align: center; height: 19.5938px;\" class=\"pl-2 border-all border-block\"\u003e\u003cspan\u003eMounting Hardware\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 54.8325%; text-align: center; height: 19.5938px;\"\u003e\u003cstrong\u003e\u003cspan\u003ePlug Type\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd class=\"pl-2 border-all border-block\" style=\"width: 44.6493%; text-align: center; height: 19.5938px;\"\u003e\u003cspan\u003eNEMA L15-30P\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 54.8325%; text-align: center; height: 19.5938px;\"\u003e\u003cstrong\u003e\u003cspan\u003ePhase\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 44.6493%; text-align: center; height: 19.5938px;\"\u003e\u003cspan\u003e3-Phase\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd class=\"pl-2 border-all table-column-width border-block pdt-td-border-top\" style=\"width: 54.8325%; text-align: center; height: 19.5938px;\"\u003e\u003cstrong\u003eInput Cord Length (ft.)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd class=\"pl-2 border-all border-block\" style=\"width: 44.6493%; text-align: center; height: 19.5938px;\"\u003e\u003cspan\u003e3\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 54.8325%; text-align: center; height: 19.5938px;\"\u003e\u003cstrong\u003e\u003cspan\u003eInput Cord Length (m)\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 44.6493%; text-align: center; height: 19.5938px;\"\u003e\u003cspan\u003e10\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 21.1875px;\"\u003e\n\u003ctd style=\"width: 54.8325%; text-align: center; height: 21.1875px;\"\u003e\u003cstrong\u003e\u003cspan\u003eOutput Receptacles\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 44.6493%; text-align: center; height: 21.1875px;\"\u003e\u003cspan\u003e(30)C13, (6)C19\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 54.8325%; text-align: center; height: 19.5938px;\"\u003e\u003cstrong\u003e\u003cspan\u003eNumber of Circuit Breakers\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 44.6493%; text-align: center; height: 19.5938px;\"\u003e\u003cspan\u003e\u003cspan\u003e3\u003c\/span\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 54.8325%; text-align: center; height: 19.5938px;\"\u003e\u003cstrong\u003e\u003cspan\u003eInput Voltage (V)\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 44.6493%; text-align: center; height: 19.5938px;\"\u003e\u003cspan\u003e\u003cspan\u003e208\u003c\/span\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 54.8325%; text-align: center; height: 19.5938px;\"\u003e\u003cstrong\u003e\u003cspan\u003eInput Amperage (A)\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 44.6493%; text-align: center; height: 19.5938px;\" class=\"pl-2 border-all border-block\"\u003e\u003cspan\u003e30\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 22.5px;\"\u003e\n\u003ctd style=\"width: 54.8325%; height: 22.5px; text-align: center;\"\u003e\u003cstrong\u003e\u003cspan\u003eFrequency Compatibility (Hz)\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd class=\"pl-2 border-all border-block\" style=\"width: 44.6493%; text-align: center; height: 22.5px;\"\u003e\u003cspan\u003e\u003cspan\u003e50\/60\u003c\/span\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 54.8325%; text-align: center;\"\u003e\u003cstrong\u003e\u003cspan\u003eNetwork Compatibility\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 44.6493%; text-align: center;\"\u003e\u003cspan\u003e\u003cspan\u003e10 Mbps, 100 Mbps (Fast Ethernet), 1 Gbps (Gigabit)\u003c\/span\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 54.8325%; height: 19.5938px; text-align: center;\"\u003e\u003cstrong\u003e\u003cspan\u003e\u003cspan\u003eMaterial\u003c\/span\u003e\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd class=\"pl-2 border-all border-block\" style=\"width: 44.6493%; text-align: center; height: 19.5938px;\"\u003e\u003cspan\u003eMetal\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 54.8325%; text-align: center; height: 19.5938px;\"\u003e\u003cstrong\u003e\u003cspan\u003e\u003cspan\u003eOverall Height (In.)\u003c\/span\u003e\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 44.6493%; text-align: center; height: 19.5938px;\" class=\"pl-2 border-all border-block\"\u003e\u003cspan\u003e69\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 25.5938px;\"\u003e\n\u003ctd style=\"width: 54.8325%; text-align: center; height: 25.5938px;\"\u003e\u003cstrong\u003e\u003cspan\u003e\u003cspan\u003eOverall Height (mm)\u003c\/span\u003e\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 44.6493%; text-align: center; height: 25.5938px;\" class=\"pl-2 border-all border-block\"\u003e\u003cspan\u003e\u003cspan\u003e1750\u003c\/span\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 54.8325%; text-align: center; height: 19.5938px;\"\u003e\u003cstrong\u003e\u003cspan\u003e\u003cspan\u003eOverall Width (In.)\u003c\/span\u003e\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 44.6493%; text-align: center; height: 19.5938px;\" class=\"pl-2 border-all border-block\"\u003e\u003cspan\u003e2\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 54.8325%; text-align: center; height: 19.5938px;\"\u003e\u003cstrong\u003e\u003cspan\u003e\u003cspan\u003eOverall Width (mm)\u003c\/span\u003e\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 44.6493%; text-align: center; height: 19.5938px;\" class=\"pl-2 border-all border-block\"\u003e\u003cspan\u003e\u003cspan\u003e52\u003c\/span\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 22.5938px;\"\u003e\n\u003ctd style=\"width: 54.8325%; text-align: center; height: 22.5938px;\"\u003e\u003cstrong\u003e\u003cspan\u003e\u003cspan\u003eNumber of Rack Units\u003c\/span\u003e\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 44.6493%; text-align: center; height: 22.5938px;\" class=\"pl-2 border-all border-block\"\u003e\u003cspan\u003e\u003cspan\u003e40\u003c\/span\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 54.8325%; text-align: center; height: 19.5938px;\"\u003e\u003cstrong\u003e\u003cspan\u003e\u003cspan\u003eColor\u003c\/span\u003e\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 44.6493%; text-align: center; height: 19.5938px;\" class=\"pl-2 border-all border-block\"\u003e\u003cspan\u003e\u003cspan\u003eBlack\u003c\/span\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 28.5469px;\"\u003e\n\u003ctd style=\"width: 54.8325%; text-align: center; height: 28.5469px;\"\u003e\u003cstrong\u003eUPC\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 44.6493%; text-align: center; height: 28.5469px;\"\u003e\u003cspan\u003e613056318052\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cspan\u003eFront Panel Display:\u003cbr\u003e\u003cbr\u003e\u003c\/span\u003e\u003c\/strong\u003eUse display to set IP address, update firmware, quick configure, rotate display, balance loads across phases, view alarms, read current, voltage, power and energy on the device.\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003eNetwork Monitoring Port:\u003cbr\u003e\u003cbr\u003e\u003c\/strong\u003eGigabit network port reduces labor by auto negotiating with data center level network switches.\u003cstrong\u003e\u003cbr\u003e\u003cbr\u003eFeatures:\u003c\/strong\u003e\u003cbr\u003e\u003cbr\u003e• The intelligent PDUs feature an enhanced designed web interface which detects the type of device that you are on and automatically adjusts the screen for an optimal experience\u003cbr\u003e• Meets demands of densely packed IT equipment in rack or cabinet space\u003cbr\u003e• Optimal form factor enables efficient rack space utilization\u003cbr\u003e• Easily identify phase to outlet banks to aid in fault isolation or load balancing\u003cbr\u003e\u003cbr\u003e\u003c\/p\u003e","brand":"Panduit","offers":[{"title":"Default Title","offer_id":52104549269873,"sku":"P36D08M","price":1929.29,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/Untitleddesign-2025-01-28T145044.786.jpg?v=1763021668","url":"https:\/\/nassaunationalcable.com\/products\/30a-208v-mi-basic-power-distribution-unit-black-p36d08m","provider":"NassauNationalCable","version":"1.0","type":"link"}