{"product_id":"3-0-awg-3c-type-mv-105-copper-15kv-nlepr-insulation-133-il-aia-red-cpe-tp-jacket","title":"3\/0 AWG 3C Type MV-105 Copper 15kV NLEPR Insulation 133% IL AIA Red CPE-TP Jacket","description":"\u003cp\u003e[pdf] \u003cembed src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/SOUTHWIRE_SPEC46461_1__removed.pdf?v=1755682829\" width=\"\" height=\"\" type=\"application\/pdf\"\u003e [\/pdf]\u003c\/embed\u003e\u003c\/p\u003e\n\u003ch2\u003e\u003cstrong\u003e\u003cspan data-sheets-root=\"1\"\u003e3\/0 AWG 3C Type MV-105 Copper 15kV NLEPR Insulation 133% IL AIA Red CPE-TP Jacket\u003c\/span\u003e\u003c\/strong\u003e\u003c\/h2\u003e\n\u003ch3\u003e\u003cstrong\u003eApplication:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eThe 15KV cables are suited for use in wet and dry areas, conduits, ducts, troughs, trays, direct burial, and where superior electrical properties are desired. These cables are capable of operating continuously at the conductor temperature not in excess of 105°C for normal operation, 140°C for emergency overload, and 250°C for short circuit conditions. Rated at\u003cbr\u003e-35°C for cold bend when UL listed. Rated at -40°C for cold bend and cold impact and marked with \"LTGG\" when CSA listed or dual UL\/CSA listed. For uses in Class I and II, Division 2 hazardous locations per NEC Article 501 and 502.Rated for 1000 lbs.\/FT maximum sidewall pressure.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eAlso Known As:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e3\/0 AWG 3C MV-105 Copper 15kV Cable, Three Conductor 15kV Cable, NLEPR Insulation 15kV Cable, 133% IL MV Cable, AIA Red CPE-TP Jacket, 3\/0 AWG 3C Copper 15kV NLEPR Cable, CPE-TP Jacketed MV Cable, MV-105 15kV CPE-TP Cable, NLEPR Insulation Copper Cable, 3\/0 AWG 3C 15kV Three Conductor MV-105 Cable.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eStandards:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e• ASTM B3 Soft or Annealed Copper Wire\u003cbr\u003e• ASTM B8 Concentric-Lay-Stranded Copper Conductors\u003cbr\u003e• ASTM B33 Standard Specification for Tin-Coated Soft or Annealed Copper Wire\u003cbr\u003e• UL 1072 Medium-Voltage Power Cables\u003cbr\u003e• UL 1685 Vertical-Tray Fire Propagation and Smoke Release Test\u003cbr\u003e• ICEA S-93-639 (NEMA WC 74) 5-46 KV Shielded Power Cable\u003cbr\u003e• AEIC CS-8 Specification for extruded dielectric shielded power cables rated for 5 through 46KV (Qualification Test Requirements)\u003cbr\u003e• Made in America: Compliant with both Buy American and Buy America Act (BAA) requirements per 49 U.S.C. § 5323(j) and the Federal Transit Administration Buy America requirements per 49 C.F.R. part 661.\u003cbr\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eConstruction:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003e• Conductor: \u003c\/strong\u003eClass B compressed stranded bare copper per ASTM B3 and ASTM B8 (Tinned Copper per ASTM B33 optional)\u003cstrong\u003e\u003cbr\u003e• Conductor Shield:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003eSemi-conducting cross-linked copolymer\u003cstrong\u003e\u003cbr\u003e• Insulation:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003e220 Mils No Lead Ethylene Propylene Rubber (NL-EPR) 133% Insulation Level,\u003cstrong\u003e\u003cbr\u003e• Insulation Shield:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003eStrippable semi-conducting cross-linked copolymer\u003cstrong\u003e\u003cbr\u003e• Copper Tape Shield:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003eHelically wrapped 5 mil copper tape with 25% overlap\u003cstrong\u003e\u003cbr\u003e• Grounding Conductor:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003eClass B compressed stranded bare copper ground per ASTM B3 and ASTM B8 (Tinned Copper per ASTM B33 optional)\u003cstrong\u003e\u003cbr\u003e• Filler:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003eWax paper filler\u003cstrong\u003e\u003cbr\u003e• Binder:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003ePolypropylene tape\u003cstrong\u003e\u003cbr\u003e• Armor:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003eAluminum Interlocked Armor (AIA)\u003cstrong\u003e\u003cbr\u003e• Overall Jacket:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003eBlack thermoplastic Chlorinated Polyethylene (CPE-TP) jacket\u003c\/p\u003e\n\u003ch4\u003e\u003cstrong\u003eSpecifications:\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cp\u003e\u003cstrong\u003e• Size:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003e3\/0 AWG\u003cspan\u003e\u003cbr\u003e\u003cstrong\u003e• Number of Conductor:\u003c\/strong\u003e 3 + 1G\u003cbr\u003e\u003cstrong\u003e• Number of Strands:\u003c\/strong\u003e 19\u003cbr\u003e\u003cstrong\u003e• Diameter Over Conductor (inch): \u003c\/strong\u003e 0.456\u003cbr\u003e\u003cstrong\u003e• Diameter Over Insulation (inch):\u003c\/strong\u003e  0.934\u003cbr\u003e\u003cstrong\u003e• Diameter Over Insulation Shield (inch): \u003c\/strong\u003e0.994\u003cbr\u003e\u003c\/span\u003e\u003cspan\u003e\u003cstrong\u003e• Ground No. x AWG:\u003c\/strong\u003e  1x3\u003cbr\u003e\u003cstrong\u003e• Diameter Over Armor\u003c\/strong\u003e \u003cstrong\u003e(inch):\u003c\/strong\u003e  2.512\u003cbr\u003e\u003cstrong\u003e• Jacket Thickness (mil):\u003c\/strong\u003e 75\u003cbr\u003e\u003cstrong\u003e• Approx. OD (In):\u003c\/strong\u003e  2.662\u003cbr\u003e\u003cstrong\u003e• Copper Weight lb\/1000ft:\u003c\/strong\u003e 1790\u003cbr\u003e\u003cstrong\u003e• Approx. Weight (Lbs\/1000'Ft):\u003c\/strong\u003e   3913\u003cbr\u003e\u003cstrong\u003e• Min Bending Radius (In):\u003c\/strong\u003e  18.6\u003cbr\u003e\u003cstrong\u003e• DC Resistance @ 25°C Ω \/1000ft: \u003c\/strong\u003e 0.064\u003cbr\u003e\u003cstrong\u003e• AC Resistance @ 90°Ω \/1000ft:\u003c\/strong\u003e  0.081\u003cbr\u003e\u003cstrong\u003e• Inductive Reactance @ 60HzΩ\/1000ft:\u003c\/strong\u003e  0.040\u003cbr\u003e\u003cstrong\u003e• Allowable Ampacity In Duct 90\/105°C Amp :\u003c\/strong\u003e  250\/270\u003cbr\u003e\u003cstrong\u003e• Allowable Ampacity In Air 90\/105°C Amp: \u003c\/strong\u003e285\/315\u003cbr\u003e\u003c\/span\u003e\u003c\/p\u003e","brand":"Nassau National Cable","offers":[{"title":"Default Title","offer_id":55744610074993,"sku":"NNC1186","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/1_cc58a44c-3872-4b75-9bcf-79d45d6334b3.png?v=1755769569","url":"https:\/\/nassaunationalcable.com\/products\/3-0-awg-3c-type-mv-105-copper-15kv-nlepr-insulation-133-il-aia-red-cpe-tp-jacket","provider":"NassauNationalCable","version":"1.0","type":"link"}