{"product_id":"250-mcm-3c-type-mv-105-copper-5-8kv-nlepr-insulation-133-100-il-aia-yellow-cpe-tp-jacket","title":"250 MCM 3C Type MV -105 Copper 5\/8kV NLEPR Insulation 133\/100% IL AIA Yellow CPE-TP Jacket","description":"\u003cp\u003e[short] [pdf] \u003cembed src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/978726_3.pdf?v=1755845754\"\u003e [\/pdf]\u003c\/embed\u003e\u003c\/p\u003e\n\u003ch2\u003e\u003cspan data-sheets-root=\"1\"\u003e250 MCM 3C Type MV -105 Copper 5\/8kV NLEPR Insulation 133\/100% IL AIA Yellow CPE-TP Jacket\u003c\/span\u003e\u003c\/h2\u003e\n\u003ch3\u003eApplication\u003cstrong\u003e:\u003c\/strong\u003e\n\u003c\/h3\u003e\n\u003cp\u003eThe 5KV cables are suited for use in wet and dry areas, conduits, ducts, troughs, trays, direct burial, and where superior electrical properties are desired. These cables are capable of operating continuously at the conductor temperature not in excess of 105°C for normal operation, 140°C for emergency overload, and 250°C for short circuit conditions. Rated at -25°C for cold bend. For uses in Class I and II, Division 2 hazardous locations per NEC Article 501 and 502.Rated for 1000 lbs.\/FT maximum sidewall pressure Type MV-105 Three Conductor Copper, 115 Mils No Lead Ethylene Propylene Rubber (NL-EPR) 133% Insulation Level, Tape Shield, Aluminum Interlocked Armor (AIA), Thermoplastic Chlorinated Polyethylene (CPE-TP) Jacket. Silicone Free\u003c\/p\u003e\n\u003ch3\u003eAlso known as:\u003cbr\u003e\n\u003c\/h3\u003e\n\u003cp data-end=\"202\" data-start=\"164\"\u003e250 MCM 3C MV-105 Three Conductor Power Cable Medium Voltage 5\/8kV Copper Cable Three Conductor 5\/8kV Copper Power Cable 250 MCM 3C MV Copper Cable with NLEPR Insulation Medium Voltage Cable with CPE-TP Jacket 133% Insulation Level Copper Power Cable AIA Insulated 5\/8kV 250 MCM 3C MV Cable Yellow CPE-TP Jacketed MV Copper Cable 105°C Rated 5\/8kV Copper Cable Triple-Conductor 5\/8kV Power Cable\u003c\/p\u003e\n\u003ch3\u003eConstruction:\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eConductor:\u003cbr\u003e\u003c\/strong\u003eClass B compressed stranded bare copper per ASTM B3 and ASTM B8 (Tinned Copper per ASTM B33optional)\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003eConductor Shield:\u003cbr\u003e\u003c\/strong\u003eSemi-conducting cross-linked copolymer\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eInsulation\u003c\/strong\u003e:\u003cbr\u003e115 Mils No Lead Ethylene Propylene Rubber (NL-EPR) 133% Insulation Level, \u003cbr\u003e\u003cbr\u003e\u003cstrong\u003eInsulation Shield: \u003cbr\u003e\u003c\/strong\u003eStrippable semi-conducting cross-linked copolymer\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003eCopper Tape Shield:\u003cbr\u003e\u003c\/strong\u003eHelically wrapped 5 mil copper tape with 25% overlap\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003eGrounding Conductor:\u003cbr\u003e\u003c\/strong\u003eClass B compressed stranded bare copper ground per ASTM B3 and ASTM B8 (Tinned Copper per ASTM B33 optional)\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eFiller\u003c\/strong\u003e:\u003cbr\u003eWax paper filler\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eBinder\u003c\/strong\u003e:\u003cbr\u003e Polypropylene tape\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eArmor\u003c\/strong\u003e:\u003cbr\u003eAluminum Interlocked Armor (AIA)\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eOverall Jacket:\u003c\/strong\u003e\u003cbr\u003eThermoplastic Chlorinated Polyethylene (CPE-TP) \u003cbr\u003e\u003c\/p\u003e\n\u003ch3\u003eStandards:\u003c\/h3\u003e\n\u003cp\u003e• ASTM B3 Soft or Annealed Copper Wire\u003cbr\u003e• ASTM B8 Concentric-Lay-Stranded Copper Conductors\u003cbr\u003e• ASTM B33 Standard Specification for Tin-Coated Soft or Annealed Copper Wire\u003cbr\u003e• UL 1072 Medium-Voltage Power Cables\u003cbr\u003e• UL 1685 Vertical-Tray Fire Propagation and Smoke Release Test\u003cbr\u003e• ICEA S-93-639 (NEMA WC 74) 5-46 KV Shielded Power Cable\u003cbr\u003e• ICEA S-97-682 Standard for Shielded Utility Cable Rated for 5 - 46kV\u003cbr\u003e• AEIC CS-8 Specification for extruded dielectric shielded power cables rated for 5 through 46KV (Qualification Test\u003c\/p\u003e\n\u003ch3\u003eSpecification:\u003cbr\u003e\n\u003c\/h3\u003e\n\u003cp\u003e• \u003cstrong\u003eSize:\u003c\/strong\u003e  250 MCM\u003cbr\u003e•\u003cstrong\u003e Number of Conductor: \u003c\/strong\u003e3 + 1G\u003cbr\u003e• \u003cstrong\u003eNumber of Strands:\u003c\/strong\u003e   37\u003cbr\u003e• \u003cstrong\u003eDiameter Over Conductor (inch): \u003c\/strong\u003e  0.558\u003cbr\u003e• \u003cstrong\u003eDiameter Over Insulation (inch):\u003c\/strong\u003e    0.818\u003cbr\u003e•\u003cstrong\u003e Diameter Over Insulation Shield:\u003c\/strong\u003e 0.878\u003cbr\u003e•\u003cstrong\u003e Ground No. x AWG: \u003c\/strong\u003e 1x2\u003cbr\u003e• \u003cstrong\u003eDiameter Over Armor (inch): \u003c\/strong\u003e  2.278\u003cbr\u003e• \u003cstrong\u003eJacket Thickness (mil):  \u003c\/strong\u003e  80\u003cbr\u003e• \u003cstrong\u003eApprox. OD (In):\u003c\/strong\u003e   2.442\u003cbr\u003e• \u003cstrong\u003eCopper Weight lb\/1000ft:\u003c\/strong\u003e 2761\u003cbr\u003e• \u003cstrong\u003eApprox. Weight (Lbs\/1000'Ft): \u003c\/strong\u003e 4330\u003cbr\u003e• \u003cstrong\u003eDC Resistance @ 25°C Ω \/1000ft: \u003c\/strong\u003e 0.043\u003cbr\u003e• \u003cstrong\u003eAC Resistance @ 90°Ω \/1000ft:\u003c\/strong\u003e    0.056\u003cbr\u003e• \u003cstrong\u003eAllowable Ampacity In Duct 90\/105°C Amp\u003c\/strong\u003e :   290\/315\u003cbr\u003e• \u003cstrong\u003eAllowable Ampacity In Air 90\/105°C Amp: \u003c\/strong\u003e 320\/355\u003cbr\u003e\u003c\/p\u003e\n\u003ctable style=\"width: 340px; height: 79.1904px;\"\u003e\n\u003ctbody\u003e\n\u003ctr style=\"height: 35.5966px;\"\u003e\n\u003ctd style=\"width: 325.114px; height: 35.5966px;\" colspan=\"2\"\u003e\n\u003cp style=\"text-align: center;\"\u003e\u003cstrong\u003eCompatible with Manufacturer\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.6023px;\"\u003e\n\u003ctd style=\"width: 160.597px;\"\u003e\u003cstrong\u003eSouthwire\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 164.517px;\"\u003e\u003cspan data-sheets-root=\"1\"\u003e577531\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e","brand":"Nassau National Cable","offers":[{"title":"Default Title","offer_id":55747966108017,"sku":"NNC577531","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/500_4.png?v=1755844500","url":"https:\/\/nassaunationalcable.com\/products\/250-mcm-3c-type-mv-105-copper-5-8kv-nlepr-insulation-133-100-il-aia-yellow-cpe-tp-jacket","provider":"NassauNationalCable","version":"1.0","type":"link"}