{"product_id":"250-mcm-3c-type-mv-105-copper-35kv-nlepr-insulation-133-il-armor-x-orange-pvc-jacket","title":"250 MCM 3C Type MV-105 Copper 35kV NLEPR Insulation 133% IL ARMOR-X Orange PVC Jacket","description":"\u003cp\u003e[pdf] \u003cembed src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/SPEC46854_1_1.pdf?v=1789457882\"\u003e [\/pdf]\u003c\/embed\u003e\u003c\/p\u003e\n\u003ch2\u003e\u003cspan\u003e250 MCM 3C Type MV-105 Copper 35kV NLEPR Insulation 133% IL ARMOR-X Orange PVC Jacket\u003c\/span\u003e\u003c\/h2\u003e\n\u003ch3\u003e\u003cspan\u003eApplication:\u003c\/span\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cspan\u003eThe 35KV ARMOR-X are armored cables for use in wet and dry areas, conduits, ducts, troughs, trays, direct burial, and where superior electrical properties are desired. These cables are capable of operating continuously at the conductor temperature not in excess of 105°C for normal operation, 140°C for emergency overload, 250°C for short circuit conditions, and -50°C for cold bend. For uses in Class I, II, and III, Division 1 and 2 hazardous locations per NEC Article 501, 502, and 503. Type MV-105 Three Conductor Copper, 420 Mils No Lead Ethylene Propylene Rubber (NL-EPR) 133% Insulation Level, Tape Shield, Continuous Corrugated Welded Armor - ARMOR-X, Polyvinyl Chloride (PVC) Jacket. Silicone Free.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cspan\u003eAlso known as:\u003c\/span\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cspan\u003e250 MCM 3C 35kV Medium Voltage Cable, 250 MCM 3C 35kV MV-105 Cable, 250 MCM 3C 3-Conductor 35kV Copper Cable, 250 MCM 3C 35kV Armored Power Cable, 250 MCM 3C  ARMOR-X Cable, 250 MCM 3C 133% Insulation Level Cable, 250-3C NL-EPR Insulated Cable,  250-3C Copper Tape Shielded Cable, 250-3C  Continuous Corrugated Welded Armor Cable,  250-3C CCW Armored Cable, 250-3C 35kV Direct Burial Cable, 250-3C  MV-105 Tray Cable, MC-HL Medium Voltage Cable, 250-3C Hazardous Location Power Cable, 250-3C Orange PVC Jacketed MV Cable.\u003cbr\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cspan\u003eConstructions:\u003c\/span\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eConductor: \u003c\/strong\u003eClass B compressed stranded bare copper per ASTM B3 and B8 (Tinned Copper per ASTM B33 optional)\u003cbr\u003e\u003cstrong\u003eConductor Shield: \u003c\/strong\u003eSemi-conducting cross-linked copolymer\u003cbr\u003e\u003cstrong\u003eInsulation: \u003c\/strong\u003e420 Mils No Lead Ethylene Propylene Rubber (NL-EPR) 133% Insulation Level\u003cbr\u003e\u003cstrong\u003eInsulation Shield:\u003c\/strong\u003e Strippable semi-conducting cross-linked copolymer\u003cbr\u003e\u003cstrong\u003eCopper Tape Shield: \u003c\/strong\u003eHelically wrapped 5 mil copper tape with 25% overlap\u003cbr\u003e\u003cstrong\u003eGrounding Conductor:\u003c\/strong\u003e Class B compressed stranded bare copper ground per ASTM B3 and B8 (Tinned Copper per ASTM B33 optional)\u003cbr\u003e\u003cstrong\u003eFiller: \u003c\/strong\u003eWax paper filler\u003cbr\u003e\u003cstrong\u003eBinder: \u003c\/strong\u003ePolypropylene tape\u003cbr\u003e\u003cstrong\u003eArmor:\u003c\/strong\u003e ARMOR-X Continuous Corrugated Welded Armor\u003cbr\u003e\u003cstrong\u003eOverall Jacket:\u003c\/strong\u003e Polyvinyl Chloride (PVC) \u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003eStandards :\u003c\/h3\u003e\n\u003cp\u003e• ASTM B3 Soft or Annealed Copper Wire\u003cbr\u003e• ASTM B8 Concentric-Lay-Stranded Copper Conductors\u003cbr\u003e• ASTM B33 Standard Specification for Tin-Coated Soft or Annealed Copper Wire\u003cbr\u003e• UL 1072 Medium-Voltage Power Cables\u003cbr\u003e• UL 1685 FT4 Vertical-Tray Fire Propagation and Smoke Release Test\u003cbr\u003e• ICEA S-93-639 (NEMA WC 74) 5-46 KV Shielded Power Cable\u003cbr\u003e• IEEE 1202 FT4 Flame Test (70,000) BTU\/hr Vertical Tray Test\u003cbr\u003e\u003c\/p\u003e\n\u003ch3\u003eSpecifications: \u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eConductor size\u003c\/strong\u003e:  250 MCM\u003cbr\u003e\u003cstrong\u003eNo of Strands\u003c\/strong\u003e: 37\u003cbr\u003e\u003cstrong\u003eDiameter Over Conductor:\u003c\/strong\u003e 0.558 inch\u003cbr\u003e\u003cstrong\u003eDiameter Over Insulation:\u003c\/strong\u003e  1.444 inch\u003cbr\u003e\u003cstrong\u003eDiameter Over Insulation Shield:\u003c\/strong\u003e 1.504 inch\u003cbr\u003e\u003cstrong\u003eGround\u003c\/strong\u003e:   1x3 AWG\u003cbr\u003e\u003cstrong\u003eDiameter Over armor:\u003c\/strong\u003e 3.850 inch\u003cbr\u003e\u003cstrong\u003eJacket Thickness:\u003c\/strong\u003e  90 mil\u003cbr\u003e\u003cstrong\u003eApprox. OD:\u003c\/strong\u003e  4.030 inch\u003cbr\u003e\u003cstrong\u003eCopper Weight (lb\/1000ft\u003c\/strong\u003e): 2589\u003cbr\u003e\u003cstrong\u003eApprox. Weight  (lb\/1000ft\u003c\/strong\u003e): 7351\u003cbr\u003e\u003cstrong\u003eMax Pull Tension (lb)\u003c\/strong\u003e: 6000\u003cbr\u003e\u003cstrong\u003eMin Bending Radius\u003c\/strong\u003e:  28.2 inch\u003c\/p\u003e","brand":"Nassau National Cable","offers":[{"title":"Default Title","offer_id":64608681034097,"sku":"NNC8888ER","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/Untitleddesign_8258265a-fada-42f3-8ad5-383f79a21ca7.png?v=1789461521","url":"https:\/\/nassaunationalcable.com\/products\/250-mcm-3c-type-mv-105-copper-35kv-nlepr-insulation-133-il-armor-x-orange-pvc-jacket","provider":"NassauNationalCable","version":"1.0","type":"link"}