{"product_id":"250-mcm-3c-mv105-5kv-epr-pvc-133-medium-voltage-power-cable","title":"250 MCM 3C MV105 5kV EPR\/PVC 133% Medium Voltage Power Cable","description":"\u003cp\u003e[pdf] \u003cembed src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/CatalogC12.pdf?v=1731126957\"\u003e [\/pdf]\u003c\/embed\u003e\u003c\/p\u003e\n\u003cstyle type=\"text\/css\"\u003e\u003c!--td {border: 1px solid #cccccc;}br {mso-data-placement:same-cell;}--\u003e\u003c\/style\u003e\n\u003ch2\u003e\n\u003cstrong\u003e\u003cspan data-sheets-root=\"1\"\u003e250 AWG 3C MV105 5kV EPR\/PVC 133% Medium Voltage Power Cable\u003c\/span\u003e\u003c\/strong\u003e\u003cbr\u003e\n\u003c\/h2\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cspan data-sheets-root=\"1\"\u003eAllowable ampacity\u003cspan\u003e \u003c\/span\u003efor\u003cspan\u003e \u003c\/span\u003e\u003c\/span\u003e\u003c\/strong\u003e\u003cspan data-sheets-root=\"1\"\u003e250 MCM 3C MV105 5kV EPR\/PVC 133% Medium Voltage Power Cable\u003c\/span\u003e\u003cstrong\u003e\u003cspan data-sheets-root=\"1\"\u003e: 315 amps\u003cspan\u003e Duct\u003c\/span\u003e\u003c\/span\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cspan data-sheets-root=\"1\"\u003e\u003cspan\u003eAllowable ampacity for \u003c\/span\u003e\u003c\/span\u003e\u003c\/strong\u003e\u003cspan data-sheets-root=\"1\"\u003e250 MCM 3C MV105 5kV EPR\/PVC 133% Medium Voltage Power Cable\u003c\/span\u003e\u003cstrong\u003e\u003cspan data-sheets-root=\"1\"\u003e\u003cspan\u003e: 315 amps Conduit in Air\u003c\/span\u003e\u003c\/span\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eApplication:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003e•\u003c\/strong\u003e Aerial installations\u003cbr\u003e• Open trays\u003cbr\u003e• Direct buried \u003cbr\u003e• Metal racks\u003cbr\u003e• Open trays\u003cbr\u003e• Troughs or raceway\u003cbr\u003e• These cables are capable of operating continuously at a maximum conductor temperature of 105°C for normal operation, 140°C for emergency overload conditions, and 250°C for short circuit conditions, and are rated at 5,000V, 100% (grounded system) and 133% insulation levels (ungrounded system).\u003cbr\u003e\u003c\/span\u003e\u003cspan\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eScope:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cspan\u003eThis specification covers three conductor EPR (ethylene propylene rubber) insulated, shielded, thermoplastic jacketed power cables with grounding conductor for use in aerial installations, metal racks, open trays, troughs, or continuous rigid cable supports. These cables are capable of operating continuously at a temperature of 105°C for normal operations, 140°C for emergency overload conditions, and 250°C for short circuit conditions, and are rated at 5,000V, 100% (grounded system) and 133% insulation levels (ungrounded system).\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\n\u003cstrong\u003eAlso Known As:\u003c\/strong\u003e\u003cbr\u003e\n\u003c\/h3\u003e\n\u003cp\u003e250 MCM 3C MV105 Cable, Medium Voltage Power Cable, Power Cable, 250 MCM 3C EPR\/PVC Cable, MV105 Power Cable, 250 MCM 3C MV105 EPR\/PVC Cable.\u003c\/p\u003e\n\u003ch3\u003e\n\u003cstrong\u003eConstruction:\u003c\/strong\u003e\u003cstrong\u003e\u003c\/strong\u003e\n\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eConductors:\u003c\/strong\u003e \u003cbr\u003e\u003cbr\u003eThe conductor shall be Class B compressed concentric stranded bare copper in accordance with ASTM Specs B3 and B8 and ICEA Part 2, Section 2.1 and 2.5\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eConductor Shield:\u003c\/strong\u003e\u003cbr\u003e\u003cbr\u003eThe conductor shall be shielded with an extruded semi-conducting thermosetting polymeric layer, which shall be firmly bonded to the insulation. The thickness shall be in accordance with the referenced standards.\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eInsulation:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe insulation shall be EPR (ethylene propylene rubber) meeting the requirements of the referenced standards. The average thickness shall be 0.090\" and the minimum spot thickness shall be not less than 90% of the average thickness\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eInsulation Shield:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe insulation shall be shielded with an extruded semi-conducting thermosetting polymeric layer which shall be identified as being semi-conducting. Over this layer shall be applied a helically wrapped 5-mil copper tape.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eGrounding Conductor:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe ground conductor shall be Class B compressed concentric stranded bare copper in accordance with ASTM B3 and B8.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eAssembly:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe insulated and shielded power conductors shall be cabled round with fillers and with a grounding conductor in one outer interstice and covered with a binder tape.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eJacket:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe cable shall be covered with a black PVC jacket conforming to the requirements specified for polyvinyl chloride in ICEA. The average thickness shall be in accordance with the referenced standards and the minimum spot thickness shall be not be less than 80% of the average thickness. The jacket will be sunlight resistant and will meet the requirements of the IEEE 1202\u003c\/p\u003e\n\u003ch4\u003e\u003cstrong\u003eSpecifications:\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cp\u003e\u003cstrong\u003e• Size:\u003c\/strong\u003e\u003cspan\u003e 250 MCM\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Conductor Diameter (In):\u003c\/strong\u003e\u003cspan\u003e 0.558 \u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Grd. Cond. Size:\u003c\/strong\u003e\u003cspan\u003e 3 AWG\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Extruded Insulation Shield Diameter (In):\u003c\/strong\u003e\u003cspan\u003e 0.853 \u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Jacket Thickness (In):\u003c\/strong\u003e\u003cspan\u003e 0.110\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Approx. O.D (In):\u003c\/strong\u003e\u003cspan\u003e 2.123\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Ampacity* Duct:\u003c\/strong\u003e\u003cspan\u003e 315\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Ampacity* Conduit in Air:\u003c\/strong\u003e\u003cspan\u003e 315\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e\u003c\/strong\u003e\u003cstrong\u003e•\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eApprox.\u003c\/strong\u003e\u003cstrong\u003e Net Weight lbs.\/Mft.:\u003c\/strong\u003e\u003cspan\u003e 3868\u003c\/span\u003e\u003c\/p\u003e","brand":"Nassau National Cable","offers":[{"title":"Default Title","offer_id":51896763548017,"sku":"NNC030345","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/1_00d237fa-10f9-40b1-a58b-af4c91f2e1ad.png?v=1763009237","url":"https:\/\/nassaunationalcable.com\/products\/250-mcm-3c-mv105-5kv-epr-pvc-133-medium-voltage-power-cable","provider":"NassauNationalCable","version":"1.0","type":"link"}