{"product_id":"25-8-3-uf-b-stranded-copper-underground-feeder-cable-gray-600v","title":"25' 8\/3 UF-B Stranded Copper Underground Feeder Cable Gray 600V","description":"\u003cp\u003e[pdf] \u003cembed type=\"application\/pdf\" height=\"\" width=\"\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/Underground_Feeder_Cable.pdf?v=1622804282\"\u003e [\/pdf] [short]\u003c\/embed\u003e\u003c\/p\u003e\n\u003ch2\u003e8\/3 UF-B Stranded Copper Underground Feeder Cable 600V\u003c\/h2\u003e\n\u003cp\u003e\u003cb\u003eAllowable Ampacity for 8\/3 Underground Feeder Cable UF-B Copper 600V(Direct Burial): 40 Amps\u003c\/b\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cb\u003eAllowable Ampacity 8\/3 Underground Feeder Cable UF-B Copper 600V in Duct: 40 Amps\u003c\/b\u003e\u003cb\u003e\u003c\/b\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cb\u003e8\/3 UF-B Applications:\u003c\/b\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cspan style=\"font-weight: 400;\"\u003eAn underground feeder cable's prime purpose is to bring the power from the residential, commercial, and industrial buildings to outdoor constructions, which include pumps and lighting constructions. The electrical cable is suitable for direct burial, as well as direct exposure to the sunlight. It is permitted for use as a feeder or branch circuit cable if provided with overcurrent protection. Copper Underground Feeder Cable UF-B has a rating of 600 volts.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cb\u003eAlso Known As: \u003c\/b\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cspan style=\"font-weight: 400;\"\u003e8\/3 Copper Underground Feeder Cable, 8\/3 Copper Direct Burial Feeder Cable, 8\/3 Branch Circuit Wiring Cable, 8\/3 UF-B Wire, 8\/3 Copper Direct Earth Burial Cable, 8\/3 Copper Branch Circuit Cable, 8\/3 UF-B Direct Burial Wire, 8\/3 UF Wire, 8\/3 direct burial wire, 8\/3 underground wire, 8\/3 outdoor wire, 8\/3 underground electrical wire, 8\/3 uf b wire w ground, \u003cspan data-sheets-root=\"1\"\u003e8\/3 UF-B cable, 8\/3 underground feeder wire, 8\/3 UF cable direct burial, UF-B 8\/3 copper wire 600 volt, 8\/3 electrical underground cable, 8 gauge UF-B wire, 8\/3 underground cable stranded, 8 3 UF cable copper 600V, direct burial 8\/3 copper cable, UF-B wire 8 gauge 3 conductor, 8 3 underground electrical wire for home, 8\/3 underground wire, underground 8\/3 wire price, 8\/3 feeder wire for shed \/ garage, 8\/3 copper wire outdoor use, 8 3 underground wire amp rating, UF-B outdoor copper wire 8\/3, 8 3 UF cable by the foot, stranded copper underground 8 gauge wire, 8 3 UF-B cable specs.\u003c\/span\u003e\u003c\/span\u003e\u003cb\u003e\u003c\/b\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cb\u003eUF-B Common Applications:\u003c\/b\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli style=\"font-weight: 400;\"\u003e\u003cspan style=\"font-weight: 400;\"\u003eUnderground Feeding\u003c\/span\u003e\u003c\/li\u003e\n\u003cli style=\"font-weight: 400;\"\u003e\u003cspan style=\"font-weight: 400;\"\u003eOutdoor Lighting\u003c\/span\u003e\u003c\/li\u003e\n\u003cli style=\"font-weight: 400;\"\u003e\u003cspan style=\"font-weight: 400;\"\u003eOutdoor Outlets\u003c\/span\u003e\u003c\/li\u003e\n\u003cli style=\"font-weight: 400;\"\u003e\u003cspan style=\"font-weight: 400;\"\u003eDirect Burial\u003c\/span\u003e\u003c\/li\u003e\n\u003cli style=\"font-weight: 400;\"\u003e\u003cspan style=\"font-weight: 400;\"\u003eWet or Damp Locations\u003c\/span\u003e\u003c\/li\u003e\n\u003cli style=\"font-weight: 400;\"\u003e\u003cspan style=\"font-weight: 400;\"\u003ePump Systems\u003c\/span\u003e\u003c\/li\u003e\n\u003cli style=\"font-weight: 400;\"\u003e\u003cspan style=\"font-weight: 400;\"\u003eHVAC Systems\u003c\/span\u003e\u003c\/li\u003e\n\u003cli style=\"font-weight: 400;\"\u003e\u003cspan style=\"font-weight: 400;\"\u003eUnderground Branch Circuits\u003c\/span\u003e\u003c\/li\u003e\n\u003cli style=\"font-weight: 400;\"\u003e\u003cspan style=\"font-weight: 400;\"\u003eIndoor Applications Exposed to Moisture\u003c\/span\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cb\u003eParticular applications for size 8\/3 UF-B:\u003c\/b\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cb\u003e240V Circuits With a Neutral\u003c\/b\u003e\u003cb\u003eSubpanels\u003c\/b\u003e\u003cb\u003eWell Pumps\u003c\/b\u003e\u003cb\u003eLarger HVAC Systems\u003c\/b\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cb\u003e\u003cbr\u003e\u003c\/b\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cb\u003e8\/3 UF-B Standards:\u003c\/b\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli style=\"font-weight: 400;\"\u003e\u003cspan style=\"font-weight: 400;\"\u003eUl Standard 493 for Thermoplastic-Insulated Underground Feeder and Branch Circuit Cables\u003c\/span\u003e\u003c\/li\u003e\n\u003cli style=\"font-weight: 400;\"\u003e\u003cspan style=\"font-weight: 400;\"\u003eFor use in interior wiring in wet, dry or corrosive locations under recognized wiring methods of the National Electrical Code (NEC)\u003c\/span\u003e\u003c\/li\u003e\n\u003cli style=\"font-weight: 400;\"\u003e\u003cspan style=\"font-weight: 400;\"\u003eAcceptable to be installed as a Non-Metallic Sheathed Cable following NEC Article 339-3 (4)\u003c\/span\u003e\u003c\/li\u003e\n\u003cli style=\"font-weight: 400;\"\u003e\u003cspan style=\"font-weight: 400;\"\u003eAcceptable for use per NEC Articles 300-4(b) and 339\u003c\/span\u003e\u003c\/li\u003e\n\u003cli style=\"font-weight: 400;\"\u003e\u003cspan style=\"font-weight: 400;\"\u003eASTM - B3 and B-8\u003c\/span\u003e\u003c\/li\u003e\n\u003cli style=\"font-weight: 400;\"\u003e\u003cspan style=\"font-weight: 400;\"\u003eUL Standard 83\u003c\/span\u003e\u003c\/li\u003e\n\u003cli style=\"font-weight: 400;\"\u003e\u003cspan style=\"font-weight: 400;\"\u003eFederal Specification A-A-59544\u003c\/span\u003e\u003c\/li\u003e\n\u003cli style=\"font-weight: 400;\"\u003e\u003cspan style=\"font-weight: 400;\"\u003eRoHS\/ REACH\u003c\/span\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cb\u003e8\/3 UF-B Construction:\u003c\/b\u003e\u003c\/h3\u003e\n\u003ch4\u003e\u003ci\u003e\u003cspan style=\"font-weight: 400;\"\u003eConductor:\u003c\/span\u003e\u003c\/i\u003e\u003c\/h4\u003e\n\u003cp\u003e\u003cspan style=\"font-weight: 400;\"\u003eUF-B wire has solid or stranded Type THHN\/THWN that are laid parallel with an uninsulated grounding conductor. The conductors are made of stranded annealed bare copper.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch4\u003e\u003ci\u003e\u003cspan style=\"font-weight: 400;\"\u003eInsulation:\u003c\/span\u003e\u003c\/i\u003e\u003c\/h4\u003e\n\u003cp\u003e\u003cspan style=\"font-weight: 400;\"\u003eThe cable is insulated with a PVC jacket with a nylon covering. It is resistant to moisture, grease, corrosion, sunlight, and chemicals. \u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cb\u003e8\/3 UF-B Specifications:\u003c\/b\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli style=\"font-weight: 400;\"\u003e\n\u003cb\u003eSize AWG: \u003c\/b\u003e\u003cspan style=\"font-weight: 400;\"\u003e8\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli style=\"font-weight: 400;\"\u003e\n\u003cb\u003eWeight per 1,000 ft: \u003c\/b\u003e\u003cspan style=\"font-weight: 400;\"\u003e344 lbs\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli style=\"font-weight: 400;\"\u003e\n\u003cb\u003eOutside Diameter:\u003c\/b\u003e\u003cspan style=\"font-weight: 400;\"\u003e 1.059 Inch X.319 Inch\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli style=\"font-weight: 400;\"\u003e\n\u003cb\u003eConductors: \u003c\/b\u003e\u003cspan style=\"font-weight: 400;\"\u003e3\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli style=\"font-weight: 400;\"\u003e\n\u003cb\u003eNumber of Strands: \u003c\/b\u003e\u003cspan style=\"font-weight: 400;\"\u003e7\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli style=\"font-weight: 400;\"\u003e\n\u003cb\u003eJacket: \u003c\/b\u003e\u003cspan style=\"font-weight: 400;\"\u003ePVC\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli style=\"font-weight: 400;\"\u003e\n\u003cb\u003eInsulation and Jacket Thickness: \u003c\/b\u003e\u003cspan style=\"font-weight: 400;\"\u003e35 mils\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli style=\"font-weight: 400;\"\u003e\n\u003cb\u003eJacket Thickness: \u003c\/b\u003e\u003cspan style=\"font-weight: 400;\"\u003e45 mils\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\u003cb\u003eGround Size: \u003cspan style=\"font-weight: 400;\"\u003e8\u003c\/span\u003e\u003c\/b\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cp\u003e\u003cspan\u003e[\/short]\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eApplications:\u003c\/strong\u003e\u003cbr\u003e• Permitted for use underground including direct burial in earth as Feeder or Branch Circuit Cable where provided with overcurrent protection\u003cbr\u003e• For use in interior wiring in wet, dry or corrosive locations under recognized wiring methods of the National Electrical Code (NEC)\u003cbr\u003e• Acceptable to be installed as a Non-Metallic Sheathed Cable in accordance with NEC Article 339-3 (4)\u003cbr\u003e• Acceptable for use in accordance with NEC Articles 300-4(b) and 339\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eDescription:\u003c\/strong\u003e\u003cbr\u003eType UF-B Underground Feeder Cable's construction provides solid or stranded Type THHN\/THWN conductors laid parallel with an uninsulated grounding conductor. An outer jacket of tough PVC, provides protection against mechanical damage, moisture, chemicals and corrosion.\u003cbr\u003e• Grease and chemical resistant conductors\u003cbr\u003e• Moisture, chemical and sunlight resistant jacket\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eStandards:\u003c\/strong\u003e\u003cbr\u003eUL Standard 493 - Thermoplastic-Insulated Underground Feeder and Branch Circuit Cables\u003cbr\u003e\u003cstrong\u003eTemperature:\u003c\/strong\u003e 75°C \u003cbr\u003e\u003cstrong\u003eVoltage:\u003c\/strong\u003e 600\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e","brand":"Nassau Stock","offers":[{"title":"Default Title","offer_id":62714326057329,"sku":"NNC3753X0325","price":92.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/6-3_-1.png?v=1762458992","url":"https:\/\/nassaunationalcable.com\/products\/25-8-3-uf-b-stranded-copper-underground-feeder-cable-gray-600v","provider":"NassauNationalCable","version":"1.0","type":"link"}