{"product_id":"2-gang-explosionproof-dead-end-receptacle-assembly-enr22201-gfi","title":"2 Gang Explosionproof Dead End Receptacle Assembly ENR22201 GFI","description":"\u003cp\u003e[pdf]\u003cembed src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/Panduit_96748e8b-16dd-4fd1-99bf-b072dc224cb0.pdf?v=1730806906\" width=\"\" height=\"\" type=\"application\/pdf\"\u003e [\/pdf]\u003c\/embed\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eAbout:\u003cbr\u003e\u003cbr\u003e\u003c\/strong\u003e• The 2 Gang Explosionproof Dead End Receptacle Assembly is designed for use in hazardous locations where the risk of explosion from flammable gases, vapors, or dust exists. This assembly provides a secure and reliable electrical connection while protecting against potential ignition sources.\u003cbr\u003e• It is constructed from durable materials that meet stringent explosionproof standards, ensuring safety and longevity in industrial environments.\u003cbr\u003e• The receptacle features weather-tight seals to prevent moisture and contaminants from entering, making it suitable for outdoor and harsh conditions. Easy to install, it allows for efficient power distribution in various applications, including manufacturing, oil and gas, and chemical processing.\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eAlso Known As:\u003c\/strong\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003eExplosionproof Receptacle Assembly, Hazardous Location Receptacle, Dead End Receptacle, Explosionproof Electrical Outlet, Industrial Receptacle Assembly, Two Gang Receptacle Assembly.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eSpecification:\u003c\/strong\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003ctable style=\"width: 74.4526%; height: 208.703px;\" width=\"100%\" data-mce-style=\"width: 74.4526%; height: 265.719px;\"\u003e\n\u003ctbody\u003e\n\u003ctr style=\"height: 10px;\" data-mce-style=\"height: 39.1875px;\"\u003e\n\u003ctd style=\"width: 180.781px; text-align: center; height: 10px;\" data-mce-style=\"width: 180.781px; text-align: center; height: 39.1875px;\"\u003e\u003cstrong\u003eProduct Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 211.219px; text-align: center; height: 10px;\" data-mce-style=\"width: 211.219px; text-align: center; height: 39.1875px;\"\u003e\n\u003cp\u003eTwo Gang Receptacle Assembly\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 33.4375px;\" data-mce-style=\"height: 33.4375px;\"\u003e\n\u003ctd style=\"width: 180.781px; text-align: center; height: 33.4375px;\" data-mce-style=\"width: 180.781px; text-align: center; height: 33.4375px;\"\u003e\u003cstrong\u003eMaterial\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 211.219px; text-align: center; height: 33.4375px;\" data-mce-style=\"width: 211.219px; text-align: center; height: 33.4375px;\"\u003eCopper-free Aluminum\u003cbr\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\" data-mce-style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 180.781px; text-align: center; height: 19.5938px;\" data-mce-style=\"width: 180.781px; text-align: center; height: 19.5938px;\"\u003e\u003cstrong\u003eVoltage Rating\u003cbr\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 211.219px; text-align: center; height: 19.5938px;\" data-mce-style=\"width: 211.219px; text-align: center; height: 19.5938px;\"\u003e125 Vac\u003cbr\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 33.4375px;\" data-mce-style=\"height: 33.4375px;\"\u003e\n\u003ctd style=\"width: 180.781px; text-align: center; height: 33.4375px;\" data-mce-style=\"width: 180.781px; text-align: center; height: 33.4375px;\"\u003e\u003cstrong\u003e\u003cspan\u003eLength\/depth\u003cbr\u003e\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 211.219px; text-align: center; height: 33.4375px;\" data-mce-style=\"width: 211.219px; text-align: center; height: 33.4375px;\"\u003e8 In\u003cbr\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\" data-mce-style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 180.781px; text-align: center; height: 19.5938px;\" data-mce-style=\"width: 180.781px; text-align: center; height: 19.5938px;\"\u003e\u003cstrong\u003eHeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 211.219px; text-align: center; height: 19.5938px;\" data-mce-style=\"width: 211.219px; text-align: center; height: 19.5938px;\"\u003e6.72 In\u003cbr\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 33.8594px;\" data-mce-style=\"height: 33.8594px;\"\u003e\n\u003ctd style=\"width: 180.781px; text-align: center; height: 33.8594px;\" data-mce-style=\"width: 180.781px; text-align: center; height: 33.8594px;\"\u003e\u003cstrong\u003eWidth\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 211.219px; text-align: center; height: 33.8594px;\" data-mce-style=\"width: 211.219px; text-align: center; height: 33.8594px;\"\u003e7.56 In\u003cbr\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 58.7812px;\" data-mce-style=\"height: 58.7812px;\"\u003e\n\u003ctd style=\"width: 180.781px; text-align: center; height: 58.7812px;\" data-mce-style=\"width: 180.781px; text-align: center; height: 58.7812px;\"\u003e\u003cstrong\u003ePart No.\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 211.219px; text-align: center; height: 58.7812px;\" data-mce-style=\"width: 211.219px; text-align: center; height: 58.7812px;\"\u003e\n\u003cbr\u003eENR22201 GFI\u003cbr\u003e\u003cbr\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e\u003cbr\u003e\u003cstrong\u003eFeatures:\u003cbr\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e• Allows for a single part number to be specified, ordered, and delivered on-site, significantly reducing the cost of order processing, material handling, and the risk of material misplacement.\u003cbr\u003e• Includes all of the value-added features of the ENR Receptacle.\u003cbr\u003e• Equipped with a GFCI (Ground Fault Circuit Interrupter) to protect personnel against potential injury due to unwanted ground faults.\u003cbr\u003e• Field installation is straightforward and can be accomplished with standard tools.\u003cbr\u003e• Designed as a two-gang assembly for increased connectivity.\u003cbr\u003e• Suitable for use in dust-ignitionproof environments, rain-tight, and wet locations, ensuring reliability in harsh conditions.\u003cbr\u003e\u003c\/p\u003e","brand":"Eaton","offers":[{"title":"Default Title","offer_id":51894209806705,"sku":"ENR22201 GFI","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/LCDX20-38D-X_43_02dd2262-861b-4ff9-bb8f-74b3a83d6500.jpg?v=1763008861","url":"https:\/\/nassaunationalcable.com\/products\/2-gang-explosionproof-dead-end-receptacle-assembly-enr22201-gfi","provider":"NassauNationalCable","version":"1.0","type":"link"}