{"product_id":"2-0-awg-3c-type-mv-105-copper-15kv-nlepr-insulation-133-il-aia-red-lszh-tp-jacket","title":"2\/0 AWG 3C Type MV-105 Copper 15kV NLEPR Insulation 133% IL AIA Red LSZH-TP Jacket","description":"\u003cp\u003e[short] [pdf] \u003cembed src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/SOUTHWIRE_SPEC46460-003_2.pdf?v=1755680365\"\u003e [\/pdf]\u003c\/embed\u003e\u003c\/p\u003e\n\u003ch2\u003e\u003cspan data-sheets-root=\"1\"\u003e2\/0 AWG 3C Type MV-105 Copper 15kV NLEPR Insulation 133% IL AIA Red LSZH-TP Jacket\u003c\/span\u003e\u003c\/h2\u003e\n\u003ch3\u003eApplication:\u003c\/h3\u003e\n\u003cp\u003eSouthwire’s 15KV cables are suited for use in wet and dry areas, conduits, ducts, troughs, trays, direct burial, and where superior electrical properties are desired. These cables are capable of operating continuously at the conductor temperature not in excess of 105°C for normal operation, 140°C for emergency overload, and 250°C for short circuit conditions. Rated at -25°C for cold bend. For uses in Class I and II, Division 2 hazardous locations per NEC Article 501 and 502.Rated for 1000 lbs.\/FT maximum sidewall pressure. Type MV-105 Three Conductor Copper, 220 Mils No Lead Ethylene Propylene Rubber (NL-EPR) 133% Insulation Level, Tape Shield, Aluminum Interlocked Armor (AIA), Thermoplastic SOLONON Low Smoke Zero Halogen (LSZH-TP) Jacket. Silicone.\u003cbr\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003ch3\u003eAlso known as:\u003cbr\u003e\n\u003c\/h3\u003e\n\u003cp data-start=\"260\" data-end=\"287\"\u003e2\/0 AWG 3C Metal Clad (MC) Cable Control Cable with Corrugated Steel Armor Welded Armor MC 2\/0 AWG 3C Cable MC-HL (Heat and Light Resistant) Cable XLPE Insulated Control Cable 2\/0 AWG 3C PVC Jacketed Control Cable 600V Rated Control Cable MC-HL Cable 2\/0 AWG 3C with Ground Corrugated Armor MC Cable\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eConstruction:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eConductor:\u003cbr\u003e\u003c\/strong\u003eClass B compressed stranded bare copper per ASTM B3 and ASTM B8 (Tinned Copper per ASTM B33 optional)\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003eConductor Shield: \u003cbr\u003e\u003c\/strong\u003eSemi-conducting cross-linked copolymer\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eInsulation\u003c\/strong\u003e:\u003cbr\u003e 220 Mils No Lead Ethylene Propylene Rubber (NL-EPR) 133% Insulation Level\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003eInsulation Shield: \u003cbr\u003e\u003c\/strong\u003eStrippable semi-conducting cross-linked copolymer\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003eCopper Tape Shield: \u003c\/strong\u003e\u003cbr\u003eHelically wrapped 5 mil copper tape with 25% overlap\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003eGrounding Conductor:\u003cbr\u003e\u003c\/strong\u003eClass B compressed stranded bare copper ground per ASTM B3 and ASTM B8 (Tinned Copper per ASTM B33 optional)\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eFiller\u003c\/strong\u003e:\u003cbr\u003eWax paper filler\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eBinder\u003c\/strong\u003e:\u003cbr\u003ePolypropylene tape\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eArmor\u003c\/strong\u003e:\u003cbr\u003eAluminum Interlocked Armor (AIA)\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eOverall Jacket:\u003c\/strong\u003e\u003cbr\u003eThermoplastic SOLONON Low Smoke Zero Halogen (LSZH-TP) \u003cbr\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eStandards:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e• ASTM B3 Soft or Annealed Copper Wire\u003cbr\u003e• ASTM B8 Concentric-Lay-Stranded Copper Conductors\u003cbr\u003e• ASTM B33 Standard Specification for Tin-Coated Soft or Annealed Copper Wire\u003cbr\u003e• UL 1072 Medium-Voltage Power Cables\u003cbr\u003e• UL 1685 FT4 Vertical-Tray Fire Propagation and Smoke Release Test\u003cbr\u003e• ICEA S-93-639 (NEMA WC 74) 5-46 KV Shielded Power Cable\u003cbr\u003e• IEEE 1202 FT4 Flame Test (70,000) BTU\/hr Vertical Tray Test\u003c\/p\u003e\n\u003ch4\u003e\u003cstrong\u003eSpecifications:\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cp class=\"MsoNormal\"\u003e• \u003cstrong\u003eSize:\u003c\/strong\u003e 2\/0 AWG\u003cbr\u003e\u003cspan\u003e\u003cstrong\u003e• Number of Conductor:\u003c\/strong\u003e 3+1G\u003c\/span\u003e \u003cbr\u003e• \u003cstrong\u003eNumber of Strands:\u003c\/strong\u003e  19\u003cbr\u003e• \u003cstrong\u003eDiameter Over Conductor (inch):\u003c\/strong\u003e   0.405\u003cbr\u003e• \u003cstrong\u003eDiameter Over Insulation (inch):\u003c\/strong\u003e 0.883\u003cbr\u003e• \u003cstrong\u003eDiameter Over Insulation Shield (inch):\u003c\/strong\u003e  0.943\u003cbr\u003e• \u003cstrong\u003eGround No. x AWG:  \u003c\/strong\u003e1x4\u003cbr\u003e• \u003cstrong\u003eDiameter Over Armor (inch):\u003c\/strong\u003e   2.402\u003cbr\u003e• \u003cstrong\u003eJacket Thickness (mil):\u003c\/strong\u003e 75\u003cbr\u003e• \u003cstrong\u003eApprox. OD (In): \u003c\/strong\u003e2.552\u003cbr\u003e• \u003cstrong\u003eCopper Weight lb\/1000ft: \u003c\/strong\u003e1428\u003cbr\u003e• \u003cstrong\u003eApprox. Weight (Lbs\/1000'Ft):\u003c\/strong\u003e     3417\u003cbr\u003e• \u003cstrong\u003eDC Resistance @ 25°C Ω \/1000ft:\u003c\/strong\u003e  0.081\u003cbr\u003e• \u003cstrong\u003eAC Resistance @ 90°Ω \/1000ft\u003c\/strong\u003e:  0.102\u003cbr\u003e• \u003cstrong\u003eAllowable Ampacity In Duct 90\/105°C Amp :\u003c\/strong\u003e    220\/235\u003cbr\u003e•\u003cstrong\u003e Allowable Ampacity In Air 90\/105°C Amp:\u003c\/strong\u003e 245\/275\u003cbr\u003e\u003c\/p\u003e","brand":"Nassau National Cable","offers":[{"title":"Default Title","offer_id":55746040332657,"sku":"NNC587424","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/500_1.png?v=1755678844","url":"https:\/\/nassaunationalcable.com\/products\/2-0-awg-3c-type-mv-105-copper-15kv-nlepr-insulation-133-il-aia-red-lszh-tp-jacket","provider":"NassauNationalCable","version":"1.0","type":"link"}