{"product_id":"2-0-awg-3c-aluminum-mv-90-tape-shielded-xlpe-133-insulation-220-mil-15-kv","title":"2\/0 AWG 3C Aluminum MV-90 Tape Shielded XLPE 133% Insulation 220 mil 15 kV","description":"\u003cp\u003e[pdf] \u003cembed src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/mvm-04-mv90-3c-xlpe-pvc_2_1.pdf?v=1756206451\"\u003e [\/pdf]\u003c\/embed\u003e\u003c\/p\u003e\n\u003cstyle type=\"text\/css\"\u003e\u003c!--td {border: 1px solid #cccccc;}br {mso-data-placement:same-cell;}--\u003e\u003c\/style\u003e\n\u003ch2\u003e\n\u003cstrong\u003e\u003cspan data-sheets-root=\"1\"\u003e2\/0 AWG 3C Aluminum MV-90 Tape Shielded XLPE 133% Insulation 220 mil 15 kV\u003c\/span\u003e\u003c\/strong\u003e\u003cbr\u003e\n\u003c\/h2\u003e\n\u003ch3\u003e\u003cstrong\u003eApplication:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003e•\u003c\/strong\u003e\u003cspan\u003e Primary power and distribution circuits in industrial and commercial installations, power circuits in generating plants where line to ground fault current are within shield capabilities.\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e May be used in wet or dry locations, installed in raceways, duct, and open air, aerially or directly buried where permitted by NEC.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eAlso Known As:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cspan\u003e2\/0 AWG 3C MV-90 Cable, 3 Conductor Aluminum, Tape Shielded Cable, 2\/0 AWG 3C XLPE Insulation, PVC Jacket, 5kV-35kV Cable, High Voltage Cable, 2\/0 AWG 3C Aluminum MV-90, Electrical Power Cable, Multi-Conductor Cable.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eStandards:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003e•\u003c\/strong\u003e\u003cspan\u003e UL 1072\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e Medium Voltage Power Cables.\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e ICEA S-93-639\/NEMA WC74\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e 5 kV – 46 kV Shielded Power Cables.\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e ICEA S-97-682\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e Standard for Utility Shielded Power Cables Rated 5 kV– 46 kV.\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e AEIC CS8\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e Specification for Extruded Dielectric, Shielded Power Cables Rated 5 kV – 46 kV.\u003cbr\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eFeatures:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003e•\u003c\/strong\u003e\u003cspan\u003e UL Listed as MV-90.\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e Rated as Sunlight Resistance for CT use, 1\/0 AWG and larger.\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e Oil Resistance I jacket.\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e True Triple extrusion system and closed handling raw materials system, to eliminate any contact with ambient, until extrusion process ends.\u003cbr\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eConstruction:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003e•\u003c\/strong\u003e\u003cspan\u003e \u003cstrong\u003eConductor:\u003c\/strong\u003e Soft annealed uncoated copper compacted Class B per ASTM B496 or hard drawnAluminum-1350 compacted Class B per ASTM B400.\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e \u003cstrong\u003eConductor Shield:\u003c\/strong\u003e Semi conducting cross-linked polyethylene (XLPE).\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e \u003cstrong\u003eInsulation:\u003c\/strong\u003e Thermoset crosslinked polyethylene (XLPE).\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e \u003cstrong\u003eInsulation Shield:\u003c\/strong\u003e Semi conducting cross-linked polyethylene (XLPE).\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e \u003cstrong\u003eMetallic Shield:\u003c\/strong\u003e Soft annealed uncoated copper tape, 5 mil thick, 25% minimum overlap\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e \u003cstrong\u003eGrounding (Optional):\u003c\/strong\u003e One or three soft annealed bare copper or covered conductors cabled with phase conductors.\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e \u003cstrong\u003eAssembly:\u003c\/strong\u003e Conductors cabled with non hygroscopic fillers, as required and binder tape.\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e \u003cstrong\u003eJacket:\u003c\/strong\u003e  Black sunlight resistance and flame retardant polyvinyl chloride (PVC) compound.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch4\u003e\u003cstrong\u003eSpecifications:\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cp\u003e\u003cstrong\u003e• Size:\u003c\/strong\u003e\u003cspan\u003e 2\/0 AWG\u003cbr\u003e\u003cstrong\u003e• Ground Conductor Aluminum AWG:\u003c\/strong\u003e 2\u003cbr\u003e\u003cstrong\u003e• Jacket Thickness (mil):\u003c\/strong\u003e 110\u003cbr\u003e\u003cstrong\u003e• Approximate Outside Diameter (In):\u003c\/strong\u003e 2.32\u003cbr\u003e\u003cstrong\u003e• Approximate Net Weight Aluminum lb\/kft:\u003c\/strong\u003e 2320\u003c\/span\u003e\u003c\/p\u003e","brand":"Nassau National Cable","offers":[{"title":"Default Title","offer_id":52076003393905,"sku":"NNC20220MV-90","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/22222222.jpg?v=1756441801","url":"https:\/\/nassaunationalcable.com\/products\/2-0-awg-3c-aluminum-mv-90-tape-shielded-xlpe-133-insulation-220-mil-15-kv","provider":"NassauNationalCable","version":"1.0","type":"link"}