{"product_id":"18-awg-6p-individual-and-overall-shield-instrumentation-tray-cable-vntc-tc-er-600v","title":"18 AWG 6P Individual and Overall Shield Instrumentation Tray Cable VNTC TC-ER 600V","description":"\u003cp\u003e[pdf] \u003cembed src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/CatalogB6_355938e9-cfb7-48e7-92dd-f2cce498b1f5.pdf?v=1726571708\"\u003e [\/pdf]\u003c\/embed\u003e\u003c\/p\u003e\n\u003ch2\u003e\u003cspan data-sheets-root=\"1\"\u003e18 AWG 6P Individual and Overall Shield Instrumentation Tray Cable VNTC TC-ER 600V\u003c\/span\u003e\u003c\/h2\u003e\n\u003ch3\u003e\u003cstrong\u003eApplication:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003e• TC-ER SPOS Instrumentation Cables are suitable for control,instrumentation and process control circuits, where protection against electrostatic interference from both outside of the cable and from pair to pair is needed. The cables are suitable for wet or dry applications, direct burial, indoor or outdoor locations,installed in cable trays, ducts, aerially or conduits and for applications up to 600 volt and temperatures up to 90°C. TC-ER SPOS Instrumentation Cables are suitable for use in Class 1 Division 2 Hazardous locations per NEC\u003c\/strong\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eScope:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003e•\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003eThis Instrumentation Cables is UL listed under Article 340 of the NEC and is suitable for cable tray use in Class 1, Division 2 hazardous locations. The cable can be used in wet or dry locations and up to conductor temperatures of 90°C. The addition of nylon over the conductors provides excellent oil and gasoline protection.\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003e•\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003eThe individually shielded pairs and triads are completely isolated from each other by use of a polyester tape. This isolation assures maximum protection from crosstalk and common mode interference. An overall shield provides additional protection.\u003cstrong\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003e•\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003eThe flame properties meet or exceed the requirements of both the UL 70,000 BTU vertical tray flame test and the comparable IEEE-383 flame test. A 210,000 BTU rating is also available upon request.\u003c\/p\u003e\n\u003ch3\u003e\n\u003cstrong\u003eAlso Known As:\u003c\/strong\u003e\u003cbr\u003e\n\u003c\/h3\u003e\n\u003cp\u003e\u003cspan\u003e18 AWG 6P Shielded VNTC Cable, 18 AWG 6P Instrumentation Cable, 18 AWG 6P 600V VNTC Control Cable, 600V Shielded Instrumentation Tray Cable, 18 AWG 6P TC-ER Instrument Cable, VNTC Tray Cable, 18\/6P 600V Shielded Control Cable.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\n\u003cstrong\u003eConstruction:\u003c\/strong\u003e\u003cstrong\u003e\u003c\/strong\u003e\n\u003c\/h3\u003e\n\u003cp\u003eClass B, stranded per ASTM B-3 and ASTM B-8.\u003cbr\u003eConductors are type TFN listed under UL 62.\u003cbr\u003eAvailable in tinned copper upon request.\u003cstrong\u003e\u003cbr\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003ePrimary Insulation:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e105°C rated PVC and nylon jacket\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eShielding:\u003cbr\u003e\u003cbr\u003e\u003c\/strong\u003eAluminum polyester foil with 100% coverage on each pair,\u003cbr\u003ewith an overall aluminum polyester foil with 100% coverage\u003cbr\u003ewith a tinned copper drain wire in contact with all shields\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003eJacket:\u003cbr\u003e\u003cbr\u003e\u003c\/strong\u003ePolyvinyl Chloride (PVC) jacket, which is water, chemical,\u003cbr\u003esunlight and abrasion resistant\u003cbr\u003e\u003c\/p\u003e\n\u003ch4\u003e\u003cstrong\u003eSpecifications:\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003e• AWG:\u003c\/strong\u003e 18\u003cbr\u003e\u003cstrong\u003e• No. of Pairs:\u003c\/strong\u003e 6\u003cbr\u003e\u003cstrong\u003e• Nominal Jacket Thickness (In):\u003c\/strong\u003e .047\u003cbr\u003e\u003cstrong\u003e• Nominal Outside Diameter (In):\u003c\/strong\u003e .498\u003cbr\u003e\u003cstrong\u003e• Pulling Tension (Pounds):\u003c\/strong\u003e 149\u003cstrong\u003e\u003cbr\u003e\u003c\/strong\u003e\u003cstrong\u003e•\u003c\/strong\u003e \u003cstrong\u003eNominal\u003c\/strong\u003e\u003cstrong\u003e Weight 1000 FT (Pounds):\u003c\/strong\u003e 139\u003cbr\u003e\u003c\/span\u003e\u003c\/p\u003e","brand":"Nassau National Cable","offers":[{"title":"Default Title","offer_id":45209786646682,"sku":"NNC020232","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/2_f5fe549c-38fd-4ad4-87e7-bfda71095953.png?v=1759828821","url":"https:\/\/nassaunationalcable.com\/products\/18-awg-6p-individual-and-overall-shield-instrumentation-tray-cable-vntc-tc-er-600v","provider":"NassauNationalCable","version":"1.0","type":"link"}