{"product_id":"16-awg-4c-bare-copper-shielded-al-tape-tc-braid-pvc-gaalflex-tray-vfd-1405-600v-cable","title":"16 AWG 4C Bare Copper Shielded Al Tape TC Braid PVC Gaalflex Tray VFD 1405 600V Cable","description":"\u003cp\u003e[pdf] \u003cembed src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/F2143-American-Industrial-Mining-Cables_removed_7.pdf?v=1703677301\"\u003e [\/pdf]\u003c\/embed\u003e\u003c\/p\u003e\n\u003ch4\u003e\u003cstrong\u003e16 AWG 4C Bare Copper Shielded Al Tape TC Braid PVC Gaalflex Tray VFD 1405 600V Cable\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cp\u003e\u003cstrong\u003eAllowable Ampacity\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003efor 16 AWG 4C Bare Copper Shielded Al Tape TC Braid PVC Gaalflex Tray VFD 1405 600V Cable\u003cstrong\u003e\u003cspan\u003e:\u003c\/span\u003e\u003cspan\u003e \u003c\/span\u003e100 Amps\u003c\/strong\u003e\u003c\/p\u003e\n\u003ch4\u003e\u003cstrong\u003eAbout:\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cp\u003eThe Gaalflex Bare Copper Shielded Al Tape TC Braid PVC Tray VFD 1405 600V Cable is a specialized cable designed for use in various industrial applications. It features a construction that includes bare copper conductors, shielding with aluminum tape and TC (Tinned Copper) braid, and a PVC jacket.\u003c\/p\u003e\n\u003ch4\u003e\n\u003cstrong\u003eAlso K\u003c\/strong\u003e\u003cstrong\u003enown As:\u003c\/strong\u003e\n\u003c\/h4\u003e\n\u003cp\u003e\u003cstrong\u003e•\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003eGaalflex VFD 1405 600V Cable specifications\u003cbr\u003e\u003cstrong\u003e•\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003eBare Copper Shielded Al Tape TC Braid PVC Tray Cable\u003cbr\u003e\u003cstrong\u003e•\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003eInstrumentation cable standards\u003cbr\u003e\u003cstrong\u003e•\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003eTray cable applications and usage\u003cbr\u003e\u003cstrong\u003e•\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003eVFD cable for motor drives\u003c\/p\u003e\n\u003ch4\u003e\u003cstrong\u003eApplication:\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cp\u003e\u003cstrong\u003e•\u003cspan\u003e \u003c\/span\u003eShielding:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003eThis cable is shielded, which means it provides protection against electromagnetic interference (EMI) and radio-frequency interference (RFI). This shielding ensures stable and reliable signal transmission, critical for VFD systems.\u003cstrong\u003e\u003cbr\u003e•\u003cspan\u003e \u003c\/span\u003eBare Copper Conductor:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003eThe use of bare copper conductors ensures excellent electrical conductivity, reducing energy losses and allowing for efficient power transmission.\u003cstrong\u003e\u003cbr\u003e•\u003cspan\u003e \u003c\/span\u003eAluminum Tape and TC Braid Shielding:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003eThe combination of aluminum tape and tinned copper (TC) braid shielding provides enhanced protection against EMI and RFI, making it ideal for VFD applications where signal integrity is crucial.\u003cbr\u003e\u003cstrong\u003e•\u003cspan\u003e \u003c\/span\u003ePVC Jacket:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003eThe PVC (Polyvinyl Chloride) jacket offers durability and resistance to environmental factors, making the cable suitable for both indoor and outdoor tray installations.\u003cbr\u003e\u003cstrong\u003e•\u003cspan\u003e \u003c\/span\u003e600V Rating:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003eWith a 600V rating, this cable can handle the voltage requirements of many VFD systems commonly used in industrial settings.\u003c\/p\u003e\n\u003ch4\u003e\u003cstrong\u003eStandards:\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cp\u003e\u003cstrong\u003e•\u003cspan\u003e \u003c\/span\u003eNational Electrical Code (NEC):\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003eFor general electrical installation guidelines.\u003cstrong\u003e\u003cbr\u003e•\u003cspan\u003e \u003c\/span\u003eUL (Underwriters Laboratories):\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003eEnsuring safety and performance.\u003cstrong\u003e\u003cbr\u003e•\u003cspan\u003e \u003c\/span\u003eIEEE Standards:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003eFor specific applications like VFDs.\u003cstrong\u003e\u003cbr\u003e•\u003cspan\u003e \u003c\/span\u003eLocal Electrical Codes:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003eLocal regulations for compliance.\u003c\/p\u003e\n\u003ch4\u003e\u003cstrong\u003eConstruction:\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cp\u003e\u003cstrong\u003e•\u003cspan\u003e \u003c\/span\u003eConductor:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003eflexible red copper conductor Cl. 5, acc. to IEC 60228, DIN VDE 0295 and UL standard 83\u003cstrong\u003e\u003cbr\u003e•\u003cspan\u003e \u003c\/span\u003eInsulation:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003efrom 18 AWG up to 16 AWG: GAALTHERM 520 from 14 AWG and over: GAALTHERM 591\u003cstrong\u003e\u003cbr\u003e•\u003cspan\u003e \u003c\/span\u003eCores color:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003e3x..+3g..: 3 black conductors numbered + 3 green-yellow conductors divided in 3 inertstices 3x..+1g.. \/ 4g..+(2x..) or 4g..+(2x..+2x..): black cores with consecutive numbers acc. to EN 50334 + green\/yellow\u003cstrong\u003e\u003cbr\u003e•\u003cspan\u003e \u003c\/span\u003eStranding:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003e3x..+1g..: cores twisted together + fillers 3x..+3g..: phase units laid up with earth-conductors in interstices 4g..+(2x..) or 4g..+(2x..+2x..): control cores twisted in pair(s) and screened, supply cores and control screened pair(s) twisted together\u003cstrong\u003e\u003cbr\u003e•\u003cspan\u003e \u003c\/span\u003eIndividual screen:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003e4g..+(2x..) or 4g..+(2x..+2x..): aluminium tape + PETP foil and tinned copper braid 85% coverage +\/- 5%\u003cstrong\u003e\u003cbr\u003e•\u003cspan\u003e \u003c\/span\u003eOverall screen:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003ealuminium tape + PETP foil and tinned copper braid 85% coverage +\/- 5%\u003cstrong\u003e\u003cbr\u003e•\u003cspan\u003e \u003c\/span\u003eOuter Sheath:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003eblack (similar RAL 9005), GAALTHERM 520\u003c\/p\u003e\n\u003ch4\u003e\u003cstrong\u003eFeatures:\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cp\u003e\u003cstrong\u003e•\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003eUV resistant\u003cbr\u003e\u003cstrong\u003e•\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003eoutdoor use\u003cbr\u003e\u003cstrong\u003e•\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003einstallation in hazardous areas\u003cbr\u003e\u003cstrong\u003e•\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003eacc. to UL 2277 WTTC or Flexible Motor Supply\u003cbr\u003e\u003cstrong\u003e•\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003eacc. to UL 1277 (Oil-resistant according to UL OIL RES I and Water-resistant, UL 90°C Dry or 90°C Wet )\u003cbr\u003e\u003cstrong\u003e•\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003eUL only for TC-ER use\u003cbr\u003e\u003cstrong\u003e•\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003eon request c(UL) type CIC\/TC FT4, AWM I\/II A\/B FT4\u003cbr\u003e\u003cstrong\u003e•\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003eon request DIRECT BURIAL\u003cbr\u003e\u003cstrong\u003e•\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003eacc. to to NFPA 79 2007 and NEC 336.10(7) Class 1, Div. 2 Art. 336, 392, 501\u003cbr\u003e\u003cstrong\u003e•\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003esuitable for application acc. to EN 55011, DIN VDE 0875 and EN 61800-3\u003cbr\u003e\u003cstrong\u003e•\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003esuitable for chain application, see technical data*\u003cbr\u003e\u003cstrong\u003e•\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003eRoHS and CE approval\u003c\/p\u003e\n\u003ch4\u003e\n\u003cstrong\u003eSpecifications:\u003c\/strong\u003e\u003cstrong\u003e\u003cbr\u003e\u003c\/strong\u003e\n\u003c\/h4\u003e\n\u003cp\u003e\u003cstrong\u003e• No. of cores x cross section n x AWG\/MCM:\u003c\/strong\u003e\u003cspan\u003e 4 G 16\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Outer Ø inches\/mm ±10%:\u003c\/strong\u003e\u003cspan\u003e 0,38 - 9,7\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Nominal voltage:\u003c\/strong\u003e\u003cspan\u003e UL 1277 TC-ER-600 V, UL 2277 WTTC \/ Flexible Motor Supply-1000 V, IEC: Uo\/U 600\/1000 V\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Temperature range UL:\u003cspan\u003e  \u003c\/span\u003e\u003c\/strong\u003eup to 90°C Fixed laying: - 40 oC up to + 105 oC Flexible installation: - 5 oC up to + 105 oC\u003cbr\u003e\u003cstrong\u003e• Min. bending radius:\u003c\/strong\u003e\u003cspan\u003e Fixed laying: 6 x d Flexible application: 20 x d\u003cbr\u003e\u003cstrong\u003e• Copper weight Lbs\/Mft: \u003c\/strong\u003e58,1\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Cable weight approx. Lbs\/Mft:\u003c\/strong\u003e\u003cspan\u003e 126,1\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Part Number:\u003c\/strong\u003e\u003cspan\u003e 33290F70041A16\u003c\/span\u003e\u003c\/p\u003e","brand":"Elettrotek Kabel","offers":[{"title":"Default Title","offer_id":62933794947441,"sku":"33290F70041A16","price":1.73,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/308_f3075a06-3be3-4e9a-98a6-11d4707aeda1.png?v=1762987831","url":"https:\/\/nassaunationalcable.com\/products\/16-awg-4c-bare-copper-shielded-al-tape-tc-braid-pvc-gaalflex-tray-vfd-1405-600v-cable","provider":"NassauNationalCable","version":"1.0","type":"link"}