{"product_id":"114-24-2243-500-mcm-okoguard-okolon-ts-cpe-type-mv-90-2-4-kv-nonshielded-power-cable","title":"114-24-2243 500 MCM Okoguard - Okolon  TS-CPE Type MV-90  2.4 kV Nonshielded Power Cable","description":"\u003cp\u003e\u003cstrong\u003e114-24-2243 500 MCM Okoguard - Okolon TS-CPE Type MV-90 2.4 kV Nonshielded Power Cable\u003c\/strong\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eInsulation\u003c\/strong\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003eOkoguard is Okonite's registered trade name for its exclusive ethylene-propylene rubber\u003cbr\u003e(EPR) based, thermosetting compound, whose optimum balance of electrical and physical properties is unequalled in other solid dielectrics. Okoguard insulation, with the distinctive red color and a totally inte- grated EPR system, provides the optimum balance for long, problem free service.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eApplications\u003c\/strong\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003eOkoguard-Okolon TS-CPE 2 .4 kV cables are heavy duty nonshielded cables designed for use at up to 2.4 kV phase-to-phase in wet or dry locations in accordance with NEC Section 310.10. Okoguard-Okolon TS-CPE nonshielded ca- bles are recommended for power distribution and motor circuits in generating plants and substations; in industrial and commercial buildings. Single conductors may be installed in indus- trial or commercial occupancies in triplexed or random lay in any raceway or duct in wet or dry locations, or in open runs as permitted by NEC Article 396. Sizes 1\/0 AWG and larger, may be installed in cable trays where permitted by NEC Sec- tion 392.10.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eConductors:\u003c\/strong\u003eAnnealed uncoated copper compact stranded per ASTM B-496.\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003eStrand Screen: \u003c\/strong\u003eExtruded semiconducting EPR strand screen. Meets or exceeds elec- trical and physical requirements of ICEA. S-96-659\/NEMA WC71 and UL 1072.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eInsulation:\u003c\/strong\u003e\u003cbr\u003eMeets or exceeds electrical and physical requirements of ICEA S-96- 659\/NEMA WC71 and UL 1072.\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003eJacket:\u003cbr\u003e\u003c\/strong\u003eMeets or exceeds electrical and physical requirements of ICEA S-96-659\/NEMA WC71 for chlorinated polyethylene jackets. UL listed as Type MV-90, sunlight resistant, -40°C and for use in cable tray in accordance with UL 1072. CSA listed as RW90 as 5kV non shielded (FT4 1\/0 and larger) -40°C in accordance with CSA C22.2 No 38. 1\/C non-shielded cables can surface dis- charge in service when in a random phase spacing or when in contact with grounded surfaces.\u003cstrong\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eProduct Features\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eOkoguard cables meet or exceed all recognized industry standards (UL, CSA, NEMA\/ICEA, IEEE).\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003e90°C continuous operating temperature.\u003c\/li\u003e\n\u003cli\u003e130°C emergency rating.\u003c\/li\u003e\n\u003cli\u003e250°C short circuit rating\u003c\/li\u003e\n\u003cli\u003ePasses UL and IEEE 383 and 1202\/FT4 (1\/0 and larger) Vertical Tray Flame Test.\u003c\/li\u003e\n\u003cli\u003eSizes 500 kcmil and larger pass ICEAT-29-520 (210,000 BTU\/hr) Vertical Tray Flame Test.\u003c\/li\u003e\n\u003cli\u003eSizes 1\/0 and larger pass CSA FT4 Vertical Tray Flame Test.\u003c\/li\u003e\n\u003cli\u003eSizes #1 and smaller pass CSA FT1.\u003c\/li\u003e\n\u003cli\u003eExcellent corona resistance.\u003c\/li\u003e\n\u003cli\u003eRadiation resistant.\u003c\/li\u003e\n\u003cli\u003eExceptional resistance to “treeing”.\u003c\/li\u003e\n\u003cli\u003eStress cones not required.\u003c\/li\u003e\n\u003cli\u003eMoisture resistant.\u003c\/li\u003e\n\u003cli\u003eResistant to most oils, acids, and alkalies.\u003c\/li\u003e\n\u003cli\u003eSunlight Resistant.\u003c\/li\u003e\n\u003cli\u003eSizes #6 and #8 AWG are identified as FAA-L-824, Type B 5kV rated.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eSpecification:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003ePart No: 114-24-2243\u003cbr\u003eSize: 500 MCM\u003cbr\u003eInsulation Thickness: 3.56 mm\u003cbr\u003eJacket Thickness: 2.79 mm\u003cbr\u003eAprox OD: 1.29 in\u003cbr\u003eAprox Net Weight lbs\/1000: 2075\u003cbr\u003eAmpacities (2) Conduit in Air: 280\u003cbr\u003eAmpacities (3) Underground Duct: 290\u003cbr\u003eAmpacities (4) Cable Tray: 300\u003cbr\u003e\u003c\/p\u003e","brand":"Nassau National Cable","offers":[{"title":"Default Title","offer_id":44855962894490,"sku":"NNC7095X89","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/okolon-ts-cpe-rhh-rhw2_21_4b30684d-c94a-4d8d-954b-76bfd22e7c66.jpg?v=1759828162","url":"https:\/\/nassaunationalcable.com\/products\/114-24-2243-500-mcm-okoguard-okolon-ts-cpe-type-mv-90-2-4-kv-nonshielded-power-cable","provider":"NassauNationalCable","version":"1.0","type":"link"}