{"product_id":"100-ft-edge8-mtp-trunk-72f-multimode-ge5e572qpnddu100f","title":"100 Ft EDGE8 MTP Trunk 72F multimode GE5E572QPNDDU100F","description":"[pdf] \u003cembed src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/GE5E572QPNDDU100F_03.pdf?v=1698239937\"\u003e [\/pdf]\u003cbr\u003e\n\u003ch3\u003e\n\u003cstrong\u003eAlso Known As:\u003c\/strong\u003e\u003cbr\u003e\n\u003c\/h3\u003e\n\u003cp\u003eEDGE8, MTP Trunk 72F, 50 µm multimode (OM4), 100 ft.EDGE8 is a solution from Corning, which provides pre-terminated optical cabling systems designed for data center applications.\u003cbr\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong data-mce-fragment=\"1\"\u003eAbout:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eEDGE8 MTP trunks provide the backbone of the EDGE8 solution. With 8-fiber pinned MTP connectors on both ends, these trunks are designed to interface with EDGE8 universal modules or adapter panels for parallel optic applications. All MTP trunks are manufactured with Corning CleanAdvantage technology and shipped with strain-relief clips to allow easy tool-less installation.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eSpecifications:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eProduct Number\u003cstrong\u003e:\u003c\/strong\u003e GE5E572QPNDDU100F\u003cbr\u003eFlame Rating\u003cstrong data-mce-fragment=\"1\"\u003e:\u003c\/strong\u003e Plenum (OFNP)\u003cbr\u003eFiber Category\u003cstrong data-mce-fragment=\"1\"\u003e:\u003c\/strong\u003e 50 µm MM (OM4)\u003cbr\u003eCable Assembly Type\u003cstrong data-mce-fragment=\"1\"\u003e:\u003c\/strong\u003e EDGE8 Trunk\u003cbr\u003eCable Type\u003cstrong data-mce-fragment=\"1\"\u003e:\u003c\/strong\u003e Indoor ANSI\/ICEA S-83-596\u003cbr\u003eRoHS\u003cstrong data-mce-fragment=\"1\"\u003e:\u003c\/strong\u003e Free of hazardous substances according to RoHS 2011\/65\/EU\u003cbr data-mce-fragment=\"1\"\u003eApprovals and Listings\u003cstrong data-mce-fragment=\"1\"\u003e:\u003c\/strong\u003e NFPA 262, National Electrical Code (NEC), OFNP, CSA FT-6\u003cbr\u003eTemperature Range, Installation\u003cstrong data-mce-fragment=\"1\"\u003e:\u003c\/strong\u003e -5 °C to 50 °C (23 °F to 122 °F )\u003cbr data-mce-fragment=\"1\"\u003eTemperature Range, Operation\u003cstrong data-mce-fragment=\"1\"\u003e:\u003c\/strong\u003e -10 °C to 60 °C (14 °F to 140 °F )\u003cbr\u003eFiber Count\u003cstrong data-mce-fragment=\"1\"\u003e:\u003c\/strong\u003e 72\u003cbr data-mce-fragment=\"1\"\u003ePolarity\u003cstrong data-mce-fragment=\"1\"\u003e:\u003c\/strong\u003e Universal, TIA-568 Type-B\u003cbr data-mce-fragment=\"1\"\u003eFiber Type\u003cstrong data-mce-fragment=\"1\"\u003e:\u003c\/strong\u003e Multimode\u003cbr\u003eMin. Bend Radius Installation\u003cstrong data-mce-fragment=\"1\"\u003e:\u003c\/strong\u003e 153 mm (6.02 in)\u003cbr data-mce-fragment=\"1\"\u003eMin. Bend Radius Operation\u003cstrong data-mce-fragment=\"1\"\u003e:\u003c\/strong\u003e 51 mm (2.01 in)\u003cbr\u003eFiber Code\u003cstrong data-mce-fragment=\"1\"\u003e:\u003c\/strong\u003e Q\u003cbr data-mce-fragment=\"1\"\u003eFiber Type\u003cstrong data-mce-fragment=\"1\"\u003e:\u003c\/strong\u003e Multimode\u003cbr\u003eInsertion Loss, Max\u003cstrong data-mce-fragment=\"1\"\u003e: \u003c\/strong\u003e0.25 dB\u003cbr data-mce-fragment=\"1\"\u003eBoot Color\u003cstrong data-mce-fragment=\"1\"\u003e:\u003c\/strong\u003e Black\u003cbr data-mce-fragment=\"1\"\u003eConnector Type\u003cstrong data-mce-fragment=\"1\"\u003e:\u003c\/strong\u003e MTP (pinned)\u003cbr data-mce-fragment=\"1\"\u003eFerrule Material\u003cstrong data-mce-fragment=\"1\"\u003e:\u003c\/strong\u003e Composite\u003cbr data-mce-fragment=\"1\"\u003eReflectance\u003cstrong data-mce-fragment=\"1\"\u003e:\u003c\/strong\u003e \u0026lt; -20 dB\u003cbr\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eCommon Applications:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cspan data-mce-fragment=\"1\"\u003e• \u003c\/span\u003e\u003c\/strong\u003eData Centers\u003cbr\u003e\u003cstrong data-mce-fragment=\"1\"\u003e\u003cspan data-mce-fragment=\"1\"\u003e• \u003c\/span\u003e\u003c\/strong\u003eTelecommunications Networks\u003cbr\u003e\u003cstrong data-mce-fragment=\"1\"\u003e\u003cspan data-mce-fragment=\"1\"\u003e• \u003c\/span\u003e\u003c\/strong\u003eFTTx (Fiber to the x)\u003cbr\u003e\u003cstrong data-mce-fragment=\"1\"\u003e\u003cspan data-mce-fragment=\"1\"\u003e• \u003c\/span\u003e\u003c\/strong\u003eHigh-Density Networks\u003cbr\u003e\u003cstrong data-mce-fragment=\"1\"\u003e\u003cspan data-mce-fragment=\"1\"\u003e• \u003c\/span\u003e\u003c\/strong\u003eCable Television (CATV) Networks\u003cbr\u003e\u003cstrong data-mce-fragment=\"1\"\u003e\u003cspan data-mce-fragment=\"1\"\u003e• \u003c\/span\u003e\u003c\/strong\u003eLocal Area Networks (LANs)\u003cbr\u003e\u003cstrong data-mce-fragment=\"1\"\u003e\u003cspan data-mce-fragment=\"1\"\u003e• \u003c\/span\u003e\u003c\/strong\u003eMeasurement and Testing\u003cbr\u003e\u003cstrong data-mce-fragment=\"1\"\u003e\u003cspan data-mce-fragment=\"1\"\u003e• \u003c\/span\u003e\u003c\/strong\u003eRiser Applications\u003cbr\u003e\u003cstrong data-mce-fragment=\"1\"\u003e\u003cspan data-mce-fragment=\"1\"\u003e• \u003c\/span\u003e\u003c\/strong\u003eMedical Imaging and Sensors\u003cbr\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eFeatures:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003e• \u003c\/strong\u003eState-of-the-art manufacturing processes: Advanced technology results in unsurpassed product consistency and quality\u003c\/p\u003e\n\u003cdiv class=\"featureBenefitElement\" bis_skin_checked=\"1\"\u003e\n\u003cdiv class=\"featureBenefitElement__feature\" bis_skin_checked=\"1\"\u003e\n\u003cstrong data-mce-fragment=\"1\"\u003e• \u003c\/strong\u003eGlobal operations: Mitigates trade barriers or supply disruptions\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"featureBenefitElement\" bis_skin_checked=\"1\"\u003e\n\u003cdiv class=\"featureBenefitElement__feature\" bis_skin_checked=\"1\"\u003e\n\u003cbr\u003e\u003cstrong data-mce-fragment=\"1\"\u003e• \u003c\/strong\u003eFlexible design options: Choice of materials for strength elements and fiber properties for various application requirements\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"featureBenefitElement\" bis_skin_checked=\"1\"\u003e\n\u003cdiv class=\"featureBenefitElement__feature\" bis_skin_checked=\"1\"\u003e\n\u003cbr\u003e\u003cstrong data-mce-fragment=\"1\"\u003e• \u003c\/strong\u003eSuperior performance testing: Each termination is tested to ensure the highest network performance\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"featureBenefitElement\" bis_skin_checked=\"1\"\u003e\n\u003ch3 class=\"featureBenefitElement__feature\" bis_skin_checked=\"1\"\u003e\n\u003cstrong\u003e\u003c\/strong\u003e\u003cstrong\u003e\u003cbr data-mce-fragment=\"1\"\u003e\u003c\/strong\u003e\u003cstrong style=\"font-size: 0.875rem;\" data-mce-style=\"font-size: 0.875rem;\"\u003eStandards:\u003c\/strong\u003e\n\u003c\/h3\u003e\n\u003c\/div\u003e\n\u003cp\u003e\u003cbr\u003e\u003cspan data-mce-fragment=\"1\"\u003e• \u003c\/span\u003eConnector Assembly Type\u003cstrong data-mce-fragment=\"1\"\u003e:\u003c\/strong\u003e MTP to MTP \u003cbr\u003e\u003cspan data-mce-fragment=\"1\"\u003e• Fiber Standards\u003cstrong data-mce-fragment=\"1\"\u003e:\u003c\/strong\u003e TIA\/EIA-492AAAC-A, Tested with minEMBc method to TIA\/EIA-455-220, IEC 60793-2-10 Type A1a.2 Ed.2.0, IEC 60793-1-49 Ed.2.0, ITU-T G.651, ISO\/IEC 11801 Ed.2.2 Cat. OM3\u003cbr\u003e• Pulling grip\u003cstrong data-mce-fragment=\"1\"\u003e:\u003c\/strong\u003e Yes\u003cbr data-mce-fragment=\"1\"\u003e• Tensile Strength\u003cstrong data-mce-fragment=\"1\"\u003e:\u003c\/strong\u003e 440 N (98.92 lbf)\u003cbr data-mce-fragment=\"1\"\u003e• Grip Outer Diameter\u003cstrong data-mce-fragment=\"1\"\u003e:\u003c\/strong\u003e 56 mm (2.2 in)\u003cbr\u003e• Min. Duct Size Diameter\u003cstrong data-mce-fragment=\"1\"\u003e:\u003c\/strong\u003e 89 mm (3.5 in)\u003cbr\u003e• Furcation Type \u003cstrong data-mce-fragment=\"1\"\u003e:\u003c\/strong\u003e EDGE Size 2, 20 mm x 20 mm x 108.6 mm\u003cbr data-mce-fragment=\"1\"\u003e• Leg Color\u003cstrong data-mce-fragment=\"1\"\u003e:\u003c\/strong\u003e Aqua\u003cbr data-mce-fragment=\"1\"\u003e• Leg Diameter\u003cstrong data-mce-fragment=\"1\"\u003e:\u003c\/strong\u003e 2 mm (0.08 in)\u003cbr data-mce-fragment=\"1\"\u003e• Leg Count\u003cstrong data-mce-fragment=\"1\"\u003e:\u003c\/strong\u003e 9\u003cbr data-mce-fragment=\"1\"\u003e• Leg Length\u003cstrong data-mce-fragment=\"1\"\u003e:\u003c\/strong\u003e 840 mm -0 \/ +76mm (33.07 in -0 \/ +2.99in)\u003c\/span\u003e\u003cbr\u003e\u003cbr\u003e\u003cspan data-mce-fragment=\"1\"\u003e\u003c\/span\u003e\u003cstrong\u003eConstruction: \u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003e• \u003c\/strong\u003eFiber Core: At the heart of the trunk cable, there are 72 individual fibers, each with a core diameter of 50 micrometers.\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong data-mce-fragment=\"1\"\u003e•\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003e\u003c\/strong\u003eCladding: Surrounding each fiber core is a layer of cladding, which ensures that the light traveling through the core remains inside by total internal reflection.\u003cbr\u003e\u003cbr\u003e\u003cstrong data-mce-fragment=\"1\"\u003e•\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003e\u003c\/strong\u003eProtective Coating: Each fiber (core + cladding) is coated with a protective layer to provide mechanical protection and ensure durability.\u003cbr\u003e\u003cstrong data-mce-fragment=\"1\"\u003e\u003cbr\u003e•\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003e\u003c\/strong\u003eStrength Members: Surrounding the buffered fibers, there are often strength members (like aramid yarn) to add tensile strength to the cable and protect it from physical stresses.\u003cbr data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003e\u003cbr\u003e•\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003e\u003c\/strong\u003eMTP Connectors: At both ends of the trunk cable, the fibers are terminated with MTP connectors. In this case, each connector would handle all 72 fibers.\u003cbr data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003e\u003cbr\u003e•\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003e\u003c\/strong\u003eLabeling and Serialization: Typically, these trunk cables will be labeled for identification and traceability, and to provide key information such as fiber type, count, and length.\u003cbr\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003e\u003c\/strong\u003e\u003c\/h3\u003e\n\u003ch3\u003e\u003cstrong\u003e\u003c\/strong\u003e\u003c\/h3\u003e","brand":"Corning","offers":[{"title":"Default Title","offer_id":44033413218458,"sku":"GE5E572QPNDDU100F","price":7999.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/03_670a1c98-5522-4e6a-86e3-e4c5db4822ad.png?v=1762982854","url":"https:\/\/nassaunationalcable.com\/products\/100-ft-edge8-mtp-trunk-72f-multimode-ge5e572qpnddu100f","provider":"NassauNationalCable","version":"1.0","type":"link"}