{"product_id":"1-0-awg-hvteck-copper-220-mil-nlepr-cb-aia-15kv-133-il-red-pvc-jacket-csa-1","title":"1\/0 AWG HVTECK Copper 220 mil NLEPR CB AIA 15KV 133% IL Red PVC Jacket CSA","description":"\u003cp\u003e[short] [pdf] \u003cembed src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/2000_2.pdf?v=1756369378\"\u003e [\/pdf]\u003c\/embed\u003e\u003c\/p\u003e\n\u003ch2\u003e\u003cspan data-sheets-root=\"1\"\u003e1\/0 AWG HVTECK Copper 220 mil NLEPR CB AIA 15KV 133% IL Red PVC Jacket CSA\u003c\/span\u003e\u003c\/h2\u003e\n\u003ch3\u003eApplication\u003cstrong\u003e:\u003c\/strong\u003e\n\u003c\/h3\u003e\n\u003cp\u003eThe 15kV HVTECK is a CSA armoured cable for industrial and commercial medium voltage applications. Rated FT4, -40°C, Hazardous Locations (HL). These cables are capable of operating continuously at the conductor temperature not in excess of 105°C for normal operation, 140°C for emergency overload, and 250°C for short circuit conditions. Rated for 1000 lbs \/FT maximum sidewall pressure. These cables feature sunlight and moisture resistance, exceptional corona resistance, resistance to most chemical soils and acids and are flame retardant Single Conductor, 220 Mils No Lead Ethylene Propylene Rubber (NL-EPR), 133% Insulation Level, Tape Shield, Polyvinyl Chloride (PVC) Inner Jacket, Aluminum Interlocked Armour (AIA), Polyvinyl Chloride (PVC) Jacket\u003c\/p\u003e\n\u003ch3\u003eAlso known as:\u003cbr\u003e\n\u003c\/h3\u003e\n\u003cdiv class=\"flex max-w-full flex-col grow\"\u003e\n\u003cdiv data-message-model-slug=\"gpt-4o-mini\" class=\"min-h-8 text-message relative flex w-full flex-col items-end gap-2 text-start break-words whitespace-normal [.text-message+\u0026amp;]:mt-5\" dir=\"auto\" data-message-id=\"8af04988-ab09-44ed-9c7d-0f0aa8dff7d4\" data-message-author-role=\"assistant\"\u003e\n\u003cdiv class=\"flex w-full flex-col gap-1 empty:hidden first:pt-[3px]\"\u003e\n\u003cdiv class=\"markdown prose dark:prose-invert w-full break-words light markdown-new-styling\"\u003e\n\u003cp data-start=\"177\" data-end=\"251\"\u003e1\/0 AWG HVTECK Copper 1\/C 220 mil NLEPR TS AIA 15kV 100% IL Red PVC Jacket CSA HVTECK Copper 1\/C 220 mil TRXLPE TS AIA 15kV 133% IL Red PVC Jacket CSA 1\/0 AWG HVTECK Copper 1\/C 220 mil XLPE TS AIA 15kV 133% IL Red PVC Jacket CSA 1\/0 AWG HVTECK Copper 1\/C 220 mil EPR TS AIA 15kV 133% IL Red PVC Jacket CSA HVTECK Copper 1\/C 220 mil NLEPR TS AIA 20kV 133% IL Red PVC Jacket CSA 1\/0 AWG HVTECK Copper 1\/C 220 mil TRXLPE TS AIA 20kV 133% IL Red PVC Jacket CSA 1\/0 AWG HVTECK Copper 1\/C 220 mil XLPE TS AIA 20kV 100% IL Red PVC Jacket CSA\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"mt-3 w-full empty:hidden\"\u003e\n\u003cdiv class=\"text-center\"\u003e\n\u003cdiv\u003e\n\u003cdiv class=\"inline-flex border border-gray-100 dark:border-gray-700 rounded-xl\"\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003ch3\u003eConstruction:\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eConductor:\u003cbr\u003e\u003c\/strong\u003eClass B compressed stranded bare copper per ASTM B3 and ASTM B8\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003eConductor Shield:\u003cbr\u003e\u003c\/strong\u003eSemi-conducting cross-linked copolymer\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eInsulation\u003c\/strong\u003e:\u003cbr\u003e220 Mils No Lead Ethylene Propylene Rubber (NL-EPR) 133% insulation level\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003eInsulation Shield: \u003cbr\u003e\u003c\/strong\u003eStrippable semi-conducting cross-linked copolymer\u003cbr\u003e\u003cstrong\u003e\u003cbr\u003e Copper Tape Shield:\u003cbr\u003e\u003c\/strong\u003eHelically wrapped 5 mil copper tape with 25% overlap\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003eInner Jacket:\u003cbr\u003e\u003c\/strong\u003ePVC inner jacket\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eArmour:\u003c\/strong\u003e\u003cbr\u003eAluminum Interlocked Armour (AIA))\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eOverall Jacket:\u003c\/strong\u003e\u003cbr\u003eRed Polyvinyl Chloride (PVC) Jacket\u003cbr\u003e\u003c\/p\u003e\n\u003ch3\u003eStandards:\u003c\/h3\u003e\n\u003cp\u003e• ASTM B3 Soft or Annealed Copper Wire\u003cbr\u003e• ASTM B8 Concentric-Lay-Stranded Copper Conductors\u003cbr\u003e• ASTM B33 Standard Specification for Tin-Coated Soft or Annealed Copper Wire\u003cbr\u003e• CSA C22.2 No. 174 Cables in Hazardous Locations\u003cbr\u003e• CSA C22.2 No. 2556 \u0026amp; No. 0.3 Wire and Cable Test Methods\u003cbr\u003e• CSA C68.10 Shielded Power Cables for Commercial and Industrial Applications - 5 to 46 KV\u003cbr\u003e• CSA C68.3 Shielded \u0026amp; Concentric Neutral Power Cable - 5 to 46 kV\u003cbr\u003e• CSA LTGG [-40°C] - as per C68.10 - for Cold Bend and Impact rating\u003cbr\u003e• CSA HL - for Hazardous Locations rating\u003cbr\u003e• CSA SUN RES - for Sunlight Resistant rating\u003cbr\u003e• ICEA S-93-639 (NEMA WC 74) 5-46 KV Shielded Power Cable\u003cbr\u003e• ICEA T-29-520 Flame Test (210,000 BTU\/Hr)\u003cbr\u003e• IEEE 383 Flame Test (70,000 btu)\u003cbr\u003e• IEEE 1202 FT4 Flame Test (70,000) BTU\/hr Vertical Tray Test (1\/0 and Larger)\u003c\/p\u003e\n\u003ch3\u003eSpecification:\u003c\/h3\u003e\n\u003cp class=\"MsoNormal\"\u003e• \u003cstrong\u003eSize:\u003c\/strong\u003e 1\/0 AWG\u003cbr\u003e• \u003cstrong\u003eNumber of Strands:  \u003c\/strong\u003e19\u003cbr\u003e• \u003cstrong\u003eDiameter Over Conductor (inch):\u003c\/strong\u003e  0.361\u003cbr\u003e• \u003cstrong\u003eDiameter Over Insulation (inch): \u003c\/strong\u003e 0.839\u003cbr\u003e• \u003cstrong\u003eInsul. Thickness mil: \u003c\/strong\u003e 220\u003cbr\u003e• \u003cstrong\u003eDiameter Over Insulation Shield (inch):  \u003c\/strong\u003e0.899\u003cbr\u003e• \u003cstrong\u003eInner Jacket Thickness (mil):\u003c\/strong\u003e  80\u003cbr\u003e• \u003cstrong\u003eDiameter Over Armor (inch): \u003c\/strong\u003e 1.411\u003cbr\u003e• \u003cstrong\u003eOverall Jacket Thickness mil :\u003c\/strong\u003e 50\u003cbr\u003e• \u003cstrong\u003eApprox. OD inch :\u003c\/strong\u003e 1.511\u003cbr\u003e• \u003cstrong\u003eCopper Weight lb\/1000ft:\u003c\/strong\u003e 343\u003cbr\u003e• \u003cstrong\u003eApprox. Weight (Lbs\/1000'Ft): \u003c\/strong\u003e 1099\u003cbr\u003e• \u003cstrong\u003eDC Resistance @ 25°C Ω \/1000ft:\u003c\/strong\u003e  0.102\u003cbr\u003e• \u003cstrong\u003eAC Resistance @ 90°Ω \/1000ft:\u003c\/strong\u003e   0.128\u003cbr\u003e• \u003cstrong\u003eAllowable Ampacity In Air 90°C Amp: \u003c\/strong\u003e278\u003cbr\u003e• \u003cstrong\u003eAllowable Ampacity Directly Buried 90°C Amp:\u003c\/strong\u003e 275\u003cbr\u003e\u003c\/p\u003e","brand":"Nassau National Cable","offers":[{"title":"Default Title","offer_id":55761822974321,"sku":"NNC528693","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/500_3_efa147ba-7c5a-4357-ad4a-c98f2241cab0.png?v=1756368973","url":"https:\/\/nassaunationalcable.com\/products\/1-0-awg-hvteck-copper-220-mil-nlepr-cb-aia-15kv-133-il-red-pvc-jacket-csa-1","provider":"NassauNationalCable","version":"1.0","type":"link"}