{"product_id":"1-0-awg-3c-type-mv-105-copper-35kv-nlepr-insulation-133-il-armor-x-orange-pvc-jacket","title":"1\/0 AWG 3C Type MV-105 Copper 35kV NLEPR Insulation 133% IL ARMOR-X Orange PVC Jacket","description":"\u003ch2\u003e\n\u003cspan\u003e1\/0 AWG 3C Type MV-105 Copper 35kV NLEPR Insulation 133% IL ARMOR-X Orange PVC Jacket\u003c\/span\u003e\u003cspan\u003e\u003c\/span\u003e\n\u003c\/h2\u003e\n\u003ch3\u003e\u003cspan\u003eApplication:\u003c\/span\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cspan\u003eSouthwire’s 35KV ARMOR-X are armored cables for use in wet and dry areas, conduits, ducts, troughs, trays, direct burial, and where superior electrical properties are desired. These cables are capable of operating continuously at the conductor temperature not in excess of 105°C for normal operation, 140°C for emergency overload, 250°C for short circuit conditions, and -50°C for cold bend. For uses in Class I, II, and III, Division 1 and 2 hazardous locations per NEC Article 501, 502, and 503. Type MV-105 Three Conductor Copper, 420 Mils No Lead Ethylene Propylene Rubber (NL-EPR) 133% Insulation Level, Tape Shield, Continuous Corrugated Welded Armor - ARMOR-X, Polyvinyl Chloride (PVC) Jacket. Silicone Free.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cspan\u003eAlso known as:\u003c\/span\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cspan\u003e1\/0 AWG 3C 35kV Medium Voltage Cable, 1\/0 AWG 3C 35kV MV-105 Cable,1\/0 AWG 3C 3-Conductor 35kV Copper Cable, 1\/0 AWG 3C 35kV Armored Power Cable, 1\/0 AWG 3C  ARMOR-X Cable, 1\/0 AWG 3C 133% Insulation Level Cable, 1\/0-3C NL-EPR Insulated Cable,  1\/0-3C Copper Tape Shielded Cable, 1\/0-3C  Continuous Corrugated Welded Armor Cable,  1\/0-3C CCW Armored Cable, 1\/0-3C 35kV Direct Burial Cable, 1\/0-3C  MV-105 Tray Cable, MC-HL Medium Voltage Cable, 1\/0-3C Hazardous Location Power Cable, 1\/0-3C Orange PVC Jacketed MV Cable.\u003cbr\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cspan\u003eConstructions:\u003c\/span\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eConductor: \u003c\/strong\u003eClass B compressed stranded bare copper per ASTM B3 and B8 (Tinned Copper per ASTM B33 optional)\u003cbr\u003e\u003cstrong\u003eConductor Shield: \u003c\/strong\u003eSemi-conducting cross-linked copolymer\u003cbr\u003e\u003cstrong\u003eInsulation: \u003c\/strong\u003e420 Mils No Lead Ethylene Propylene Rubber (NL-EPR) 133% Insulation Level\u003cbr\u003e\u003cstrong\u003eInsulation Shield:\u003c\/strong\u003e Strippable semi-conducting cross-linked copolymer\u003cbr\u003e\u003cstrong\u003eCopper Tape Shield: \u003c\/strong\u003eHelically wrapped 5 mil copper tape with 25% overlap\u003cbr\u003e\u003cstrong\u003eGrounding Conductor:\u003c\/strong\u003e Class B compressed stranded bare copper ground per ASTM B3 and B8 (Tinned Copper per ASTM B33 optional)\u003cbr\u003e\u003cstrong\u003eFiller: \u003c\/strong\u003eWax paper filler\u003cbr\u003e\u003cstrong\u003eBinder: \u003c\/strong\u003ePolypropylene tape\u003cbr\u003e\u003cstrong\u003eArmor:\u003c\/strong\u003e ARMOR-X Continuous Corrugated Welded Armor\u003cbr\u003e\u003cstrong\u003eOverall Jacket:\u003c\/strong\u003e Polyvinyl Chloride (PVC) \u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003eStandards :\u003c\/h3\u003e\n\u003cp\u003e• ASTM B3 Soft or Annealed Copper Wire\u003cbr\u003e• ASTM B8 Concentric-Lay-Stranded Copper Conductors\u003cbr\u003e• ASTM B33 Standard Specification for Tin-Coated Soft or Annealed Copper Wire\u003cbr\u003e• UL 1072 Medium-Voltage Power Cables\u003cbr\u003e• UL 1685 FT4 Vertical-Tray Fire Propagation and Smoke Release Test\u003cbr\u003e• ICEA S-93-639 (NEMA WC 74) 5-46 KV Shielded Power Cable\u003cbr\u003e• IEEE 1202 FT4 Flame Test (70,000) BTU\/hr Vertical Tray Test\u003cbr\u003e\u003c\/p\u003e\n\u003ch3\u003eSpecifications: \u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eConductor size\u003c\/strong\u003e:  1\/0 AWG\u003cbr\u003e\u003cstrong\u003eNo of Strands\u003c\/strong\u003e:  19 \u003cbr\u003e\u003cstrong\u003eDiameter Over Conductor: \u003c\/strong\u003e0.361 inch\u003cbr\u003e\u003cstrong\u003eDiameter Over Insulation:\u003c\/strong\u003e  1.240 inch\u003cbr\u003e\u003cstrong\u003eDiameter Over Insulation Shield:\u003c\/strong\u003e 1.300 inch\u003cbr\u003e\u003cstrong\u003eGround\u003c\/strong\u003e:  1x4 AWG\u003cbr\u003e\u003cstrong\u003eDiameter Over armor: \u003c\/strong\u003e 3.540 inch\u003cbr\u003e\u003cstrong\u003eJacket Thickness:\u003c\/strong\u003e 85 mil\u003cbr\u003e\u003cstrong\u003eApprox. OD:\u003c\/strong\u003e  3.710 inch\u003cbr\u003e\u003cstrong\u003eCopper Weight (lb\/1000ft\u003c\/strong\u003e): 1431\u003cbr\u003e\u003cstrong\u003eApprox. Weight  (lb\/1000ft\u003c\/strong\u003e): 5481\u003cbr\u003e\u003cstrong\u003eMax Pull Tension (lb)\u003c\/strong\u003e: 2534\u003cbr\u003e\u003cstrong\u003eMin Bending Radius\u003c\/strong\u003e: 25.9 inch\u003c\/p\u003e","brand":"Nassau National Cable","offers":[{"title":"Default Title","offer_id":64604307128689,"sku":null,"price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/Untitleddesign_8258265a-fada-42f3-8ad5-383f79a21ca7.png?v=1789461521","url":"https:\/\/nassaunationalcable.com\/products\/1-0-awg-3c-type-mv-105-copper-35kv-nlepr-insulation-133-il-armor-x-orange-pvc-jacket","provider":"NassauNationalCable","version":"1.0","type":"link"}