{"product_id":"type-mv-105-interlocked-armored-power-cable-15kv-pvc-jacket","title":"Type MV-105 Interlocked Armored Power Cable 15kV PVC Jacket","description":"\u003cp\u003e [pdf] \u003cembed src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/CatalogG12_1.pdf?v=1729681491\"\u003e [\/pdf]\u003c\/embed\u003e\u003c\/p\u003e\n\u003cstyle type=\"text\/css\"\u003e\u003c!--td {border: 1px solid #cccccc;}br {mso-data-placement:same-cell;}--\u003e\u003c\/style\u003e\n\u003ch2\u003e\u003cstrong\u003e\u003cspan data-sheets-root=\"1\"\u003eType MV-105 Interlocked Armored Power Cable 15kV PVC Jacket\u003c\/span\u003e\u003c\/strong\u003e\u003c\/h2\u003e\n\u003ch3\u003e\u003cstrong\u003eDescription:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003e•  \u003c\/strong\u003e3 copper conductors\u003cbr\u003e\u003cstrong\u003e•  \u003c\/strong\u003eThermosetting conductor shield\u003cbr\u003e\u003cstrong\u003e•  \u003c\/strong\u003eEPR insulation\u003cbr\u003e\u003cstrong\u003e•  \u003c\/strong\u003eThermosetting insulation shield\u003cbr\u003e\u003cstrong\u003e• \u003c\/strong\u003e Tape shield\u003cbr\u003e\u003cstrong\u003e•  \u003c\/strong\u003eCopper ground wire\u003cbr\u003e\u003cstrong\u003e•  \u003c\/strong\u003eAluminum armor\u003cbr\u003e\u003cstrong\u003e•  \u003c\/strong\u003ePVC Jacket\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eApplication:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003e• \u003c\/strong\u003eAerial installations\u003cbr\u003e\u003cstrong\u003e• \u003c\/strong\u003eOpen trays\u003cbr\u003e\u003cstrong\u003e• \u003c\/strong\u003eDirect burial \u003cbr\u003e\u003cstrong\u003e• \u003c\/strong\u003eTroughs or continuous rigid\u003cbr\u003e\u003cstrong\u003e• \u003c\/strong\u003eMetal racks cable supports\u003cbr\u003eThese cables are capable of operating continuously at maximum conductor temperature of 105°C for normal operation, 140°C for emergency overload conditions, and 250°C for short circuit conditions, and are rated at 15,000V, 133% insulation level (ungrounded system).\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eAlso Known As:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eMV-105 15kV armored cable specs, Interlocked armor MV-105 power cable, 15kV MV-105 PVC jacket cable, MV-105 15kV cable with armor, MV-105 medium voltage power cable, 15kV PVC jacketed power cable, MV-105 interlocked armored cable price, 15kV MV-105 cable voltage rating, MV-105 armored power cable installation, 15kV MV-105 copper conductor cable\u003c\/p\u003e\n\u003ch4\u003e\u003cstrong\u003eStandards:\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cp\u003eManufactured and tested in accordance with the latest revisions of ICEA Pub. No. S-68-516, NEMA Pub. No. WC8, AEIC No. 6, and UL 1072. Passes IEEE 1202 (70,000 Btu\/hr) and ICEA T-29-520 (210,000 Btu\/hr) vertical cable tray flame tests.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eConstruction:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003e• Conductor: \u003c\/strong\u003eThe conductor shall be Class B compressed concentric stranded bare copper in accordance with ASTM B3 and B8 and ICEA Part 2, Section 2.1 and 2.5.\u003cbr\u003e\u003cstrong\u003e• Conductor \u003c\/strong\u003e\u003cstrong\u003eShield: \u003c\/strong\u003eThe conductor shall be shielded with an extruded semi-conducting thermosetting polymeric layer, which shall be firmly bonded to the insulation. The thickness shall be in accordance with the referenced standards.\u003cbr\u003e\u003cstrong\u003e• Insulation:\u003c\/strong\u003e The insulation shall be EPR (ethylene propylene rubber) meeting the requirements of the referenced standards. The average thickness shall be 0.220\" and the minimum spot thickness shall be not less than 90% of the average thickness.\u003cbr\u003e\u003cstrong\u003e• Insulation \u003c\/strong\u003e\u003cstrong\u003eShield: \u003c\/strong\u003eThe insulation shall be shielded with an extruded semi-conducting thermosetting polymeric layer which shall be identified as semi-conducting. Over this layer shall be applied helically-wrapped 5-mil copper tape.\u003cbr\u003e\u003cstrong\u003e• Grounding \u003c\/strong\u003e\u003cstrong\u003eConductor: \u003c\/strong\u003eThe ground conductor shall be Class B compressed concentric stranded bare copper in accordance with ASTM B3 and B8.\u003cbr\u003e\u003cstrong\u003e• Assembly: \u003c\/strong\u003eThe insulated and shielded power conductors shall be cabled round with fillers and with a grounding conductor in one outer interstice and covered with a binder tape.\u003cbr\u003e\u003cstrong\u003e• Armor:\u003c\/strong\u003e A single strip of interlocked armor of aluminum shall be applied over the assembly.\u003cbr\u003e\u003cstrong\u003e• Jacket: \u003c\/strong\u003eThe cable shall be covered with a red PVC jacket conforming to the requirements specified for polyvinyl chloride in ICEA. The average thickness shall be in accordance with the referenced standards and the minimum spot thickness shall be not less than 80% of the average thickness. The jacket will be sunlight resistant and will meet the requirements of the IEEE 1202 (70,000 Btu\/hr) and ICEA T-29-520 (210,000 Btu\/hr) vertical cable tray flame tests. Optional non-halogen jacket is available.\u003cbr\u003e\u003cstrong\u003e• Identification:\u003c\/strong\u003e Manufacturer's identification shall be printed on the jacket\u003cbr\u003e\u003cstrong\u003e• Available \u003c\/strong\u003e\u003cstrong\u003eAlternatives: \u003c\/strong\u003eIn order to meet the IEEE 383 vertical tray flame test modified to 210,000 Btu, a special PVC jacket and binder tape beneath the armor are used.\u003cbr\u003e\u003c\/p\u003e\n\u003ch4\u003e\u003cstrong\u003eScope:\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cp\u003eThis specification covers three conductor EPR (ethylene propylene rubber) insulated, shielded, interlock armored, thermoplastic jacketed power cables with grounding conductor for use in aerial installations, metal racks, open trays, troughs, or continuous rigid cable supports. These cables are capable of operating continuously at a temperature of 105°C for normal operations, 140°C for emergency overload conditions, and 250°C for short circuit conditions, and are rated at 15,000V, 133% insulation level (ungrounded system).\u003c\/p\u003e","brand":"Nassau National Cable","offers":[{"title":"Default Title","offer_id":51648569966961,"sku":"","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/15_4eb325e5-3685-4b09-90b8-f2c297561f10.png?v=1763008225","url":"https:\/\/nassaunationalcable.com\/en-ca\/products\/type-mv-105-interlocked-armored-power-cable-15kv-pvc-jacket","provider":"NassauNationalCable","version":"1.0","type":"link"}