{"product_id":"triplex-aluminum-conductor-underground-direct-burial-1350-series-600v-urd-cable","title":"Triplex Aluminum Conductor Underground Direct Burial 1350 Series 600V URD Cable","description":"\u003cp\u003e[pdf] \u003cembed type=\"application\/pdf\" height=\"\" width=\"\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/AL_URD.pdf?v=1698446562\"\u003e [\/pdf]\u003c\/embed\u003e\u003c\/p\u003e\n\u003ch2\u003eTriplex Aluminum Conductor Underground Direct Burial 1350 Series 600V URD Cable\u003c\/h2\u003e\n\u003ch3\u003e\u003cspan style=\"font-weight: 400;\"\u003eApplications:\u003c\/span\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cspan style=\"font-weight: 400;\"\u003eThe Aluminum 600V URD is designed to serve in the secondary distribution circuits for power. In these secondary circuits, the electrical cable is installed in duct or direct burial applications. Due to its versatility, conductor strength, and insulation integrity, it works well for these outdoor applications. It is also used in wet and dry places since the electrical cable has a maximum operating temperature of 90\u003c\/span\u003e\u003cspan style=\"font-weight: 400;\"\u003e°\u003c\/span\u003e\u003cspan style=\"font-weight: 400;\"\u003eC. The \u003cspan\u003etriplex wire for sale \u003c\/span\u003eis also designed to provide an option of pre-pulling into ducts.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cspan style=\"font-weight: 400;\"\u003eAlso Known As:\u003c\/span\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cspan style=\"font-weight: 400;\"\u003eAluminum urd cable, urd direct burial cable, \u003cspan\u003ethree conductor cable, tri plex wire, triplex cable, triplex aluminum underground wire, 3 conductor power cable, aluminum triplex, underground triplex, triplex underground cable, triplex wire underground, direct burial triplex, triplex conductor, \u003c\/span\u003edirect burial electrical cable, direct burial power cable, aluminum direct burial cable.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cspan style=\"font-weight: 400;\"\u003eStandards:\u003c\/span\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli style=\"font-weight: 400;\"\u003e\n\u003cp\u003e\u003cspan style=\"font-weight: 400;\"\u003eASTM B-230\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli style=\"font-weight: 400;\"\u003e\n\u003cp\u003e\u003cspan style=\"font-weight: 400;\"\u003eASTM B-231\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli style=\"font-weight: 400;\"\u003e\n\u003cp\u003e\u003cspan style=\"font-weight: 400;\"\u003eASTM B-609\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli style=\"font-weight: 400;\"\u003e\n\u003cp\u003e\u003cspan style=\"font-weight: 400;\"\u003eASTM B-901\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli style=\"font-weight: 400;\"\u003e\n\u003cp\u003e\u003cspan style=\"font-weight: 400;\"\u003eICEA S-105-692\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli style=\"font-weight: 400;\"\u003e\n\u003cp\u003e\u003cspan style=\"font-weight: 400;\"\u003eJ-C- 30B Federal Specification\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli style=\"font-weight: 400;\"\u003e\n\u003cp\u003e\u003cspan style=\"font-weight: 400;\"\u003eRUS accepted\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cspan style=\"font-weight: 400;\"\u003eConstruction\u003c\/span\u003e\u003c\/h3\u003e\n\u003ch4\u003e\u003cspan style=\"font-weight: 400;\"\u003eConductors:\u003c\/span\u003e\u003c\/h4\u003e\n\u003cp\u003e\u003cspan style=\"font-weight: 400;\"\u003eAluminum conductors used for this cable are designed in either concentric strand or in compressed series. The advantage with a compressed conductor is the reduced bulkiness. Compressed conductors are also stronger and tougher; the stranded conductors are highly flexible and tend to have lower electrical resistance. Stranded conductors therefore reduce power loss and are also easier to use in applications where flexibility is vital. Aluminum 600 V URD cable \u003c\/span\u003e\u003cspan style=\"font-weight: 400;\"\u003ehas three aluminum conductors.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch4\u003e\u003cspan style=\"font-weight: 400;\"\u003eInsulation:\u003c\/span\u003e\u003c\/h4\u003e\n\u003cp\u003e\u003cspan style=\"font-weight: 400;\"\u003eVersatile insulation system made of cross linked black polyethylene material helps to secure the cable conductors. This insulation is water tight, repulsive to corrosive substances, resistant to oil, heat and flame. Cross linking a polyethylene helps to achieve an excellent strength that makes the material suitable for covering this cable used in harsh conditions like direct burial installation.\u003c\/span\u003e\u003c\/p\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cp\u003e[\/short]\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTriplex Aluminum Conductor Direct Burial 1350 Series 600V URD\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eIt is a 600V rated cable with three aluminum conductors. Being suitable for use in direct burial, triplex aluminum conductor cable has outstanding properties to help it cope with the nature of its demanding applications. Here are some of the properties:\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eConductors:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eAluminum 600V URD cable is made of two types of conductors: either concentric strand or compressed series of aluminum conductors. The stranded wire is more flexible and appropriate for applications that have several bends. While the compressed conductor is suitable for systems where tough cables are needed. These conductors are coupled together to improve cable integrity and the surface printed for identification purposes. Its neutral conductor always has a yellow strip.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eInsulation:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eAluminum 600V URD cable has a cross linked polyethylene (XLP) insulation. Cross linking a thermosetting like polyethylene helps to improve its strength and versatility. For this cable to tolerate and overcome the odds that come with direct burial, it needs a reliable insulation. An insulation which is resistant to moisture, chemicals, oil, tear and abrasions.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eApplications:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eAluminum 600V URD is appropriate to use in establishing secondary power distribution circuits. These circuits wired using the cable can be installed either in duct or directly buried in the ground. Due to its versatility and enduring insulation, the cable works well in these applications. Even in adverse temperatures, Aluminum 600 URD triplex cable serves. It has a maximum operation temperature of 90 degrees Celsius and can work in both wet and dry places. It has a voltage power rating of 600 volts, good for medium size loads. The cable is also designed with an option, provision of pre-pulling into duct.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eStandard Approvals:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e• ASTM B-230\u003cbr\u003e• ASTM B-231\u003cbr\u003e• ASTM B-609\u003cbr\u003e• ASTM B-901\u003cbr\u003e• ICEA S-105-692\u003cbr\u003e• J-C- 30B Federal Specification\u003cbr\u003e• RUS accepted\u003c\/p\u003e\n\u003cp style=\"text-align: left;\"\u003e\u003cstrong\u003eQuestion and Answer:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp style=\"text-align: center;\"\u003e\u003cstrong\u003e\u003cspan style=\"text-decoration: underline;\"\u003eFrequently Asked Questions - Triplex Aluminum URD\u003c\/span\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cspan style=\"text-decoration: underline;\"\u003eCan the Triplex Aluminum URDcables be buried directly in the ground? \u003c\/span\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eYes, Triplex Aluminum URD cables can be buried directly in the ground. It can also be installed in an underground duct.It has been developed in such a way that it can be used in congested areas and is easy to install. Since it is low smoke and flame cables, it can be used both in wet and dry places.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cspan style=\"text-decoration: underline;\"\u003eIs TriplexAluminium URD better than copper wires?\u003c\/span\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThere are more valuable reasons why Triplex Aluminium URD is better than copper.\u003c\/p\u003e\n\u003cp\u003eThe reasons are:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli style=\"text-align: left;\"\u003eTriplex Aluminum has been developed to such great extent since its advancement in aluminium alloys in1970.\u003c\/li\u003e\n\u003cli style=\"text-align: left;\"\u003eIt is the best material to use in transmitting electricity.\u003c\/li\u003e\n\u003cli style=\"text-align: left;\"\u003eAluminum is lighter in weight\u003c\/li\u003e\n\u003cli style=\"text-align: left;\"\u003eIt is economical. Low voltage feeders are extensively used by engineers and contractors because it is cheaper than copper.\u003c\/li\u003e\n\u003cli style=\"text-align: left;\"\u003eIt performs equally to copper wire and can be used as an alternative.\u003c\/li\u003e\n\u003cli style=\"text-align: left;\"\u003eIt has same metallic creep as copper\u003c\/li\u003e\n\u003cli style=\"text-align: left;\"\u003eIt is outstanding and withstands any weather condition\u003c\/li\u003e\n\u003cli style=\"text-align: left;\"\u003eIt is designed to be flexible and built for elasticity.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cspan style=\"text-decoration: underline;\"\u003eDo Triplex Aluminium URD building wires take much area than copper?\u003c\/span\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eTriplex aluminium URD does take some area, even though it is lighter and weighs only half the weight than copper wires. They are compressed to bring down the size of diameter to use as an alternative tocopper. Though it takes some area, the important thingto notice is, it offers the greatest flexibility and service life than copper wires.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cspan style=\"text-decoration: underline;\"\u003eIs there a possibility, that during installation the Triplex Aluminium URD cables likely to get damaged?\u003c\/span\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eSince Triplex Aluminium URD cables are lighter in weight than copper, it has lower pulling tension. This protects the cable from getting smudged or smeared during installation.  It can withstand high elongation without any damage. Pulling tensions do not interferewith the performance of the cable. It will not de-laminate even during harsh bends. In some cases, where it has to be pulled, the use of pulling lubricants can reduce damage and lessen pulling tensions.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cspan style=\"text-decoration: underline;\"\u003eDoes duct size matter with each Triplex Aluminium URDcable?\u003c\/span\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eYes, appropriate duct types should be used to increase performance of the cable.\u003c\/p\u003e\n\u003cp\u003eDucting can affect the pulling operation. Duct type should match the internal diameter of the duct to suit the cable. The internal finish of the installed ducting should be even to avoid cable being damaged during installation.  Caution should be exercised while choosing ducts for any Triplex aluminium URD cables.\u003c\/p\u003e","brand":"Nassau National Cable","offers":[{"title":"Default Title","offer_id":27485363011684,"sku":"NNC3145X","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/Con_Hol_Swet.png?v=1762458449","url":"https:\/\/nassaunationalcable.com\/en-ca\/products\/triplex-aluminum-conductor-underground-direct-burial-1350-series-600v-urd-cable","provider":"NassauNationalCable","version":"1.0","type":"link"}