{"product_id":"tp18oslsela-15-18-awg-15-pair-ieee-1580-type-signal-cable-aluminum-armored-300v","title":"TP18(OS)LSELA-15 18 AWG 15 Pair IEEE 1580 Type Signal Cable Aluminum Armored 300V","description":"[short]\n\u003cp\u003e\u003cstrong\u003eTP18(OS)LSELA-15 18 AWG 15 Pair IEEE 1580 Type Signal Cable Aluminum Armored 300V\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eAllowable Ampacity \u003c\/strong\u003efor TP18(OS)LSELA-15 18 AWG 15 Pair IEEE 1580 Type Signal Cable Aluminum Armored 300V:\u003cstrong\u003e 100 Amps\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eAPPLICATIONS:\u003c\/strong\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003eFor use as Signal Cables aboard ship and off-shore oil rigs. The cables are constructed in accordance with the IEEE Recommended Practice for Marine Cable for Use on Shipboard and Fixed or Floating Platforms.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eAlso Known As:\u003cbr\u003e\u003cbr\u003e\u003c\/strong\u003eMarine Tech Cable, LSE Signal Cable, TP18(OS)LSELA-15 Signal Cable, Aluminum Armored Cable, Bronze Armored Cable, Signal Cable, Halogen Free Cable, 300V Signal Cable\u003cstrong\u003e\u003cbr\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCONSTRUCTION:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eCONDUCTOR\u003c\/strong\u003e Soft annealed bare copper per ASTM B 3 and B 8, Class C stranding. Sizes as shown in the attached tables. (tinned copper conductors and Class B stranding available on request)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eINSULATION\u003c\/strong\u003e (Type LSE) Thermosetting, Cross-linked, Low Smoke, Halogen Free, Ethylene Propylene Rubber meeting the IEEE Std 1580-2001 requirements for Type LSE insulation. Wall thickness as shown in attached tables.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTWISTED PAIR COMPONENT\u003c\/strong\u003e (triads available on request) Two conductors twisted together to form a pair. One conductor insulated white with one black. Color code using printed number on each pair.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCOMPONENT SHIELD\u003c\/strong\u003e (optional) Shielded using Aluminum\/Poly tape spirally wrapped in contact with a stranded tinned coated copper drain wire. Drain wire sizes shown in attached tables. Cables with individually shielded components are identified with an “IS” designation.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eASSEMBLY\u003c\/strong\u003e Components cabled together with non-hygroscopic fillers as necessary.\u003c\/li\u003e\n\u003cli\u003eBINDER Cabled assembly helically wrapped with polyester binder tape.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOVERALL SHIELD\u003c\/strong\u003e (optional) Cable shielded using Aluminum\/Poly tape spirally wrapped in contact with a stranded tinned coated copper drain wire. Drain wire sizes shown in attached tables. Cables with an Overall Cable Shield are identified with an “OS” designation.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eJACKET\u003c\/strong\u003e (Type TPO) Flame Retardant, Low Smoke, Halogen Free, Thermoplastic Polyolefin meeting the IEEE Std 1580-2001 requirements for Type TPO jacket. Wall thickness as shown in attached tables.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e       OR\u003cbr\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eJACKET\u003c\/strong\u003e (Type L) Flame Retardant, Low Smoke, Halogen Free, Thermosetting, Cross-linked Polyolefin meeting the IEEE Std 1580-2001 requirements for Type L jacket. Wall thickness as shown in attached tables.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eARMOR\u003c\/strong\u003e (Optional) Aluminum or Bronze Armor Braid available upon request\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eRATINGS:\u003c\/strong\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003ePasses 70,000 BTU\/Hr IEEE-1202, and CSA FT4 Vertical Tray Cable Flame Tests\u003c\/li\u003e\n\u003cli\u003eTemperature Rated at 90°C\u003c\/li\u003e\n\u003cli\u003eMeets all requirements of IEEE Std 1580-2001 for Signal Cable Types LSETPO and LSEL\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eAPPROVALS:\u003c\/strong\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eUL (Underwriters Laboratories) classified Marine Shipboard Cable in Accordance with International Standard IEEE Std 1580-2001.\u003c\/li\u003e\n\u003cli\u003eUL File E319439\u003c\/li\u003e\n\u003cli\u003eABS Type Approval Certificate No.10-HS592905-PDA\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eSpecifications:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eAWG:\u003c\/strong\u003e 18\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eNumber of Pairs:\u003c\/strong\u003e 15\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInsulation Thickness:\u003c\/strong\u003e 0.025 Inches\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eJacket Thickness:\u003c\/strong\u003e 0.080 Inches\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCable Diameter (nominal):\u003c\/strong\u003e 0.93 Inches\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eArmored Cable Diameter (nom):\u003c\/strong\u003e 0.993 Inches\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCable Weight (approx.):\u003c\/strong\u003e 530.25 Lbs\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAluminum Arm.Cable Weight:\u003c\/strong\u003e 551 Lbs\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCable Type:\u003c\/strong\u003e TP18(OS)LSELA-15\u003c\/li\u003e\n\u003c\/ul\u003e\n[\/short]","brand":"Nassau National Cable","offers":[{"title":"Default Title","offer_id":37661686399130,"sku":"","price":0.0,"currency_code":"USD","in_stock":true}],"url":"https:\/\/nassaunationalcable.com\/en-ca\/products\/tp18oslsela-15-18-awg-15-pair-ieee-1580-type-signal-cable-aluminum-armored-300v","provider":"NassauNationalCable","version":"1.0","type":"link"}