{"product_id":"shielded-base-wiring-duct-light-gray-g2x3lg6emi","title":"Shielded Base Wiring Duct Light Gray 6 Ft G2X3LG6EMI","description":"\u003cp\u003e[pdf]\u003cembed type=\"application\/pdf\" height=\"\" width=\"\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/Panduit_1a73dc1f-af16-4150-8eb4-46187274e588.pdf?v=1710479935\"\u003e [\/pdf]\u003c\/embed\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eAbout:\u003cbr\u003e\u003c\/strong\u003e\u003cbr\u003e• Shielded base wiring ducts are designed to provide both mechanical protection and shielding against electromagnetic interference for electrical wires and cables. They help to organize and route cables while minimizing the risk of signal distortion or disruption caused by external electromagnetic fields.\u003cbr\u003e• The ducts are constructed with shielding material, typically made of metal or metal-coated plastics, such as aluminum or conductive polymers. This shielding layer surrounds the wiring channels, effectively containing electromagnetic radiation emitted by the cables and preventing external interference from affecting signal integrity.\u003cbr\u003e• These ducts typically include mounting flanges or adhesive backing for secure installation on walls, ceilings, or other surfaces. Proper grounding of the shielding layer is essential to ensure effective EMI protection.\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003eAlso Known As:\u003cbr\u003e\u003c\/strong\u003e\u003cbr\u003eEMI Shielded Wiring Duct, Shielded Cable Duct, EMC Shielded Wire Duct, Grounded Wiring Duct, Shielded Cable Raceway, Shielded Wire Trough, Shielded Wire Management Channel, Electromagnetic Shielded Cable Tray.\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003eSpecification:\u003c\/strong\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003ctable style=\"width: 74.4526%;\" width=\"100%\"\u003e\n\u003ctbody\u003e\n\u003ctr style=\"height: 19px;\"\u003e\n\u003ctd style=\"width: 33.2117%; text-align: center; height: 19px;\"\u003e\u003cstrong\u003eProduct Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 38.6794%; text-align: center; height: 19px;\"\u003eBase Wiring Duct\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19px;\"\u003e\n\u003ctd style=\"width: 33.2117%; text-align: center; height: 19px;\"\u003e\u003cstrong\u003eMaterial\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 38.6794%; text-align: center; height: 19px;\"\u003ePVC\/Aluminum\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19px;\"\u003e\n\u003ctd style=\"width: 33.2117%; text-align: center; height: 19px;\"\u003e\u003cstrong\u003eColor\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 38.6794%; text-align: center; height: 19px;\"\u003e Light Gray\u003cbr\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19px;\"\u003e\n\u003ctd style=\"width: 33.2117%; text-align: center; height: 19px;\"\u003e\u003cstrong\u003eMeasurement System\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 38.6794%; text-align: center; height: 19px;\"\u003eImperial\u003cbr\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19px;\"\u003e\n\u003ctd style=\"width: 33.2117%; text-align: center; height: 19px;\"\u003e\u003cstrong\u003eWidth\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 38.6794%; text-align: center; height: 19px;\"\u003e 2.25 in\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19px;\"\u003e\n\u003ctd style=\"width: 33.2117%; text-align: center; height: 19px;\"\u003e\u003cstrong\u003eLength\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 38.6794%; text-align: center; height: 19px;\"\u003e 6 ft\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 39px;\"\u003e\n\u003ctd style=\"width: 33.2117%; text-align: center; height: 39px;\"\u003e\u003cstrong\u003eMount Method\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 38.6794%; text-align: center; height: 39px;\"\u003e Mounting Holes\u003cbr\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19px;\"\u003e\n\u003ctd style=\"width: 33.2117%; text-align: center; height: 19px;\" class=\"pl-2 border-all table-column-width border-block pdt-td-border-top\"\u003e\u003cstrong\u003e\u003cspan\u003eWiring Duct Type\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 38.6794%; text-align: center; height: 19px;\"\u003eG\u003cbr\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 58px;\"\u003e\n\u003ctd style=\"width: 33.2117%; text-align: center; height: 58px;\"\u003e\u003cstrong\u003eStandards Met\u003cbr\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 38.6794%; text-align: center; height: 58px;\"\u003e\n\u003cbr\u003eRoHS Compliant, UL Recognized, CE Compliant\u003cbr\u003e\u003cbr\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 39px;\"\u003e\n\u003ctd style=\"width: 33.2117%; text-align: center; height: 39px;\"\u003e\u003cstrong\u003eWiring Duct Style\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 38.6794%; text-align: center;\" class=\"pl-2 border-all border-block\"\u003eShielded Wiring Duct\u003cbr\u003e\u003cbr\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19px;\"\u003e\n\u003ctd style=\"width: 33.2117%; text-align: center; height: 19px;\"\u003e\u003cstrong\u003ePart No.\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 38.6794%; text-align: center; height: 19px;\"\u003e G2X3LG6EMI\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cbr\u003eFeatures:\u003c\/strong\u003e\u003cbr\u003e\u003cbr\u003e• Two channel wiring duct with a hinged and flexible cover that allows you to mount DIN rail and components on top of the duct to maximize space.\u003cbr\u003e• Up to 30% panel space savings, up to 25% material cost savings and up to 50% faster installation.\u003cbr\u003e• Pass-through holes to shorten the wire path.\u003cbr\u003e• Metric sizing and finger progression.\u003cbr\u003e• Duct and cover packaged together in 2 m L.\u003cbr\u003e• High continuous use temperature.\u003cbr\u003e• The base sidewall is even with cover for superior aesthetics and greater wiring capacity when compared to non-flush cover wiring duct.\u003cbr\u003e• Base and finger score lines.\u003cbr\u003e\u003c\/p\u003e","brand":"Panduit","offers":[{"title":"Default Title","offer_id":44551423721626,"sku":"G2X3LG6EMI","price":343.17,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/5_7cb075fa-4269-41f1-9500-baf47217143c.png?v=1762992921","url":"https:\/\/nassaunationalcable.com\/en-ca\/products\/shielded-base-wiring-duct-light-gray-g2x3lg6emi","provider":"NassauNationalCable","version":"1.0","type":"link"}