{"product_id":"okoguard-stranded-aluminum-shielded-epr-okoseal-pvc-mv-105-5kv-133-8kv-100-power-cable","title":"Okoguard Stranded Aluminum Shielded EPR Okoseal PVC MV-105 5KV-133% 8KV-100% Power Cable","description":"\u003cp\u003e[pdf] \u003cembed src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/2-61.pdf?v=1712743156\"\u003e [\/pdf]\u003c\/embed\u003e\u003c\/p\u003e\n\u003ch4 data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003eAbout:\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cp data-mce-fragment=\"1\"\u003eThis cable is designed for medium voltage applications, featuring an ethylene propylene rubber (EPR) insulation, which provides excellent electrical insulation properties, and a polyvinyl chloride (PVC) jacket that offers durability and resistance to various environmental factors. The 'MV-105' designation indicates its suitability for medium voltage applications up to 105°C, while '5KV-133%' and '8KV-100%' refer to its electrical stress withstand capabilities at 5 kilovolts and 8 kilovolts, respectively.\u003c\/p\u003e\n\u003ch4 data-mce-fragment=\"1\"\u003e\n\u003cstrong data-mce-fragment=\"1\"\u003eAlso K\u003c\/strong\u003e\u003cstrong data-mce-fragment=\"1\"\u003enown As:\u003c\/strong\u003e\n\u003c\/h4\u003e\n\u003cp data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003e•\u003c\/strong\u003e\u003cspan data-mce-fragment=\"1\"\u003e EPR Insulated PVC Jacketed Cable\u003cbr data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003e•\u003c\/strong\u003e Aluminum Conductor Medium Voltage Cable\u003cbr data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003e•\u003c\/strong\u003e 5KV\/8KV Shielded Power Cable\u003c\/span\u003e\u003c\/p\u003e\n\u003ch4 data-mce-fragment=\"1\"\u003e\u003cspan data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003eApplications:\u003c\/strong\u003e\u003c\/span\u003e\u003c\/h4\u003e\n\u003cp data-mce-fragment=\"1\"\u003e\u003cspan data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003e• \u003c\/strong\u003eOkoguard shielded Okoseal Type MV-105 power cables are recommended for use as feeder circuits, in electric utility generating stations, for distribution circuits, and for feeders or branch circuits in industrial and commercial installations.\u003cbr data-mce-fragment=\"1\"\u003e\u003cstrong\u003e•\u003c\/strong\u003e Type MV cables may be installed in wet or dry locations, indoors or outdoors  (exposed to sunlight), in any raceway or underground duct, directly buried if installed in a system with a grounding conductor in close proximity that conforms with NEC Section 315.36 and 250.4(A)(5), or messenger supported in industrial establishments and electric utilities.\u003cbr data-mce-fragment=\"1\"\u003e\u003cstrong\u003e•\u003c\/strong\u003e Sizes 1\/0 AWG and larger may also be installed in cable tray as permitted by NEC Section 315.32(3).\u003c\/span\u003e\u003c\/p\u003e\n\u003ch4 data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003eStandards:\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cp data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003e•\u003c\/strong\u003e IEEE 404: Standard for extruded and laminated dielectric shielded cable joints.\u003cbr data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003e•\u003c\/strong\u003e ICEA S-93-639\/NEMA WC 74: For 5-35 kV shielded power cables.\u003cbr data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003e•\u003c\/strong\u003e UL 1072: Standard for medium voltage power cables, ensuring they meet certain fire resistance and safety criteria.\u003c\/p\u003e\n\u003ch4 data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003eConstruction:\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cp data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003e• Conductor:\u003c\/strong\u003e Aluminum per ASTM B-609, Class B Stranded per B-231.\u003cstrong data-mce-fragment=\"1\"\u003e\u003cbr data-mce-fragment=\"1\"\u003e• Strand Screen:\u003c\/strong\u003e\u003cspan data-mce-fragment=\"1\"\u003e Extruded EPR semiconducting strand screen. Meets or exceeds electrical and physical requirements of ICEA S-93-639\/NEMA WC74 \u0026amp; S-97-682, AEIC CS8, CSA C68.10 and UL 1072\u003c\/span\u003e\u003cstrong data-mce-fragment=\"1\"\u003e\u003cbr data-mce-fragment=\"1\"\u003e• Insulation:\u003c\/strong\u003e Meets or exceeds electrical and physical requirements of ICEA S-93- 639\/NEMA WC74 \u0026amp; S-97-682, AEIC CS8, CSA C68.10 and UL 1072.\u003cstrong data-mce-fragment=\"1\"\u003e\u003cbr data-mce-fragment=\"1\"\u003e• Insulation Screen:\u003c\/strong\u003e Extruded EPR semiconducting insulation screen applied directly over the insulation. Meets or exceeds electrical and physical requirements of ICEAS-93 639\/NEMA WC74 \u0026amp; S-97-682, AEIC CS8, CSA C68.10 and UL 1072.\u003cstrong data-mce-fragment=\"1\"\u003e\u003cbr data-mce-fragment=\"1\"\u003e• Shield:\u003c\/strong\u003e 5 mil bare copper tape helically applied with 25% minimum overlap.\u003cstrong data-mce-fragment=\"1\"\u003e\u003cbr data-mce-fragment=\"1\"\u003e• Jacket:\u003c\/strong\u003e Meets or exceeds electrical and physical requirements of ICEA S-93- 639\/NEMA WC74 \u0026amp; S-97-682, CSA C68.10 and UL 1072 for polyvinyl chloride jackets.\u003cbr\u003eUL listed as Type MV-105, sunlight resistant, and for use in cable tray in accordance with UL 1072.\u003cbr data-mce-fragment=\"1\"\u003eCSA C68.10 listed as FT4, SR, LTGG (-40°C), TC (\u0026lt; 500 kcmil) and TC-ER (≥ 500 kcmil).\u003cbr\u003e\u003c\/p\u003e\n\u003ch4 data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003eFeatures:\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cp data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003e• \u003c\/strong\u003eTriple tandem extruded, all EPR system.\u003cbr data-mce-fragment=\"1\"\u003e\u003cstrong\u003e•\u003c\/strong\u003e Okoguard cables meet or exceed all recognized industry standards (UL, CSA, AEIC, NEMA\/ICEA, IEEE).\u003cbr data-mce-fragment=\"1\"\u003e\u003cstrong\u003e•\u003c\/strong\u003e 105°C continuous operating temperature.\u003cbr data-mce-fragment=\"1\"\u003e\u003cstrong\u003e•\u003c\/strong\u003e 140°C emergency rating.\u003cbr data-mce-fragment=\"1\"\u003e\u003cstrong\u003e•\u003c\/strong\u003e 250°C short circuit rating.\u003cbr data-mce-fragment=\"1\"\u003e\u003cstrong\u003e•\u003c\/strong\u003e Passes the Vertical Tray Flame Test requirements of UL 1072 and IEEE 383 and 1202.\u003cbr data-mce-fragment=\"1\"\u003e\u003cstrong\u003e•\u003c\/strong\u003e Excellent corona resistance.\u003cbr data-mce-fragment=\"1\"\u003e\u003cstrong\u003e•\u003c\/strong\u003e Screens are clean stripping.\u003cbr data-mce-fragment=\"1\"\u003e\u003cstrong\u003e•\u003c\/strong\u003e Exceptional resistance to \"treeing\".\u003cbr data-mce-fragment=\"1\"\u003e\u003cstrong\u003e•\u003c\/strong\u003e Exceptional resistance to moisture.\u003cbr data-mce-fragment=\"1\"\u003e\u003cstrong\u003e•\u003c\/strong\u003e Resistant to most oils, acids, and alkalies.\u003cbr data-mce-fragment=\"1\"\u003e\u003cstrong\u003e•\u003c\/strong\u003e Sunlight resistant.\u003cbr data-mce-fragment=\"1\"\u003e\u003cstrong\u003e•\u003c\/strong\u003e For Cable Tray Use.\u003cbr data-mce-fragment=\"1\"\u003e\u003cstrong\u003e•\u003c\/strong\u003e Improved Temperature Rating.\u003cbr data-mce-fragment=\"1\"\u003e\u003cstrong\u003e•\u003c\/strong\u003e Compact constructions available upon special request.\u003c\/p\u003e","brand":"okonite","offers":[{"title":"Default Title","offer_id":44692790935706,"sku":"","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/5_d5cce328-ad74-403f-8c16-4a106e5ce823.png?v=1759827755","url":"https:\/\/nassaunationalcable.com\/en-ca\/products\/okoguard-stranded-aluminum-shielded-epr-okoseal-pvc-mv-105-5kv-133-8kv-100-power-cable","provider":"NassauNationalCable","version":"1.0","type":"link"}