{"product_id":"okoguard-okoseal-type-mv-105-175-mils-1","title":"OKOGUARD OKOSEAL TYPE MV-105 - 175 MILS","description":"\u003cp\u003e\u003cstrong\u003eApplications\u003cbr\u003e\u003c\/strong\u003e\u003cbr\u003e Okoguard shielded three conductor Okoseal Type MV-105 power cables are recommended for distribution circuits, and for feeders or branch circuits in industrial and utility power distribution systems. Type MV cables may be installed in wet or dry locations, indoors or outdoors (exposed to sunlight), in industrial establishments and electric utilities, residential and commercial applications and others. An excellent alternative where aesthetics and clearances are an issue.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eInsulation\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eOkoguard is Okoniteâ€™s registered trade name for its exclusive ethylene-propylene rubber (EPR) based, thermosetting compound, whose optimum balance of electrical and physical properties is unequaled in other solid dielectrics.\u003cbr\u003e Okoguard insulation, with the distinctive red color and a totally integrated EPR system, provides the optimum balance of electrical and physical properties for long, problem free service.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eJacket\u003cbr\u003e\u003c\/strong\u003e\u003cbr\u003e The Okoseal (PVC) jacket supplied with this cable is mechanically rugged and has excellent resistance to oil and most chemicals\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eAssembly\u003cbr\u003e\u003c\/strong\u003e\u003cbr\u003e Three 1\/C Class B stranded copper conductors, triple tandem extruded, semiconducting EPR strand screen - Okoguard EPR insulation - extruded semiconducting EPR insulation screen, shielding tape and an overall jacket. Three single conductors are cabled together and laid parallel to a copper clad steel messenger. The messenger and triplexed assembly are bound together with a PE coated copper or stainless steel strap.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003e\u003c\/strong\u003e\u003cstrong\u003eSpecfications\u003cbr\u003e\u003c\/strong\u003e\u003cbr\u003e \u003cstrong\u003eConductor:\u003c\/strong\u003e Uncoated copper compact stranded per ASTM B-496.\u003cbr\u003e \u003cstrong\u003eStrand Screen:\u003c\/strong\u003e Extruded semiconducting EPR strand screen meets or exceeds electrical and physical requirements of ICEA S-93-639\/NEMA WC74 and UL 1072, AEIC CS8\/ICEA S-97-682.\u003cbr\u003e \u003cstrong\u003eInsulation:\u003c\/strong\u003e Okoguard meets or exceeds the electrical and physical requirements of ICEA S-93-639\/NEMA WC74 and UL 1072. The insulated conductors are tested in accordance with AEIC CS8\/ICEA S-97-682.\u003cbr\u003e \u003cstrong\u003eInsulation Screen:\u003c\/strong\u003e Extruded semiconducting EPR insulation screen per ICEA S-93-639\/NEMA WC74, AEIC CS8\/ICEA S-97-682 and UL 1072.\u003cbr\u003e \u003cstrong\u003eSheild:\u003c\/strong\u003e 5 mil uncoated copper tape helically applied with 12.5% nominal overlap. \u003cbr\u003e \u003cstrong\u003eJacket:\u003c\/strong\u003e Meets or exceeds electrical and physical requirements of ICEA S-93-639\/NEMA WC74, AEIC CS8\/ICEA S-97-682 \u0026amp; UL 1072 for polyvinyl chloride jackets. UL listed as Type MV-105 and sunlight resistant in accordance with UL 1072.\u003cbr\u003e \u003cstrong\u003eCopperweld Messenger:\u003c\/strong\u003e Copper-clad steel stranded conductor per ASTM B228, and sized in accordance with ICEA P-79-561 for 150 ft. spans.\u003cbr\u003e \u003cstrong\u003eAssembly:\u003c\/strong\u003e Three single conductors are cabled together and laid parallel to a copper clad steel messenger.\u003cbr\u003e \u003cstrong\u003eBinder Strap:\u003c\/strong\u003e A sunlilght resistant polyethylene (PE) jacketed binder strap with an open lay is wound around the assembly to hold the messenger parallel to the cable axis.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eProduct Features\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eTriple tandem extruded, all EPR system.\u003c\/li\u003e\n\u003cli\u003eComplete assembled, factory tested wiring system.\u003c\/li\u003e\n\u003cli\u003ePasses the UL 1072 requirements.\u003c\/li\u003e\n\u003cli\u003eExcellent corona resistance.\u003c\/li\u003e\n\u003cli\u003eScreens are clean stripping.\u003c\/li\u003e\n\u003cli\u003eExceptional resistance to â€œtreeingâ€.\u003c\/li\u003e\n\u003cli\u003eImproved temperature rating.\u003c\/li\u003e\n\u003cli\u003eMinimum installation temperature of -10Â°C (14Â°F).\u003c\/li\u003e\n\u003cli\u003eThe standard messenger is copper-clad steel. Also available, upon request, are galvanized steel and stainless steel.\u003c\/li\u003e\n\u003cli\u003eAdditional voltage classes are available.\u003c\/li\u003e\n\u003cli\u003eTree trimming requirements reduced.\u003c\/li\u003e\n\u003cli\u003eClearance levels reduced due to the use of insulated conductors.\u003c\/li\u003e\n\u003cli\u003eEases right-of-way requirements.\u003c\/li\u003e\n\u003cli\u003eDifferent size messengers available for different span lengths\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e \u003c\/p\u003e","brand":"Nassau National Cable","offers":[{"title":"Default Title","offer_id":27838254809188,"sku":"NNC33305X","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/products\/okoguard.jpg?v=1762478164","url":"https:\/\/nassaunationalcable.com\/en-ca\/products\/okoguard-okoseal-type-mv-105-175-mils-1","provider":"NassauNationalCable","version":"1.0","type":"link"}